Jump to content

Extracted text: The-International-System-of-Units-(SI),-9th-Edition-(Document).pdf

Markdown text generated by Apache Tika. Review it before citing; OCR may contain errors. View the PDF · File:The-International-System-of-Units-(SI),-9th-Edition-(Document).extracted.txt
SI Brochure - 9th ed./version 4.01 EN  

——————————————————————————

Bureau International

des Poids et Mesures

The International System of Units

(SI)

9th edition 2019

————————————————

[https://doi.org/10.59161/AUEZ1291](https://doi.org/10.59161/AUEZ1291)

V4.01

June 2026

[https://doi.org/10.59161/AUEZ1291](https://doi.org/10.59161/AUEZ1291)

# Copyright statement

The SI Brochure is distributed under the terms of the Creative Commons Attribution 4.0  International License ([http://creativecommons.org/licenses/by/4.0/](http://creativecommons.org/licenses/by/4.0/)), which permits unrestricted  use, distribution, and reproduction in any medium, provided you give appropriate credit to the  original author(s) and the source, provide a link to the Creative Commons license, and indicate  if changes were made.

Published by the BIPM,

Pavillon de Breteuil,

F-92312 Sèvres Cedex

France

ISBN 978-92-822-2272-0

[http://creativecommons.org/licenses/by/4.0/](http://creativecommons.org/licenses/by/4.0/)

# The BIPM  and the Metre Convention

The International Bureau of Weights and Measures (BIPM) was set up by the Metre  Convention signed in Paris on 20 May 1875 by seventeen States during the final session of  the diplomatic Conference of the Metre. This Convention was amended in 1921.

The BIPM has its headquarters near Paris, in the grounds (43 520 m2) of the Pavillon de  Breteuil (Parc de Saint-Cloud) placed at its disposal by the French Government; its upkeep  is financed jointly by the Member States of the Metre Convention.

The task of the BIPM is to ensure worldwide unification of measurements; its objectives are  to:

## • represent the world-wide measurement community, aiming to maximize its uptake and  impact,

## • be a centre for scientific and technical collaboration between Member States, providing  capabilities for international measurement comparisons on a shared-cost basis,

## • be the coordinator of the world-wide measurement system, ensuring it gives comparable  and internationally accepted measurement results.

The BIPM operates under the exclusive supervision of the International Committee for  Weights and Measures (CIPM) which itself comes under the authority of the General  Conference on Weights and Measures (CGPM) and reports to it on the work accomplished  by the BIPM.

Delegates from all Member States attend the General Conference, which normally meets  every four years. The function of these meetings is to:

## • discuss and initiate the arrangements required to ensure the propagation and  improvement of the International System of Units (SI), which is the modern form of the  metric system;

## • confirm the results of new fundamental metrological determinations and various  scientific resolutions of international scope;

## • take all major decisions concerning the finance, organization and development of the  BIPM.

The CIPM has eighteen members each from a different State: at present, it meets every year.  The officers of this committee present an annual report on the administrative and financial  position of the BIPM to the Governments of the Member States. The principal task of the  CIPM is to ensure worldwide uniformity in units of measurement. It does this by direct action  or by submitting proposals to the CGPM.

The BIPM and the Metre Convention  •  113

The activities of the BIPM, which in the beginning were limited to measurements of length  and mass, and to metrological studies in relation to these quantities, have been extended to  standards of measurement of electricity (1927), photometry and radiometry (1937), ionizing  radiation (1960), time scales (1988) and to chemistry (2000). To this end the original  laboratories, built in 1876 -1878, were enlarged in 1929; new buildings were constructed in  1963-1964 for the ionizing radiation laboratories, in 1984 for the laser work and in 1988 for  a library and offices. In 2001 a new building for the workshop, offices and meeting rooms  was opened.

Some forty-five physicists and technicians work in the BIPM laboratories. They mainly  conduct metrological research, international comparisons of realizations of units and  calibrations of standards. An annual Director’s report gives details of the work in progress.

Following the extension of the work entrusted to the BIPM in 1927, the CIPM has set up  bodies, known as Consultative Committees, whose function is to provide it with information  on matters that it refers to them for study and advice. These Consultative Committees, which  may form temporary or permanent working groups to study special topics, are responsible  for coordinating the international work carried out in their respective fields and for proposing  recommendations to the CIPM concerning units.

The Consultative Committees have common regulations (Document CIPM-D-01, Rules of  procedure for the Consultative Committees (CCs) created by the CIPM, CC working groups  and CC workshops). They meet at irregular intervals. The president of each Consultative  Committee is designated by the CIPM and is normally a member of the CIPM. The members  of the Consultative Committees are metrology laboratories and specialized institutes, agreed  by the CIPM, which send delegates of their choice. In addition, there are individual members  appointed by the CIPM, and a representative of the BIPM (Document CIPM-D-01, Rules of  procedure for the Consultative Committees (CCs) created by the CIPM, CC working groups  and CC workshops). At present, there are ten such committees:

1\. The Consultative Committee for Electricity and Magnetism (CCEM), new name given  in 1997 to the Consultative Committee for Electricity (CCE) set up in 1927;

2\. The Consultative Committee for Photometry and Radiometry (CCPR), new name given  in 1971 to the Consultative Committee for Photometry (CCP) set up in 1933 (between  1930 and 1933 the CCE dealt with matters concerning photometry);

3\. The Consultative Committee for Thermometry (CCT), set up in 1937;

4\. The Consultative Committee for Length (CCL), new name given in 1997 to the  Consultative Committee for the Definition of the Metre (CCDM), set up in 1952;

5\. The Consultative Committee for Time and Frequency (CCTF), new name given in 1997  to the Consultative Committee for the Definition of the Second (CCDS) set up in 1956;

6\. The Consultative Committee for Ionizing Radiation (CCRI), new name given in 1997 to  the Consultative Committee for Standards of Ionizing Radiation (CCEMRI) set up in  1958 (in 1969 this committee established four sections: Section I (X- and γ-rays,  electrons), Section II (Measurement of radionuclides), Section III (Neutron  measurements), Section IV (α-energy standards); in 1975 this last section was dissolved  and Section II was made responsible for its field of activity);

7\. The Consultative Committee for Units (CCU), set up in 1964 (this committee replaced  the Commission for the System of Units set up by the CIPM in 1954);

114  •  The BIPM and the Metre Convention

8\. The Consultative Committee for Mass and Related Quantities (CCM), set up in 1980;

9\. The Consultative Committee for Amount of Substance: Metrology in Chemistry and  Biology (CCQM), set up in 1993;

10\. The Consultative Committee for Acoustics, Ultrasound and Vibration (CCAUV), set up  in 1999.

The proceedings of the General Conference and the CIPM are published by the BIPM in the  following series:

## • Report of the meeting of the General Conference on Weights and Measures;

## • Report of the meeting of the International Committee for Weights and Measures.

The CIPM decided in 2003 that the reports of meetings of the Consultative Committees  should no longer be printed, but would be placed on the BIPM website, in their original  language.

The BIPM also publishes monographs on special metrological subjects and, under the title  The International System of Units (SI), a brochure, periodically updated, in which are  collected all the decisions and recommendations concerning units.

The collection of the Travaux et Mémoires du Bureau International des Poids et Mesures  (22 volumes published between 1881 and 1966) and the Recueil de Travaux du Bureau  International des Poids et Mesures (11 volumes published between 1966 and 1988) ceased  by a decision of the CIPM.

The scientific work of the BIPM is published in the open scientific literature.

Since 1965 Metrologia, an international journal published under the auspices of the CIPM,  has printed articles dealing with scientific metrology, improvements in methods of  measurement, work on standards and units, as well as reports concerning the activities,  decisions and recommendations of the various bodies created under the Metre Convention.

The BIPM and the Metre Convention  •  115

# The International System of Units Contents

Preface to the 9th edition    118

1 Introduction     121

1\.1 The SI and the defining constants   121

1\.2 Motivation for the use of defining constants to define the SI 121

1\.3 Implementation of the SI  122

2 The International System of Units   123

2\.1 Defining the unit of a quantity   123

2\.2 Definition of the SI   123

2\.2.1 The nature of the seven defining constants  124

2\.3 Definitions of the SI units   125

2\.3.1 Base units   126

2\.3.2 Practical realization of SI units  131

2\.3.3 Dimensions of quantities  132

2\.3.4 Derived units   133

2\.3.5 Units for quantities that describe biological and   137

physiological effects

2\.3.6 SI units in the framework of the general theory of relativity 137

3 Decimal multiples and sub-multiples of SI units   138

4 Non-SI units    140

5 Writing unit symbols and names, and expressing the values of quantities 142

5\.1 The use of unit symbols and names   142

5\.2 Unit symbols   142

5\.3 Unit names   143

5\.4 Rules and style conventions for expressing values of quantities 143

5\.4.1 Value and numerical value of a quantity, and the use  143

of quantity calculus

5\.4.2 Quantity symbols and unit symbols   144

5\.4.3 Formatting the value of a quantity  144

5\.4.4 Formatting numbers, and the decimal marker  145

5\.4.5 Expressing the measurement uncertainty in the value 145

of a quantity

5\.4.6 Multiplying or dividing quantity symbols, the values  146

of quantities, or numbers

5\.4.7 Quantities with the unit one  146

116  •  Contents

Appendix 1.  Decisions of the CGPM and the CIPM  147

Appendix 2.  Practical realization of the definitions of some 198

important units

Appendix 3.  Units for photochemical and photobiological  199

quantities

Appendix 4.  Historical notes on the development of the   200

International System of Units and its base units

Part 1. The historical development of the realization of SI units 200

Part 2. The historical development of the International System 202

Part 3. Historical perspective on the base units  204

List of acronyms 209

Contents  •  117

# Preface  to the 9th edition

# The International System of Units, the SI, has been used around the world as the preferred  system of units, the basic language for science, technology, industry and trade since it was  established in 1960 by a resolution at the 11th meeting of the Conférence Générale des Poids  et Mesures, the CGPM (known in English as the General Conference on Weights and  Measures).

# This brochure is published by the Bureau International des Poids et Mesures, the BIPM  (known in English as the International Bureau of Weights and Measures) to promote and  explain the SI. It lists the most significant Resolutions of the CGPM and decisions of the  Comité International des Poids et Mesures, the CIPM (known in English as the International  Committee on Weights and Measures) that concern the metric system going back to the 1st  meeting of the CGPM in 1889.

# The SI has always been a practical and dynamic system that has evolved to exploit the latest  scientific and technological developments. In particular, the tremendous advances in atomic  physics and quantum metrology made over the last 50 years have enabled the definitions of  the second, the metre, and the practical representation of the electrical units to take advantage  of atomic and quantum phenomena to achieve levels of accuracy for realizing the respective  units limited only by our technical capability and not by the definitions themselves. These  advances in science together with developments in measurement technology have enabled  changes to the SI which have been promoted and explained in the previous editions of this  brochure.

# This 9th edition of the SI brochure has been prepared following the adoption by the  26th meeting of the CGPM of a set of far-reaching changes. The meeting introduced a new  approach to articulating the definitions of the units in general, and of the seven base units in  particular, by fixing the numerical values of seven “defining” constants. Among them are  fundamental constants of nature such as the Planck constant and the speed of light, so that  the definitions are based on and represent our present understanding of the laws of physics.  For the first time, a complete set of definitions is available that does not make reference to  any artefact standards, material properties or measurement descriptions. These changes  enable the realization of all units with an accuracy that is ultimately limited only by the  quantum structure of nature and our technical abilities but not by the definitions themselves.  Any valid equation of physics relating the defining constants to a unit can be used to realize  the unit thus creating opportunities for innovation, realization everywhere with increasing  accuracy as technology proceeds. Thus, this redefinition marks a significant and historic step  forward.

# The changes were agreed by the CGPM in November 2018 with effect from May 20th 2019,  a date chosen because it is World Metrology Day, the day when the Metre Convention was  signed in 1875. Whilst the future impact of the changes will be far reaching, great attention  has been paid to ensure that these definitions are consistent with those in place at the time the  change was implemented.

118  •  Preface

# We draw attention to the fact that since its establishment in 1960, the International System  of Units has always been referred to as “the SI” in its shortened form. This principle has been  maintained in the eight previous editions of this brochure and was reaffirmed in Resolution  1 adopted at the 26th meeting of the CGPM, which also confirmed that the title of this  brochure is simply “The International System of Units”. This consistency of reference to the  SI reflects the efforts of the CGPM and the CIPM to ensure the continuity of the values of  measurements expressed in SI units through each change that has been made.

# The text of this brochure has been prepared in order to provide a full description of the SI  and to provide some historical background. It also has four appendices:

# Appendix 1 reproduces, in chronological order, all of the decisions (Resolutions,  Recommendations, Declarations) promulgated since 1889 by the CGPM and the CIPM  on units of measurement and the International System of Units.

# Appendix 2 is only available in an electronic version (www.bipm.org). It outlines the  practical realization of the seven base units and other important units in each field. This  appendix will be updated regularly to reflect improvements in the experimental  techniques available for realizing the units.

# Appendix 3 is only available in an electronic version (www.bipm.org). It discusses units  for photochemical and photobiological quantities.

# Appendix 4 provides some notes on the history of the development of the SI.

# We conclude by expressing our thanks to the members of the Comité Consultatif des Unités  of the CIPM, the CCU (known in English as the Consultative Committee for Units), who  were responsible for drafting this brochure. Both the CCU and the CIPM have approved the  final text.

March 2019

||
|---|
||

B. Inglis

President, CIPM

J. Ullrich

President, CCU

M.J.T. Milton

Director, BIPM

Preface  •  119

120 ¢ Preface  Preface to version 4.01 of the 9th edition  The move to digital publishing has made it simpler for updates to the SI Brochure to be made without issuing a new edition. In most cases these simply correct typographical errors or improve formatting, and the CCU President and Executive Secretary will continue to implement such editorial changes that improve the text of the SI Brochure without affecting its meaning. Larger improvements or technical changes result in the production of a new version of the current edition. Since the 9th edition was first published in 2019, three new versions have been produced.  In 2022, version 2.01 of the 9th edition was published. This updated version contained the new SI prefixes adopted by the CGPM at its 27th meeting in November 2022.  In 2024, version 3.01 of the 9th edition was published. This updated version contained improvements to the descriptions of angle and quantities with the unit one. A minor update, version 3.02, was published in August 2025 to revise the value of the dalton, update the list of binary prefixes, and implement small editorial improvements.  In 2026, version 4.01 of the 9th edition was published. This updated version contained a revised description of the relationship between widely used non-SI units and the SI. Additionally, the marginal notes of previous versions were incorporated into the main text and the index deleted.  June 2026 W. Louw R.J.C. Brown A. Koo President, CIPM President, CCU Director, BIPM  Note on the text  The 22nd meeting of the CGPM decided, in 2003, following a decision of the CIPM in 1997, that “the symbol for the decimal marker shall be either the point on the line or the comma on the line”. Following this decision, and following custom in the two languages, in this edition the point on the line is used as a decimal marker in the English text, and a comma on the line is used in the French text. This has no implication for the translation of the decimal marker into other languages. Small spelling variations occur in the language of the English-speaking countries (for instance, “metre” and “meter”, “litre” and “liter”). In this respect, the English text presented here follows the ISO/IEC 80000 series Quantities and units. However, the symbols for SI units used in this brochure are the same in all languages.  Readers should note that the official record of the meetings of the CGPM and the sessions of the CIPM is that of the French text. This brochure provides the text in English, but when an authoritative reference is required or when there is doubt about the interpretation of the text the French should be used. 

### 1  Introduction

1\.1  The SI and the defining constants

This brochure presents information on the definition and use of the International System of  Units, universally known as the SI (from the French Système international d’unités), for  which the General Conference on Weights and Measures (CGPM) has responsibility. In 1960  the 11th CGPM formally defined and established the SI and has subsequently revised it from  time to time in response to the requirements of users and advances in science and technology.  The most recent and perhaps the most significant revision of the SI since its establishment  was made by the 26th CGPM (2018) and is documented in this 9th edition of the SI Brochure.  The Metre Convention and its organs, the CGPM, the Comité International des Poids et  Mesures (CIPM), the Bureau International des Poids et Mesures (BIPM), and the  Consultative Committees are described in the text “The BIPM and the Metre Convention” on  page 113.

The SI is a consistent system of units for use in all aspects of life, including international  trade, manufacturing, security, health and safety, protection of the environment, and in the  basic science that underpins all of these. The system of quantities underlying the SI and the  equations relating them are based on the present description of nature and are familiar to all  scientists, technologists and engineers.

The definition of the SI units is established in terms of a set of seven defining constants. The  complete system of units can be derived from the fixed values of these defining constants,  expressed in the units of the SI. These seven defining constants are the most fundamental  feature of the definition of the entire system of units. These particular constants were chosen  after having been identified as being the best choice, taking into account the previous  definition of the SI, which was based on seven base units, and progress in science.

A variety of experimental methods described by the CIPM Consultative Committees may be  used to realize the definitions. Descriptions of these realizations are also referred to as “mises  en pratique”. Realizations may be revised whenever new experiments are developed; for this  reason advice on realizing the definitions is not included in this brochure but is available on  the BIPM website.

1\.2  Motivation for the use of defining constants to define the SI

Historically, SI units have been presented in terms of a set of – most recently seven – base  units. All other units, described as derived units, are constructed as products of powers of the  base units.

Different types of definitions for the base units have been used: specific properties of artefacts  such as the mass of the international prototype for the unit kilogram; a specific physical state  such as the triple point of water for the unit kelvin; idealized experimental prescriptions as in  the case of the ampere and the candela; or constants of nature such as the speed of light for  the definition of the unit metre.

Introduction  •  121

To be of any practical use, these units not only have to be defined, but they also have to be  realized physically for dissemination. In the case of an artefact, the definition and the  realization are equivalent – a path that was pursued by advanced ancient civilizations.  Although this is simple and clear, artefacts involve the risk of loss, damage or change.  The other types of unit definitions are increasingly abstract or idealized. Here, the realizations  are separated conceptually from the definitions so that the units can, as a matter of principle,  be realized independently at any place and at any time. In addition, new and superior  realizations may be introduced as science and technologies develop, without the need to  redefine the unit. These advantages – most obviously seen with the history of the definition  of the metre from artefacts through an atomic reference transition to the fixed numerical value  of the speed of light – led to the decision to define all units by using defining constants.

The choice of the base units was never unique, but grew historically and became familiar to  users of the SI. This description in terms of base and derived units is maintained in the present  definition of the SI, but has been reformulated as a consequence of adoption of the defining  constants.

1\.3  Implementation of the SI

The definitions of the SI units, as decided by the CGPM, represent the highest reference level  for measurement traceability to the SI.

Metrology institutes around the world establish the practical realizations of the definitions in  order to allow for traceability of measurements to the SI. The Consultative Committees  provide the framework for establishing the equivalence of the realizations in order to  harmonize traceability world-wide.

Standardization bodies may specify further details for quantities and units and rules for their  application, where these are needed by interested parties. Whenever SI units are involved,  these standards must refer to the definitions by the CGPM. Many such specifications are  listed for example in the standards developed by the International Organization for  Standardization and the International Electrotechnical Commission (ISO/IEC 80000 series  of international standards).

Individual countries have established rules concerning the use of units by national legislation,  either for general use or for specific areas such as commerce, health, public safety and  education. In almost all countries, this legislation is based on the SI. The International  Organization of Legal Metrology (OIML) is charged with the international harmonization of  the technical specifications of this legislation.

122  •  Introduction

### 2  The International System of Units

2\.1 Defining the unit of a quantity

The value of a quantity is generally expressed as the product of a number and a unit. The unit  is a particular example of the quantity concerned which is used as a reference, and the number  is the ratio of the value of the quantity to the unit. For example, the speed of light in vacuum  is a constant of nature, denoted by c, whose value in SI units is given by the relation  c = 299 792 458 m/s where the numerical value is 299 792 458 and the unit is m/s.

For a particular quantity different units may be used. For example, the value of the speed v  of a particle may be expressed as v = 25 m/s or v = 90 km/h, where metre per second and  kilometre per hour are alternative units for the same value of the quantity speed.

Before stating the result of a measurement, it is essential that the quantity being presented is  adequately described. This may be simple, as in the case of the length of a particular steel  rod, but can become more complex when higher accuracy is required and where additional  parameters, such as temperature, need to be specified.

When a measurement result of a quantity is reported, the estimated value of the measurand  (the quantity to be measured), and the uncertainty associated with that value, are necessary.  Both are expressed in the same unit.

2\.2  Definition of the SI

As for any quantity, the value of a fundamental constant can be expressed as the product of  a number and a unit.

The definitions below specify the exact numerical value of each constant when its value is  expressed in the corresponding SI unit. By fixing the exact numerical value, the unit becomes  defined, since the product of the numerical value and the unit has to equal the value of the  constant, which is postulated to be invariant.

The seven constants are chosen in such a way that any unit of the SI can be written either  through a defining constant itself or through products or quotients of defining constants.

The International System of Units, the SI, is the system of units in which

- • the unperturbed ground state hyperfine transition frequency of the caesium  133 atom, ∆νCs, is 9 192 631 770 Hz,
- • the speed of light in vacuum, c, is 299 792 458 m/s,
- • the Planck constant, h, is 6.626 070 15 × 10−34 J s,
- • the elementary charge, e, is 1.602 176 634 × 10−19 C,
- • the Boltzmann constant, k, is 1.380 649 × 10−23 J/K,
- • the Avogadro constant, NA, is 6.022 140 76 × 1023 mol−1,
- • the luminous efficacy of monochromatic radiation of frequency  540 × 1012 Hz, Kcd, is 683 lm/W,

The International System of Units  •  123

where the hertz, joule, coulomb, lumen, and watt, with unit symbols Hz, J, C, lm, and W,  respectively, are related to the units second, metre, kilogram, ampere, kelvin, mole, and  candela, with unit symbols s, m, kg, A, K, mol, and cd, respectively, according to Hz = s–1,  J = kg m2 s– 2, C = A s, lm = cd sr, and W = kg m2 s–3.

The numerical values of the seven defining constants have no uncertainty.

Table 1. The seven defining constants of the SI and the seven corresponding units  they define

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

Defining constant  Symbol Numerical value Unit

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

hyperfine transition

frequency of Cs   ∆νCs 9 192 631 770 Hz

speed of light in vacuum c 299 792 458 m s−1

Planck constant  h 6.626 070 15 × 10−34 J s

elementary charge e 1.602 176 634 × 10−19 C

Boltzmann constant k 1.380 649 × 10−23 J K−1

Avogadro constant NA 6.022 140 76 × 1023 mol−1

luminous efficacy  Kcd 683 lm W−1  \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

Preserving continuity, as far as possible, has always been an essential feature of any changes  to the International System of Units. The numerical values of the defining constants have  been chosen to be consistent with the earlier definitions in so far as advances in science and  knowledge allow.

2\.2.1  The nature of the seven defining constants

The nature of the defining constants ranges from fundamental constants of nature to technical  constants.

The use of a constant to define a unit disconnects definition from realization. This offers the  possibility that completely different or new and superior practical realizations can be  developed, as technologies evolve, without the need to change the definition.

A technical constant such as Kcd, the luminous efficacy of monochromatic radiation of  frequency 540 × 1012 Hz refers to a special application. In principle, it can be chosen freely,  such as to include conventional physiological or other weighting factors. In contrast, the use  of a fundamental constant of nature, in general, does not allow this choice because it is related  to other constants through the equations of physics.

The set of seven defining constants has been chosen to provide a fundamental, stable and  universal reference that simultaneously allows for practical realizations with the smallest  uncertainties. The technical conventions and specifications also take historical developments  into account.

Both the Planck constant h and the speed of light in vacuum c are properly described as  fundamental. They determine quantum effects and space-time properties, respectively, and  affect all particles and fields equally on all scales and in all environments.

The elementary charge e corresponds to a coupling strength of the electromagnetic force via  the fine-structure constant α = e2/(2cε0h) where ε0 is the vacuum electric permittivity or

124  •  The International System of Units

electric constant. Some theories predict a variation of α over time. The experimental limits  of the maximum possible variation in α are so low, however, that any effect on foreseeable  practical measurements can be excluded.

The Boltzmann constant k is a proportionality constant between the quantities temperature  (with the unit kelvin) and energy (with the unit joule), whereby the numerical value is  obtained from historical specifications of the temperature scale. The temperature of a system  scales with the thermal energy, but not necessarily with the internal energy of a system. In  statistical physics the Boltzmann constant connects the entropy S with the number Ω of  quantum-mechanically accessible states, S = k ln Ω.

The caesium frequency ∆νCs, the unperturbed ground-state hyperfine transition frequency of  the caesium 133 atom, has the character of an atomic parameter, which may be affected by  the environment, such as electromagnetic fields. However, the underlying transition is well  understood, stable and a good choice as a reference transition under practical considerations.  The choice of an atomic parameter like ∆νCs does not disconnect definition and realization in  the same way that h, c, e, or k do, but specifies the reference.

The Avogadro constant NA is a proportionality constant between the quantity amount of  substance (with the unit mole) and the quantity number of elementary entities (with the unit  one, symbol 1). Thus it has the character of a constant of proportionality similar to the  Boltzmann constant k.

The luminous efficacy of monochromatic radiation of frequency 540 × 1012 Hz, Kcd, is a  technical constant that gives an exact numerical relationship between the purely physical  characteristics of the radiant power stimulating the human eye (W) and its photobiological  response defined by the luminous flux due to the spectral responsivity of a standard observer  (lm) at a frequency of 540 × 1012 hertz.

2\.3  Definitions of the SI units

Prior to the definitions adopted in 2018, the SI was defined through seven base units from  which the derived units were constructed as products of powers of the base units. Defining  the SI by fixing the numerical values of seven defining constants has the effect that this  distinction is, in principle, not needed, since all units, base as well as derived units, may be  constructed directly from the defining constants. Nevertheless, the concept of base and  derived units is maintained because it is useful and historically well established, noting also  that the ISO/IEC 80000 series of Standards specify base and derived quantities which  necessarily correspond to the SI base and derived units defined here.

The International System of Units  •  125

2\.3.1  Base units

The base units of the SI are listed in Table 2.

Table 2. SI base units

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

Base quantity  Base unit

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

Name  Typical symbol Name  Symbol

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

time  t  second  s

length  l, x, r, etc. metre  m

mass  m  kilogram  kg

electric current I, i  ampere  A

thermodynamic temperature T  kelvin  K

amount of substance n  mole  mol

luminous intensity Iv  candela  cd

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

Starting from the definition of the SI in terms of fixed numerical values of the defining  constants, definitions of each of the seven base units are deduced by using, as appropriate,  one or more of these defining constants to give the following set of definitions:

The second

The second, symbol s, is the SI unit of time. It is defined by taking the fixed numerical  value of the caesium frequency, ∆νCs, the unperturbed ground-state hyperfine  transition frequency of the caesium 133 atom, to be 9 192 631 770 when expressed in the  unit Hz, which is equal to s−1.

This definition implies the exact relation ∆νCs = 9 192 631 770 Hz. Inverting this relation  gives an expression for the unit second in terms of the defining constant ∆νCs:                     1 Hz =   ∆𝑣𝑣Cs 9 192 631 770      or     1 s =   9 192 631 770 ∆𝑣𝑣Cs .

The effect of this definition is that the second is equal to the duration of 9 192 631 770 periods  of the radiation corresponding to the transition between the two hyperfine levels of the  unperturbed ground state of the 133Cs atom.

The reference to an unperturbed atom is intended to make it clear that the definition of the SI  second is based on an isolated caesium atom that is unperturbed by any external field, such  as ambient black-body radiation.

The second, so defined, is the unit of proper time in the sense of the general theory of  relativity. To allow the provision of a coordinated time scale, the signals of different primary  clocks in different locations are combined, which have to be corrected for relativistic caesium  frequency shifts (see section 2.3.6).

The CIPM has adopted various secondary representations of the second, based on a selected  number of spectral lines of atoms, ions or molecules. The unperturbed frequencies of these  lines can be determined with a relative uncertainty not lower than that of the realization of  the second based on the 133Cs hyperfine transition frequency, but some can be reproduced  with superior stability.

126  •  The International System of Units

The metre

The metre, symbol m, is the SI unit of length. It is defined by taking the fixed numerical  value of the speed of light in vacuum, c, to be 299 792 458 when expressed in the unit m  s−1, where the second is defined in terms of the caesium frequency ∆νCs.

This definition implies the exact relation c = 299 792 458 m s−1. Inverting this relation gives  an exact expression for the metre in terms of the defining constants c and ∆νCs:  1 m = � 𝑐𝑐 299 792 458�  s =   9 192 631 770 299 792 458 𝑐𝑐 ∆𝑣𝑣Cs  ≈ 30.663 319  𝑐𝑐 ∆𝑣𝑣Cs  .

The effect of this definition is that one metre is the length of the path travelled by light in  vacuum during a time interval with duration of 1/299 792 458 of a second.

The kilogram

The kilogram, symbol kg, is the SI unit of mass. It is defined by taking the fixed  numerical value of the Planck constant, h, to be 6.626 070 15 × 10−34 when expressed in  the unit J s, which is equal to kg m2 s−1, where the metre and the second are defined in  terms of c and ∆νCs.

This definition implies the exact relation h = 6.626 070 15 × 10−34 kg m2 s−1. Inverting this  relation gives an exact expression for the kilogram in terms of the three defining constants  h, ∆νCs and c:  1 kg =  � ℎ 6.626 070 15 × 10−34 �  m−2 s

which is equal to

1 kg = (299 792 458)2 (6.626 070 15 × 10−34)(9 192 631 770)  ℎ ∆𝑣𝑣Cs 𝑐𝑐2  ≈ 1.475 5214 × 1040  ℎ ∆𝑣𝑣Cs 𝑐𝑐2 .

The effect of this definition is to define the unit kg m2 s−1 (the unit of both the physical  quantities action and angular momentum). Together with the definitions of the second and  the metre this leads to a definition of the unit of mass expressed in terms of the Planck  constant h.

The previous definition of the kilogram fixed the value of the mass of the international  prototype of the kilogram, m(K), to be equal to one kilogram exactly and the value of the  Planck constant h had to be determined by experiment. The present definition fixes the  numerical value of h exactly and the mass of the prototype has now to be determined by  experiment.

The number chosen for the numerical value of the Planck constant in this definition is such  that at the time of its adoption, the kilogram was equal to the mass of the international  prototype, m(K) = 1 kg, with a relative standard uncertainty of 1 × 10−8, which was the  standard uncertainty of the combined best estimates of the value of the Planck constant at  that time.

Note that with the present definition, primary realizations can be established, in principle, at  any point in the mass scale.

The International System of Units  •  127

The ampere

The ampere, symbol A, is the SI unit of electric current. It is defined by taking the fixed  numerical value of the elementary charge, e, to be 1.602 176 634 × 10−19 when expressed  in the unit C, which is equal to A s, where the second is defined in terms of ∆νCs.

This definition implies the exact relation e = 1.602 176 634 × 10−19 A s. Inverting this  relation gives an exact expression for the unit ampere in terms of the defining constants e and  ∆νCs:  1 A = � 𝑒𝑒 1.602 176 634 × 10−19�  s−1

which is equal to

1 A =   1 (9 192 631 770)(1.602 176 634 ×  10−19)  ∆𝑣𝑣Cs 𝑒𝑒 ≈ 6.789 6868 ×  108 ∆𝑣𝑣Cs 𝑒𝑒 .

The effect of this definition is that one ampere is the electric current corresponding to the  flow of 1/(1.602 176 634 × 10−19) elementary charges per second.

The previous definition of the ampere was based on the force between two current carrying  conductors and had the effect of fixing the value of the vacuum magnetic permeability μ0  (also known as the magnetic constant) to be exactly 4π × 10−7 H m−1 = 4π × 10−7 N A−2,  where H and N denote the coherent derived units henry and newton, respectively. The new  definition of the ampere fixes the value of e instead of μ0. As a result, μ0 must be determined  experimentally.

It also follows that since the vacuum electric permittivity ε0 (also known as the electric  constant), the characteristic impedance of vacuum Z0, and the admittance of vacuum Y0 are  equal to 1/μ0c2, μ0c, and 1/μ0c, respectively, the values of ε0, Z0, and Y0 must now also be  determined experimentally, and are affected by the same relative standard uncertainty as μ0  since c is exactly known. The product ε0μ0 = 1/c2 and quotient Z0/μ0 = c remain exact. At the  time of adopting the present definition of the ampere, µ0 was equal to 4π × 10−7 H/m with a  relative standard uncertainty of 2.3 × 10−10.

128  •  The International System of Units

The kelvin

The kelvin, symbol K, is the SI unit of thermodynamic temperature. It is defined by  taking the fixed numerical value of the Boltzmann constant, k, to be 1.380 649 × 10−23  when expressed in the unit J K−1, which is equal to kg m2 s−2 K−1, where the kilogram,  metre and second are defined in terms of h, c and ∆νCs.

This definition implies the exact relation k = 1.380 649 × 10−23 kg m2 s−2 K−1. Inverting this  relation gives an exact expression for the kelvin in terms of the defining constants k, h and  ∆νCs:  1 K =  � 1.380 649 × 10−23 𝑘𝑘 �  kg m2 s−2

which is equal to

1 K =   1.380 649 × 10−23 (6.626 070 15 × 10−34) (9 192 631 770) ∆𝑣𝑣Cs ℎ 𝑘𝑘  ≈ 2.266 6653  ∆𝑣𝑣Cs ℎ 𝑘𝑘  .

The effect of this definition is that one kelvin is equal to the change of thermodynamic  temperature that results in a change of thermal energy kT by 1.380 649 × 10−23 J.

The previous definition of the kelvin set the temperature of the triple point of water, TTPW, to  be exactly 273.16 K. Due to the fact that the present definition of the kelvin fixes the  numerical value of k instead of TTPW, the latter must now be determined experimentally.  At the time of adopting the present definition TTPW was equal to 273.16 K with a relative  standard uncertainty of 3.7 × 10−7 based on measurements of k made prior to the redefinition.

As a result of the way temperature scales used to be defined, it remains common practice to  express a thermodynamic temperature, symbol T, in terms of its difference from the reference  temperature T0 = 273.15 K, close to the ice point. This difference is called the Celsius  temperature, symbol t, which is defined by the quantity equation

t = T − T0 .

The unit of Celsius temperature is the degree Celsius, symbol °C, which is by definition equal  in magnitude to the unit kelvin. A difference or interval of temperature may be expressed in  kelvins or in degrees Celsius, the numerical value of the temperature difference being the  same in either case. However, the numerical value of a Celsius temperature expressed in  degrees Celsius is related to the numerical value of the thermodynamic temperature expressed  in kelvins by the relation

t/°C = T/K − 273.15

(see 5.4.1 for an explanation of the notation used here).

The kelvin and the degree Celsius are also units of the International Temperature Scale of  1990 (ITS-90) adopted by the CIPM in 1989 in Recommendation 5 (CI-1989, PV, 57, 115).  Note that the ITS-90 defines two quantities T90 and t90 which are close approximations to the  corresponding thermodynamic temperatures T and t.

Note that with the present definition, primary realizations of the kelvin can, in principle, be  established at any point of the temperature scale.

The International System of Units  •  129

The mole

The mole, symbol mol, is the SI unit of amount of substance. One mole contains exactly  6.022 140 76 × 1023 elementary entities. This number is the fixed numerical value of the  Avogadro constant, NA, when expressed in the unit mol−1 and is called the Avogadro  number.

The amount of substance, symbol n, of a system is a measure of the number of specified  elementary entities. An elementary entity may be an atom, a molecule, an ion, an  electron, any other particle or specified group of particles.

This definition implies the exact relation NA = 6.022 140 76 × 1023 mol−1. Inverting this  relation gives an exact expression for the mole in terms of the defining constant NA:

1 mol = �  6.022 140 76 × 1023 𝑁𝑁A � .

The effect of this definition is that the mole is the amount of substance of a system that  contains 6.022 140 76 × 1023 specified elementary entities.

The previous definition of the mole fixed the value of the molar mass of carbon 12, M(12C),  to be exactly 0.012 kg/mol. According to the present definition M(12C) is no longer known  exactly and must be determined experimentally. The value chosen for NA is such that at the  time of adopting the present definition of the mole, M(12C) was equal to 0.012 kg/mol with a  relative standard uncertainty of 4.5 × 10−10.

The molar mass of any atom or molecule X may still be obtained from its relative atomic  mass from the equation

M(X) = Ar(X) \[M(12C)/12\] = Ar(X) Mu

and the molar mass of any atom or molecule X is also related to the mass of the elementary  entity m(X) by the relation

M(X) = NA m(X) = NA Ar(X) mu .

In these equations Mu is the molar mass constant, equal to M(12C)/12 and mu is the unified  atomic mass constant, equal to m(12C)/12. They are related to the Avogadro constant through  the relation

Mu = NA mu .

In the name “amount of substance”, the word “substance” will typically be replaced by words  to specify the substance concerned in any particular application, for example “amount of  hydrogen chloride”, or “amount of benzene”. It is important to give a precise definition of  the elementary entity involved (as emphasized in the definition of the mole); this should  preferably be done by specifying the molecular chemical formula of the material involved.  Although the word “amount” has a more general dictionary definition, the abbreviation of  the full name “amount of substance” to “amount” may be used for brevity. This also applies  to derived quantities such as “amount-of-substance concentration”, which may simply be  called “amount concentration”. In the field of clinical chemistry, the name “amount-of- substance concentration” is generally abbreviated to “substance concentration”.

130  •  The International System of Units

The candela

The candela, symbol cd, is the SI unit of luminous intensity in a given direction. It is  defined by taking the fixed numerical value of the luminous efficacy of monochromatic  radiation of frequency 540 × 1012 Hz, Kcd, to be 683 when expressed in the unit lm W−1,  which is equal to cd sr W−1, or cd sr kg−1 m−2 s3, where the kilogram, metre and second  are defined in terms of h, c and ∆νCs.

This definition implies the exact relation Kcd = 683 cd sr kg−1 m−2 s3 for monochromatic  radiation of frequency ν = 540 × 1012 Hz. Inverting this relation gives an exact expression for  the candela in terms of the defining constants Kcd, h and ∆νCs:  1 cd =  � 𝐾𝐾cd 683 �  kg m2 s−3 sr−1

which is equal to  1 cd =   1 (6.626 070 15 × 10−34) (9 192 631 770)2 683  (∆𝑣𝑣Cs)2 ℎ 𝐾𝐾cd  ≈ 2.614 8305 × 1010 (∆𝑣𝑣Cs)2 ℎ 𝐾𝐾cd .

The effect of this definition is that one candela is the luminous intensity, in a given direction,  of a source that emits monochromatic radiation of frequency 540 × 1012 Hz and has a radiant  intensity in that direction of (1/683) W sr−1. The definition of the steradian is given below  Table 4.

2\.3.2  Practical realization of SI units

The highest-level experimental methods used for the realization of units using the equations  of physics are known as primary methods. The essential characteristic of a primary method  is that it allows a quantity to be measured in a particular unit by using only measurements of  quantities that do not involve that unit. In the present formulation of the SI, the basis of the  definitions is different from that used previously, so that new methods may be used for the  practical realization of SI units.

Instead of each definition specifying a particular condition or physical state, which sets a  fundamental limit to the accuracy of realization, a user is now free to choose any convenient  equation of physics that links the defining constants to the quantity intended to be measured.  This is a much more general way of defining the basic units of measurement. It is not limited  by today’s science or technology; future developments may lead to different ways of realizing  units to a higher accuracy. When defined this way, there is, in principle, no limit to the  accuracy with which a unit might be realized. The exception remains the definition of the  second, in which the original microwave transition of caesium must remain, for the time  being, the basis of the definition. For a more comprehensive explanation of the realization of  SI units see Appendix 2.

The International System of Units  •  131

2\.3.3  Dimensions of quantities

Physical quantities can be organized in a system of dimensions, where the system used is  decided by convention. Each of the seven base quantities used in the SI is regarded as having  its own dimension. The symbols used for the base quantities and the symbols used to denote  their dimension are shown in Table 3.

Table 3. Base quantities and dimensions used in the SI

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

Base quantity Typical symbol for quantity Symbol for dimension

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

time t  T

length l, x, r, etc. L

mass m  M

electric current I, i  I

thermodynamic temperature T  Θ

amount of substance n  N

luminous intensity Iv  J

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

All other quantities, with the exception of quantities that are a number of entities, are derived  quantities, which may be written in terms of base quantities according to the equations of  physics. The dimensions of the derived quantities are written as products of powers of the  dimensions of the base quantities using the equations that relate the derived quantities to the  base quantities. In general the dimension of any quantity Q is written in the form of a  dimensional product,

dim Q = Tα LβM γ Iδ Θε Nζ Jη

where the exponents α, β, γ, δ, ε, ζ and η, which are generally small integers, which can be  positive, negative, or zero, are called the dimensional exponents.

There are quantities Q for which the defining equation is such that all of the dimensional  exponents in the equation for the dimension of Q are zero. This is true in particular for any  quantity that is defined as the ratio of two quantities of the same kind. For example, the refractive  index is the ratio of two speeds and the relative permittivity is the ratio of the permittivity of a  dielectric medium to that of free space. Such quantities are simply numbers. The associated unit  is the unit one, symbol 1, although this is rarely explicitly written (see 5.4.7).

There are also some quantities that cannot be described in terms of the seven base quantities  of the SI, but are quantities that are a number of entities. Examples are a number of cellular  or biomolecular entities, or degeneracy in quantum mechanics. These quantities are also  quantities with the unit one.

The unit one is the neutral element of any system of units – necessary and present automatically.  There is no requirement to introduce it formally by decision. Formal traceability to the SI can  be established through appropriate, validated measurement procedures.

For reasons of history and convention, plane and solid angles are treated within the SI as  quantities with the unit one (see section 2.3.4). The symbols rad and sr are written explicitly  where appropriate, in order to emphasize that, for radians or steradians, the quantity being  considered is, or involves the plane angle or solid angle respectively. For steradians it

132  •  The International System of Units

emphasizes the distinction between units of flux and intensity in radiometry and photometry  for example. It is noted that in mathematics and some areas of science rad and sr are omitted.

It is especially important to have a clear description of any quantity with the unit one (see section  5.4.7) that is expressed as a ratio of quantities of the same kind (for example length ratios or  amount fractions) or as a number of entities (for example number of photons or decays).

2\.3.4  Derived units

Derived units are defined as products of powers of the base units. When the numerical factor  of this product is one, the derived units are called coherent derived units. The base and  coherent derived units of the SI form a coherent set, designated the set of coherent SI units.  The word “coherent” here means that equations between the numerical values of quantities  take exactly the same form as the equations between the quantities themselves.

Some of the coherent derived units in the SI are given special names. Table 4 lists 22 SI units  with special names. Together with the seven base units (Table 2) they form the core of the  set of SI units. All other SI units are combinations of some of these 29 units.

It is important to note that any of the seven base units and 22 SI units with special names can  be constructed directly from the seven defining constants. In fact, the units of the seven  defining constants include both base and derived units.

The CGPM has adopted a series of prefixes for use in forming the decimal multiples and sub- multiples of the coherent SI units (see chapter 3). They are convenient for expressing the  values of quantities that are much larger than or much smaller than the coherent unit.  However, when prefixes are used with SI units, the resulting units are no longer coherent,  because the prefix introduces a numerical factor other than one. Prefixes may be used with  any of the 29 SI units with special names with the exception of the base unit kilogram, which  is further explained in chapter 3.

Table 4. The 22 SI units with special names and symbols

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

Special name   Unit expressed in  Unit expressed in

Derived quantity  of unit  Symbol terms of base units (a)   terms of other SI units

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

plane angle  radian (b) rad  (b)    1

solid angle steradian (c) sr  (c)     1

frequency hertz (d)  Hz  s−1

force  newton  N  kg m s−2

pressure, stress pascal  Pa  kg m−1 s−2   N/m2

energy, work,  joule  J  kg m2 s−2   N m

amount of heat

power, radiant flux watt  W  kg m2 s−3   J/s

electric charge coulomb C  A s

electric potential difference (e) volt  V  kg m2 s−3 A−1   W/A

capacitance farad  F  kg−1 m−2 s4 A2   C/V

electric resistance ohm Ω  kg m2 s−3 A−2   V/A

electric conductance siemens  S  kg−1 m−2 s3 A2   A/V

magnetic flux weber  Wb  kg m2 s−2 A−1   V s

magnetic flux density tesla  T  kg s−2 A−1   Wb/m2

inductance henry  H  kg m2 s−2 A−2   Wb/A

The International System of Units  •  133

Celsius temperature degree Celsius (f) °C  K

luminous flux lumen  lm  cd sr (g)   cd sr

illuminance lux  lx  cd sr m−2    lm/m2

activity referred to becquerel Bq  s−1

a radionuclide (d, h)

absorbed dose, kerma gray  Gy  m2 s−2   J/kg

dose equivalent sievert (i) Sv  m2 s−2   J/kg

catalytic activity katal  kat  mol s−1

(a) The order of symbols for base units in this Table is different from that in the 8th edition following a  decision by the CCU at its 21st meeting (2013) to return to the original order in Resolution 12 of the  11th CGPM (1960) in which newton was written kg m s−2, the joule as kg m2 s−2 and J s as kg m2 s−1.  The intention was to reflect the underlying physics of the corresponding quantity equations although  for some more complex derived units this may not be possible.

(b) The radian is the coherent unit for plane angle. One radian is the [angle](https://en.wikipedia.org/wiki/Angle) [subtended](https://en.wikipedia.org/wiki/Subtended) at the centre of a  [circle](https://en.wikipedia.org/wiki/Circle) by an [arc](https://en.wikipedia.org/wiki/Arc_%28geometry%29) that is equal in length to the [radius](https://en.wikipedia.org/wiki/Radius). This suggests rad = m/m but this representation is  not intrinsic and may be misleading since angle is not the same kind of quantity as other length ratios.  An alternative definition is that a right angle is equal to π/2 rad. The radian is also the coherent unit  for phase angle. For periodic phenomena, the phase angle increases by 2π rad in one period.

(c) The steradian is the coherent unit for solid angle. One steradian is the solid angle subtended at the centre  of a sphere by an area of the surface that is equal to the squared radius. This suggests sr = m2/m2, but this  representation is not intrinsic and may be misleading since solid angle is not the same kind of quantity as  other area ratios. An alternative definition is that a complete sphere subtends 4π sr about its centre.

(d) The hertz shall only be used for periodic phenomena and the becquerel shall only be used for stochastic  processes in activity referred to a radionuclide.

(e) Electric potential difference is also called “voltage” in many countries, as well as “electric tension” or  simply “tension” in some countries.

(f) The degree Celsius is used to express Celsius temperatures. The numerical value of a temperature  difference or temperature interval is the same when expressed in either degrees Celsius or in kelvins.

(g) In photometry the name steradian and the symbol sr are usually retained in expressions for units.

(h) Activity referred to a radionuclide is sometimes incorrectly called radioactivity.

(i) See CIPM Recommendation 2 on the use of the sievert (PV, 2002, 70, 205).

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

The seven base units and 22 units with special names and symbols may be used in  combination to express the units of other derived quantities. Since the number of quantities  is without limit, it is not possible to provide a complete list of derived quantities and derived  units. Table 5 lists some examples of derived quantities and the corresponding coherent  derived units expressed in terms of base units. In addition, Table 6 lists examples of coherent  derived units whose names and symbols also include derived units. The complete set of SI  units includes both the coherent set and the multiples and sub-multiples formed by using the  SI prefixes.

134  •  The International System of Units

[https://en.wikipedia.org/wiki/Angle](https://en.wikipedia.org/wiki/Angle)

[https://en.wikipedia.org/wiki/Subtended](https://en.wikipedia.org/wiki/Subtended)

[https://en.wikipedia.org/wiki/Circle](https://en.wikipedia.org/wiki/Circle)

[https://en.wikipedia.org/wiki/Arc\_%28geometry%29](https://en.wikipedia.org/wiki/Arc_%28geometry%29)

[https://en.wikipedia.org/wiki/Radius](https://en.wikipedia.org/wiki/Radius)

Table 5. Examples of coherent derived units in the SI expressed in terms of base  units

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

Derived quantity Typical symbol  Derived unit expressed

of quantity in terms of base units

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

area A  m2

volume V  m3

speed, velocity v  m s−1

acceleration a  m s−2

wavenumber σ  m−1

density, mass density ρ  kg m−3

surface density ρA  kg m−2

specific volume v  m3 kg−1

current density j  A m−2

magnetic field strength H  A m−1

amount-of-substance concentration c  mol m−3

mass concentration ρ, γ  kg m−3

luminance Lv  cd m−2

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

Table 6. Examples of SI coherent derived units whose names and symbols include  SI coherent derived units with special names and symbols

Derived unit expressed

Derived quantity Name of coherent derived unit Symbol  in terms of base units

dynamic viscosity pascal second Pa s  kg m−1 s−1

moment of force, torque  newton metre N m  kg m2 s−2

surface tension  newton per metre N m−1  kg s−2

angular velocity,  radian per second rad s−1

angular frequency

angular acceleration  radian per second squared rad s−2

heat flux density, watt per square metre  W m−2  kg s−3

irradiance

heat capacity, entropy  joule per kelvin J K−1  kg m2 s−2 K−1

specific heat capacity, joule per kilogram kelvin J kg−1 K−1 m2 s−2 K−1

specific entropy

specific energy  joule per kilogram J kg−1  m2 s−2

thermal conductivity watt per metre kelvin W m−1 K−1 kg m s−3 K−1

energy density joule per cubic metre J m−3  kg m−1 s−2

electric field strength  volt per metre V m−1  kg m s−3 A−1

electric charge density  coulomb per cubic metre C m−3  A s m−3

surface charge density coulomb per square metre C m−2  A s m−2

electric flux density, coulomb per square metre C m−2  A s m−2

electric displacement

permittivity farad per metre F m−1  kg−1 m−3 s4 A2

permeability henry per metre H m−1  kg m s−2 A−2

molar energy  joule per mole J mol−1  kg m2 s−2 mol−1

The International System of Units  •  135

molar entropy, joule per mole kelvin  J mol−1 K−1  kg m2 s−2 mol−1 K−1

molar heat capacity

exposure (x- and γ-rays)  coulomb per kilogram  C kg−1  A s kg−1

absorbed dose rate gray per second Gy s−1  m2 s−3

radiant intensity  watt per steradian W sr−1  kg m2 s−3 sr−1 (a)

radiance  watt per square metre steradian W m−2 sr−1  kg s−3 sr−1

catalytic activity  katal per cubic metre kat m−3  mol s−1 m−3   concentration

(a) In radiometry the name steradian and the symbol sr are usually retained in expressions for units.

It is important to emphasize that each physical quantity has only one coherent SI unit, even though  this unit can be expressed in different forms by using some of the special names and symbols.

The converse, however, is not true, because in general several different quantities may share  the same SI unit. For example, for the quantity heat capacity as well as for the quantity  entropy the SI unit is joule per kelvin. Similarly, for the base quantity electric current as well  as the derived quantity magnetomotive force the SI unit is the ampere. It is therefore  important not to use the unit alone to specify the quantity. This applies not only to technical  texts, but also, for example, to measuring instruments (i.e. the instrument read-out needs to  indicate both the unit and the quantity measured).

In practice, with certain quantities, preference is given to the use of certain special unit names  to facilitate the distinction between different quantities having the same dimension. When  using this freedom, one may recall the process by which this quantity is defined. For example,  the quantity torque is the cross product of a position vector and a force vector. The SI unit is  newton metre. Even though torque has the same dimension as energy (SI unit joule), the joule  is never used for expressing torque.

The SI unit of frequency is hertz, the SI unit of angular velocity and angular frequency is  radian per second. The SI unit of activity is becquerel, implying counts per second. The use  of the different names emphasizes the different nature of the quantities concerned. It is  especially important to carefully distinguish frequencies from angular frequencies, because  by definition their numerical values differ by a factor of 2π (see ISO 80000-3 for details).  Ignoring this fact may cause an error of 2π. Note that in some countries, frequency values are  conventionally expressed using “cycle/s” (“cps”) or “revolution/s” (“rev/s”) instead of the SI  unit Hz, although “cycle”, “cps”, “revolution” and “rev” are not units in the SI. Note also that  it is common, although not recommended, to use the term frequency for quantities expressed  in rad/s. Because of this, it is recommended that quantities called “frequency”, “angular  frequency”, and “angular velocity” always be given explicit units of Hz or rad/s and not s−1.

In the field of ionizing radiation, the SI unit becquerel rather than the reciprocal second is  used. The SI units gray and sievert are used for absorbed dose and dose equivalent,  respectively, rather than joule per kilogram. The special names becquerel, gray and sievert  were specifically introduced because of the dangers to human health that might arise from  mistakes involving the units reciprocal second and joule per kilogram, in case the latter units  were incorrectly taken to identify the different quantities involved.

Special care must be taken when expressing temperatures or temperature differences,  respectively. A temperature difference of 1 K equals that of 1 °C, but for an absolute  temperature the difference of 273.15 K must be taken into account. The unit degree Celsius  is only coherent when expressing temperature differences.

136  •  The International System of Units

2\.3.5  Units for quantities that describe biological and physiological  effects

Four of the SI units listed in tables 2 and 4 include physiological weighting factors: candela,  lumen, lux and sievert.

Lumen and lux are derived from the base unit candela. Like the candela, they carry information  about human vision. The candela was established as a base unit in 1954, acknowledging the  importance of light in daily life. Further information on the units and conventions used for  defining photochemical and photobiological quantities is in Appendix 3.

Ionizing radiation deposits energy in irradiated matter. The ratio of deposited energy to mass  is termed absorbed dose D. As decided by the CIPM in 2002, the quantity dose equivalent  H = Q D is the product of the absorbed dose D and a numerical quality factor Q that takes  into account the biological effectiveness of the radiation and is dependent on the energy and  type of radiation.

There are units for quantities that describe biological effects and involve weighting factors,  which are not SI units. Two examples are given here:

Sound causes pressure fluctuations in the air, superimposed on the normal atmospheric  pressure, that are sensed by the human ear. The sensitivity of the ear depends on the frequency  of the sound, but it is not a simple function of either the pressure changes or the frequency.  Therefore, frequency-weighted quantities are used in acoustics to approximate the way in  which sound is perceived. They are used, for example, for measurements concerning  protection against hearing damage. The effect of ultrasonic acoustic waves poses similar  concerns in medical diagnosis and therapy.

There is a class of units for quantifying the biological activity of certain substances used in  medical diagnosis and therapy that cannot yet be defined in terms of the units of the SI. This  lack of definition is because the mechanism of the specific biological effect of these  substances is not yet sufficiently well understood for it to be quantifiable in terms of physico- chemical parameters. In view of their importance for human health and safety, the World  Health Organization (WHO) has taken responsibility for defining WHO International Units  (IU) for the biological activity of such substances.

2\.3.6  SI units in the framework of the general theory of relativity

The practical realization of a unit and the process of comparison require a set of equations  within a framework of a theoretical description. In some cases, these equations include  relativistic effects.

For frequency standards it is possible to establish comparisons at a distance by means of  electromagnetic signals. To interpret the results, the general theory of relativity is required,  since it predicts, among other things, a relative frequency shift between standards of about  1 part in 1016 per metre of altitude difference at the surface of the earth. Effects of this  magnitude must be corrected for when comparing the best frequency standards.

When practical realizations are compared locally, i.e. in a small space-time domain, effects  due to the space-time curvature described by the general theory of relativity can be neglected.  When realizations share the same space-time coordinates (for example the same motion and  acceleration or gravitational field), relativistic effects may be neglected entirely.

The International System of Units  •  137

- 3 Decimal multiples and sub-multiples of SI units

Decimal multiples and submultiples ranging from 1030 to 10−30 are provided for use with the  SI units. The names and symbols of these multiple and sub-multiple prefixes are presented  in Table 7.

Prefix symbols are printed in upright typeface, as are unit symbols, regardless of the typeface  used in the surrounding text and are attached to unit symbols without a space between the  prefix symbol and the unit symbol. With the exception of da (deca), h (hecto) and k (kilo),  all multiple prefix symbols are upper-case letters and all sub-multiple prefix symbols are  lower-case letters. All prefix names are printed in lower-case letters, except at the beginning  of a sentence.

Table 7. SI prefixes

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

Factor Name Symbol Factor Name Symbol

101 deca da 10−1 deci d

102 hecto h 10−2 centi c

103 kilo k 10−3 milli m

106 mega M 10−6 micro µ

109 giga G 10−9 nano n

1012 tera T 10−12 pico p

1015 peta P 10−15 femto f

1018 exa E 10−18 atto a

1021 zetta Z 10−21 zepto z

1024 yotta Y 10−24 yocto y

1027 ronna R 10−27 ronto r

1030 quetta Q 10−30 quecto q

\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

The grouping formed by a prefix symbol attached to a unit symbol constitutes a new  inseparable unit symbol (forming a multiple or sub-multiple of the unit concerned) that can  be raised to a positive or negative power and that can be combined with other unit symbols  to form compound unit symbols.

Examples: pm (picometre), mmol (millimole), GΩ (gigaohm), THz (terahertz)

2\.3 cm3 = 2.3 (cm)3 = 2.3 (10−2 m)3 = 2.3 ×10−6 m3

1 cm−1 = 1 (cm)−1 = 1 (10−2 m)−1 = 102 m−1 = 100 m−1 .

Similarly prefix names are also inseparable from the unit names to which they are attached.  Thus, for example, millimetre, micropascal and meganewton are single words.

Compound prefix symbols, i.e. prefix symbols formed by the juxtaposition of two or more  prefix symbols, are not permitted. This rule also applies to two or more compound prefix  names.

Prefix symbols can neither stand alone nor be attached to the number 1, the symbol for the  unit one. Similarly, prefix names cannot be attached to the name of the unit one, that is, to  the word “one”.

138  •  Decimal multiples and sub-multiples

For historical reasons, the kilogram is the only coherent SI unit that includes a prefix in its  name and symbol. Names and symbols for decimal multiples and sub-multiples of the unit of  mass are formed by attaching prefix names and symbols to the unit name “gram” and the unit  symbol “g” respectively. For example, 10−6 kg is written as milligram, mg, not as  microkilogram, µkg.

The SI prefixes refer strictly to powers of 10. They should not be used to indicate powers of  2 (for example, one kilobit represents 1000 bits and not 1024 bits). The names and symbols  for prefixes corresponding to powers of 2 are the following: kibi (Ki) for 210, mebi (Mi) for  220, gibi (Gi) for 230, tebi (Ti) for 240, pebi (Pi) for 250, exbi (Ei) for 260, zebi (Zi) for 270, yobi  (Yi) for 280, robi (Ri) for 290, and quebi (Qi) for 2100 (see IEC 80000-13 for details).

Decimal multiples and sub-multiples  •  139

- 4 Non-SI units

It is recognized that some non-SI units are widely used and that this is expected to continue  for many years. It is therefore important to recall the values of these non-SI units in terms of  SI units, because the SI is the internationally agreed reference with respect to which all other  units are defined. A non-exhaustive list of non-SI units is given in Table 8, grouped into  indicative unit categories to aid explanation.

Table 8. Non-SI units

||
|---|
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||
||

Unit category

Quantity

Name of unit

Symbol  for unit

Value in SI units

Long-standing  units of time and  angle

time

minute

min

1 min = 60 s

hour

h

1 h = 60 min = 3600 s

day

d

1 d = 24 h = 86 400 s

plane and  phase angle

degree

°

1° = (π/180) rad

minute

′

1′ = (1/60)° = (π/10 800) rad

second (a)

″

1″ = (1/60)′ = (π/648 000) rad

Historical names  for decimal  multiples and  submultiples  of SI units

area

are (b)

a

1 a = 1 dam2 = 102 m2

hectare (b)

ha

1 ha = 1 hm2 = 104 m2

barn (c)

b

1 b = 100 fm2 = 10−28 m2

volume

litre (d)

l, L

1 l = 1 L = 1 dm3 = 10−3 m3

mass

tonne (e)

t

1 t = 1 Mg = 103 kg

length

angstrom (f)

Å

1 Å = 0.1 nm = 10−10 m

acceleration

gal (g)

Gal

1 Gal = 1 cm/s2 = 10−2 m/s2

pressure

bar (h)

bar

1 bar = 0.1 MPa = 105 Pa

Internationally  recognised units  that are not  decimal multiples  or submultiples  of SI units

mass

dalton (i)

Da

1 Da =  1.660 539 068 92(52) × 10−27 kg

length

astronomical unit (j)

au

1 au = 149 597 870 700 m

nautical mile (k)

1 nautical mile = 1852 m

speed

knot (k)

1 nautical mile per hour =  (1852/3600) m/s

energy

electronvolt (l)

eV

1 eV = 1.602 176 634 × 10−19 J

Units used in  specialized  technical  disciplines

logarithmic  ratio quantities

neper (m)

Np

(m)

bel (m)

B

(m)

decibel (m)

dB

(m)

reactive power

var (n)

var

1 var = 1 V A = 1 W

140  •  Non-SI units

(a) For some applications such as in astronomy, small angles are measured in arcseconds (with unit  symbols: as or ″) or milliarcseconds, microarcseconds and picoarcseconds (with unit symbols: mas,  μas and pas, respectively) where arcsecond is an alternative name for second of plane angle.

(b)  The CIPM adopted the units are and hectare, and their symbols, in 1879. They are used to express land  area.

(c)  The barn is used in nuclear physics to express effective cross sections.

(d)  The litre and the symbol, lower-case l, were adopted by the CIPM in 1879. The alternative symbol,  capital L, was adopted by Resolution 6 of the 16th CGPM in 1979 in order to avoid the risk of confusion  between the letter l (el) and the numeral 1 (one).

(e)  The tonne and its symbol, t, were adopted by the CIPM in 1879. This unit is sometimes referred to as  “metric ton” in some English-speaking countries.

(f)  The angstrom is used to express lengths of chemical bonds, sizes of atoms and molecules, and  wavelengths.

(g)  The gal is used in geodesy and geophysics to express acceleration due to gravity and originates from  the CGS system.

(h)  The bar and its symbol were included in Resolution 7 of the 9th CGPM in 1948.

(i)  The dalton (symbol Da) and the unified atomic mass unit (symbol u) are alternative names (and  symbols) for the same unit, equal to 1/12 of the mass of a free carbon 12 atom, at rest and in its ground  state. This value of the dalton is the value recommended in the 2022 CODATA Recommended Values  of the Fundamental Physical Constants.

(j)  Defined by Resolution B2 of the XXVIII General Assembly of the International Astronomical Union  in 2012.

(k)  The nautical mile and the knot are used in marine and aerial navigation to express distance and speed,  respectively. There is no internationally agreed unit symbol for either unit. The size of the nautical  mile was defined by the 1st Extraordinary International Hydrographic Conference in 1929.

(l)  The electronvolt is the kinetic energy acquired by an electron in passing through a potential difference  of one volt in vacuum. Following adoption of Resolution 1 of the 26th CGPM in 2018, which fixed  the numerical value of the elementary charge, this conversion factor has been exact.

(m)  The neper, bel and decibel are used to express values of specified logarithmic ratio quantities. When  using these units, it is important that the quantity be specified, and that any reference value used be  specified. The neper, Np, is used to express the values of quantities whose numerical values are based  on the use of the neperian (or natural) logarithm, ln = loge, usually applied to logarithmic amplitude  ratios. The statement LA = n Np (where n is a number) is interpreted to mean that n = ln(A2/A1). The  symbol A typically denotes the amplitude of a sinusoidal signal, and LA is then called the neperian  logarithmic amplitude ratio. The bel and the decibel, B and dB, where 1 dB = (1/10) B, are used to  express the values of logarithmic ratio quantities whose numerical values are based on the decadic  logarithm, lg = log10, usually applied to logarithmic power ratios. The statement LX = m dB = (m/10)  B (where m is a number) is interpreted to mean that m = 10 lg(X/X0). If X denotes a mean square signal  or power-like quantity, LX is called a power level referred to X0.

(n)  The var is a special name for the unit of reactive power. It is identical to the coherent SI unit volt  ampere.

Non-SI units  •  141

# 5  Writing unit symbols and names, and expressing  the values of quantities

## 5.1 The use of unit symbols and names

General principles for the writing of unit symbols and numbers were first given by the  9th CGPM (1948, Resolution 7). These were subsequently elaborated by ISO, IEC and other  international bodies. As a consequence, there now exists a general consensus on how unit  symbols and names, including prefix symbols and names as well as quantity symbols should  be written and used, and how the values of quantities should be expressed. Compliance with  these rules and style conventions, the most important of which are presented in this chapter,  supports the readability and unambiguity of numerical results expressed in SI units.

## 5.2 Unit symbols

Unit symbols are mandatory. They are printed in upright type regardless of the type used in  the surrounding text. They are printed in lower-case letters unless they are derived from a  proper name, in which case the first letter is a capital letter.

An exception, adopted by the 16th CGPM (1979, Resolution 6), is that either capital L or  lower-case l is allowed for the litre, in order to avoid possible confusion between the numeral  1 (one) and the lower-case letter l (el).

A multiple or sub-multiple prefix, if used, is part of the unit and precedes the unit symbol  without a separator. A prefix is never used in isolation and compound prefixes are never used.

Unit symbols are mathematical entities and not abbreviations. Therefore, they are not  followed by a full stop except at the end of a sentence, and one must neither use the plural  nor mix unit symbols and unit names within one expression, since names are not  mathematical entities.

In forming products and quotients of unit symbols the normal rules of algebraic multiplication  or division apply. Multiplication must be indicated by a space or a half-high (centred) dot (⋅),  since otherwise some prefixes could be misinterpreted as a unit symbol. Division is indicated  by a horizontal line, by a solidus (oblique stroke, /) or by negative exponents. For example,  m/s = m s−1 and mol/mol = mol mol−1. When several unit symbols are combined, care should  be taken to avoid ambiguities, for example by using parentheses or negative exponents. A  solidus must not be used more than once in a given expression without parentheses to remove  ambiguities.

It is not permissible to use abbreviations for unit symbols or unit names, such as sec (for  either s or second), sq. mm (for either mm2 or square millimetre), cc (for either cm3 or cubic  centimetre), or mps (for either m/s or metre per second). The use of the correct symbols for  SI units, and for units in general, as listed in earlier chapters of this brochure, is mandatory.  In this way ambiguities and misunderstandings in the values of quantities are avoided.

142  •  Writing unit symbols and names

## 5.3 Unit names

Unit names are normally printed in upright type and they are treated like ordinary nouns. In  English, the names of units start with a lower-case letter (even when the symbol for the unit  begins with a capital letter), except at the beginning of a sentence or in capitalized material  such as a title. In keeping with this rule, the correct spelling of the name of the unit with the  symbol °C is “degree Celsius” (the unit degree begins with a lower-case d and the modifier  Celsius begins with an upper-case C because it is a proper name).

Although the values of quantities are normally expressed using symbols for numbers and  symbols for units, if for some reason the unit name is more appropriate than the unit symbol,  the unit name should be spelled out in full.

When the name of a unit is combined with the name of a multiple or sub-multiple prefix,  no space or hyphen is used between the prefix name and the unit name. The combination of  prefix name and unit name is a single word (see chapter 3).

When the name of a derived unit is formed from the names of individual units by juxtaposition,  either a space or a hyphen is used to separate the names of the individual units.

## 5.4 Rules and style conventions for expressing values of quantities

### 5.4.1 Value and numerical value of a quantity, and the use of quantity calculus

The symbols for quantities are recommendations. They are generally single letters of the  Latin or Greek alphabets printed in an italic font, although they may be qualified by further  information in subscripts or superscripts or in parentheses. For example, C is the  recommended symbol for heat capacity, cm for molar heat capacity, cm,p for molar heat  capacity at constant pressure, and cm,V for molar heat capacity at constant volume.

Recommended names and symbols for quantities are listed in many standard references, such as  the ISO/IEC 80000 series Quantities and units, the IUPAP SUNAMCO Red Book Symbols, Units  and Nomenclature in Physics and the IUPAC Green Book Quantities, Units and Symbols in  Physical Chemistry. However, symbols for quantities are recommendations (in contrast to  symbols for units, for which the use of the correct form is mandatory). In certain circumstances  authors may wish to use a symbol of their own choice for a quantity, for example to avoid a  conflict arising from the use of the same symbol for two different quantities. In such cases, the  meaning of the symbol must be clearly stated. However, neither the name of a quantity, nor the  symbol used to denote it, should imply any particular choice of unit.

Symbols for units are treated as mathematical entities. In expressing the value of a quantity as  the product of a numerical value and a unit, both the numerical value and the unit may be treated  by the ordinary rules of algebra. This procedure is described as the use of quantity calculus, or  the algebra of quantities. For example, the equation p = 48 kPa may equally be written as  p/kPa = 48. It is common practice to write the quotient of a quantity and a unit in this way for  a column heading in a table, so that the entries in the table are simply numbers. For example, a  table of the velocity squared versus pressure may be formatted as shown below.

||
|---|
||
||
||

p/kPa

v2/(m/s)2

48\.73

94 766

72\.87

94 771

135\.42

94 784

Writing unit symbols and names  •  143

94 750

94 760

94 770

94 780

94 790

0

50

100

150

p/kPa

v 2 /( m /s )2

The axes of a graph may also be labelled in this way, so that the tick marks are labelled only  with numbers, as in the graph below.

### 5.4.2 Quantity symbols and unit symbols

Unit symbols must not be used to provide specific information about the quantity and should  never be the sole source of information on the quantity. Units are never qualified by further  information about the nature of the quantity; any extra information on the nature of the  quantity should be attached to the quantity symbol and not to the unit symbol. For example,  the maximum electric potential difference is Umax = 1000 V but not U = 1000 Vmax. The mass  fraction of copper in the sample of silicon is w(Cu) = 1.3 × 10−6 but not 1.3 × 10−6 w/w.

### 5.4.3 Formatting the value of a quantity

The numerical value always precedes the unit and a space is always used to separate the unit  from the number. Thus the value of the quantity is the product of the number and the unit.  The space between the number and the unit is regarded as a multiplication sign (just as a  space between units implies multiplication). The only exceptions to this rule are for the unit  symbols for degree, minute and second for plane angle, °, ′ and ″, respectively, for which no  space is left between the numerical value and the unit symbol. For example, m = 12.3 g  where m is used as a symbol for the quantity mass, but φ = 30° 22′ 8″, where φ is used as a  symbol for the quantity plane angle.

This rule means that the symbol °C for the degree Celsius is preceded by a space when one  expresses values of Celsius temperature t. For example, t = 30.2 °C but not t = 30.2°C nor  t = 30.2° C.

Even when the value of a quantity is used as an adjective, a space is left between the  numerical value and the unit symbol. Only when the name of the unit is spelled out would  the ordinary rules of grammar apply, so that in English a hyphen would be used to separate  the number from the unit. For example, a 10 kΩ resistor; a 35-millimetre film.

144  •  Writing unit symbols and names

In any expression, only one unit is used. For example, l = 10.234 m but not l = 10 m 23.4 cm.  An exception to this rule is in expressing the values of time and of plane angles using non-SI  units. However, for plane angles it is generally preferable to divide the degree decimally. It  is therefore preferable to write 22.20° rather than 22° 12′, except in fields such as navigation,  cartography, astronomy, and in the measurement of very small angles.

### 5.4.4 Formatting numbers, and the decimal marker

The symbol used to separate the integral part of a number from its decimal part is called the  decimal marker. Following a decision by the 22nd CGPM (2003, Resolution 10), the decimal  marker “shall be either the point on the line or the comma on the line.” The decimal marker  chosen should be that which is customary in the language and context concerned.

If the number is between +1 and −1, then the decimal marker is always preceded by a zero.  For example −0.234 but not −.234.

Following the 9th CGPM (1948, Resolution 7) and the 22nd CGPM (2003, Resolution 10),  for numbers with many digits the digits may be divided into groups of three by a space, in  order to facilitate reading. Neither dots nor commas are ever inserted in the spaces between  groups. For example, 43 279.168 29 but not 43,279.168,29. However, when there are only  four digits before or after the decimal marker, it is customary not to use a space to isolate a  single digit. The practice of grouping digits in this way is a matter of choice; it is not always  followed in certain specialized applications such as engineering drawings, financial  statements and scripts to be read by a computer. For example, either 3279.1683 or  3 279.168 3.

For numbers in a table, the format used should not vary within one column.

### 5.4.5 Expressing the measurement uncertainty in the value of a quantity

The uncertainty associated with an estimated value of a quantity should be evaluated and  expressed in accordance with the document JCGM 100:2008 (GUM 1995 with minor  corrections), Evaluation of measurement data - Guide to the expression of uncertainty in  measurement. The standard uncertainty associated with a quantity x is denoted by u(x). One  convenient way to represent the standard uncertainty is given in the following example:

mn = 1.674 927 471 (21) × 10−27 kg,

where mn is the symbol for the quantity (in this case the mass of a neutron) and the number  in parentheses is the numerical value of the standard uncertainty of the estimated value of mn  referred to the last digits of the quoted value; in this case u(mn) = 0.000 000 021 × 10−27 kg.  If an expanded uncertainty U(x) is used in place of the standard uncertainty u(x), then the  coverage probability p and the coverage factor k must be stated.

Writing unit symbols and names  •  145

### 5.4.6 Multiplying or dividing quantity symbols, the values of quantities,  or numbers

When multiplying or dividing quantity symbols any of the following methods may be used:

ab, a b, a⋅ b, a × b, a/b, 𝑎𝑎 𝑏𝑏 , a b−1.

For example, F = ma for force equals mass times acceleration. When multiplying the value  of quantities either a multiplication sign × or parentheses should be used, not a half-high  (centred) dot. For example, (53 m/s) × 10.2 s, or (53 m/s)(10.2 s), but not 53 m/s ⋅ 10.2 s.  When multiplying numbers only the multiplication sign × should be used. For example,  25 × 60.5 but not 25 ⋅ 60.5.

When dividing the values of quantities using a solidus, parentheses are used to avoid  ambiguity. For example, (20 m)/(5 s) = 4 m/s, and (a/b)/c, but not a/b/c.

### 5.4.7 Quantities with the unit one

As discussed in Section 2.3.3, values of quantities with the unit one can be expressed simply  as numbers. The unit symbol 1 or unit name “one” are rarely explicitly written. For example,  n = 1.51, but not n = 1.51 × 1, where n is the quantity symbol for refractive index. SI prefix  symbols can neither be attached to the symbol 1 nor to the name “one”, therefore powers of  10 are used to express particularly large or small values.

Quantities that are ratios of quantities of the same kind (for example length ratios and amount  fractions) have the option of being expressed with units (m/m, mol/mol) to aid the  understanding of the quantity being expressed and also allow the use of SI prefixes, if this is  desirable (µm/m, nmol/mol). Quantities that are a number of entities do not have this option.

Whilst not part of the SI, descriptive terms are commonly used in place of the unit one to  indicate the entities being considered when expressing the values of quantities that are a  number of entities. If this is done, the definitions of such terms and the conventions for their  use must be clearly documented. The general principles of Section 5 should also be followed.

The internationally recognized symbol % (per cent) may be used with the SI. When it is used,  a space separates the number and the symbol %. The symbol % should be used rather than  the name “per cent”. In written text, however, the symbol % generally takes the meaning of  “parts per hundred”. Phrases such as “percentage by mass”, “percentage by volume”, or  “percentage by amount of substance” shall not be used; the extra information on the quantity  should instead be conveyed in the description and symbol for the quantity.

The term “parts per million” or “ppm”, meaning 10−6 relative value, or parts in 106, is also  used. This is analogous to the meaning of per cent as parts per hundred. The terms “parts per  billion” and “parts per trillion” and their respective abbreviations “ppb” and “ppt” are also  used, but their meanings are language dependent. For this reason the abbreviations ppb and  ppt should be avoided.

146  •  Writing unit symbols and names

# Appendix 1. Decisions of the CGPM and the CIPM

This appendix lists those decisions of the CGPM and the CIPM that bear directly upon  definitions of the units of the SI, prefixes defined for use as part of the SI, and conventions  for the writing of unit symbols and numbers. It is not a complete list of CGPM and CIPM  decisions. For a complete list, reference must be made to successive volumes of the  Comptes Rendus des Séances de la Conférence Générale des Poids et Mesures (CR) and  Procès-Verbaux des Séances du Comité International des Poids et Mesures (PV) or,  for recent decisions, to Metrologia.

Since the SI is not a static convention, but evolves following developments in the science of  measurement, some decisions have been abrogated or modified; others have been clarified  by additions. Notes have been added to decisions that have been subject to such changes.  These, and other informative notes, are shown in italic font and do not form part of the  original text.

The decisions of the CGPM and CIPM are listed in this appendix in strict chronological  order, from 1889 to 2022, in order to preserve the continuity with which they were taken.  However in order to make it easy to locate decisions related to particular topics a table of  contents is included below, ordered by subject, with page references to the particular  meetings at which decisions relating to each subject were taken.

Appendix 1  •  147

# Table of Contents of Appendix 1

Decisions relating to the establishment of the SI   page

9th CGPM, 1948: decision to establish the SI 156

10th CGPM, 1954: decision on the first six base units 158

CIPM 1956:  decision to adopt the name “Système International d’Unités” 158

11th CGPM, 1960: confirms the name and the abbreviation “SI”, 160

names prefixes from tera to pico,

establishes the supplementary units rad and sr,

lists some derived units

CIPM, 1969:  declarations concerning base, supplementary, 166

derived and coherent units, and the use of prefixes

CIPM, 2001:  “SI units” and “units of the SI” 177

23rd CGPM, 2007: possible redefinition of certain base units of the International 183

System of Units, the SI

24th CGPM, 2011: possible future revision of the International 186

System of Units, the SI

25th CGPM, 2014: future revision of the International System of Units, the SI 191

26th CGPM, 2018: revision of the International System of Units, the SI 194

(to enter into force on 20 May 2019)

Decisions relating to the base units of the SI

Length

1st CGPM, 1889: sanction of the prototype metre 153

7th CGPM, 1927: definition and use of the prototype metre 154

10th CGPM, 1954: metre adopted as a base unit 163

11th CGPM, 1960: redefinition of the metre in terms of krypton 86 radiation 159

15th CGPM, 1975: recommends value for the speed of light 168

17th CGPM, 1983: redefinition of the metre using the speed of light, 171

realization of the definition of the metre

CIPM, 2002:  specifies the rules for the practical realization of the 177

definition of the metre

CIPM, 2003:  revision of the list of recommended radiations 180

CIPM, 2005:  revision of the list of recommended radiations 181

CIPM, 2007:  revision of the list of recommended radiations 183

23th CGPM, 2007: revision of the mise en pratique of the definition of the metre 183

and development of new optical frequency standards

CIPM, 2009:  updates to the list of standard frequencies 185

24th CGPM, 2011: possible future revision of the International 186

System of Units, the SI

148  •  Appendix 1

page

24th CGPM, 2011: revision of the mise en pratique of the definition of the metre 190

and development of new optical frequency standards

CIPM, 2013:  updates to the list of standard frequencies 190

26th CGPM, 2018: revision of the International System of Units, the SI 194

(to enter into force on 20 May 2019)

Mass

1st CGPM, 1889: sanction of the prototype kilogram 153

3rd CGPM, 1901: declaration on distinguishing mass and weight, 154

and on the conventional value of gn

10th CGPM, 1954: kilogram adopted as a base unit 157

CIPM, 1967:  declaration on applying prefixes to the gram 163

21st CGPM, 1999: future redefinition of the kilogram 176

23rd CGPM, 2007: possible redefinition of certain base units of the 183

International System of Units (SI)

24th CGPM, 2011: possible future revision of the International System 186

of Units, the SI

25th CGPM, 2014: future revision of the International System of Units, the SI 191

26th CGPM, 2018: revision of the International System of Units, the SI 194

(to enter into force on 20 May 2019)

Time

10th CGPM, 1954: second adopted as a base unit 158

CIPM, 1956:  definition of the second as a fraction of the 158

tropical year 1900

11th CGPM, 1960: ratifies the CIPM 1956 definition of the second 159

CIPM, 1964:  declares the caesium 133 hyperfine transition 162

to be the recommended standard

12th CGPM, 1964: empowers CIPM to investigate atomic 162

and molecular frequency standards

13th CGPM, 1967/68: defines the second in terms of the caesium transition 164

CCDS, 1970:  defines International Atomic Time, TAI 166

14th CGPM, 1971: requests the CIPM to define and establish 167

International Atomic Time, TAI

15th CGPM, 1975: endorses the use of Coordinated Universal Time, UTC 168

CIPM, 2006:  secondary representations of the second 182

23rd CGPM, 2007: revision of the mise en pratique of the definition of the metre 183

and development of new optical frequency standards

CIPM, 2009:  updates to the list of standard frequencies 185

24th CGPM, 2011: possible future revision of the International System 186

of Units, the SI

24th CGPM, 2011: revision of the mise en pratique of the definition of the metre 190

and development of new optical frequency standards

Appendix 1  •  149

page

CIPM, 2013:  updates to the list of standard frequencies 190

CIPM, 2015:  updates to the list of standard frequencies 192

26th CGPM, 2018: revision of the International System of Units, the SI 194

(to enter into force on 20 May 2019)

Electrical units

CIPM, 1946:  definitions of coherent electrical units in the 155

metre-kilogram-second (MKS) system of units

(to enter into force on 1 January 1948)

10th CGPM, 1954: ampere adopted as a base unit 158

14th CGPM, 1971: adopts the name siemens, symbol S, for electrical 167

conductance

18th CGPM, 1987: forthcoming adjustment to the representations of 173

the volt and of the ohm

CIPM, 1988:  conventional value of the Josephson constant defined 174

(to enter into force on 1 January 1990)

CIPM, 1988:  conventional value of the von Klitzing constant defined 174

(to enter into force on 1 January 1990)

23rd CGPM, 2007: possible redefinition of certain base units of the 183

International System of Units (SI)

24th CGPM, 2011: possible future revision of the International System 186

of Units, the SI

25th CGPM, 2014: future revision of the International System of Units, the SI 191

26th CGPM, 2018: revision of the International System of Units, the SI 194

(to enter into force on 20 May 2019)

Thermodynamic temperature

9th CGPM, 1948: adopts the triple point of water as the thermodynamic 156

reference point, adopts the zero of Celsius temperature

to be 0.01 degrees below the triple point

CGPM, 1948:  adopts the name degree Celsius for the Celsius 157

temperature scale

10th CGPM, 1954: defines thermodynamic temperature such that the 157

triple point of water is 273.16 degrees Kelvin exactly,

defines standard atmosphere

10th CGPM, 1954: degree Kelvin adopted as a base unit 158

13th CGPM, 1967/68: decides formal definition of the kelvin, symbol K 164

CIPM, 1989:  the International Temperature Scale of 1990, ITS-90 175

CIPM, 2005:  note added to the definition of the kelvin concerning the 181

isotopic composition of water

23rd CGPM, 2007: clarification of the definition of the kelvin, unit of 184

thermodynamic temperature

23rd CGPM, 2007: possible redefinition of certain base units of the 183

International System of Units (SI)

24th CGPM, 2011: possible future revision of the International System 186

of Units, the SI

150  •  Appendix 1

page

25th CGPM, 2014: future revision of the International System of Units, the SI 191

26th CGPM, 2018: revision of the International System of Units, the SI 194

(to enter into force on 20 May 2019)

Amount of substance

14th CGPM, 1971: definition of the mole, symbol mol, as a seventh base unit, 168

and rules for its use

21st CGPM, 1999: adopts the special name katal, kat 177

23rd CGPM, 2007: on the possible redefinition of certain base units of the 183

International System of Units (SI)

24th CGPM, 2011: possible future revision of the International System 186

of Units, the SI

25th CGPM, 2014: future revision of the International System of Units, the SI 191

26th CGPM, 2018: revision of the International System of Units, the SI 194

(to enter into force on 20 May 2019)

Luminous intensity

CIPM, 1946:  definition of photometric units, new candle and new lumen 154

(to enter into force on 1 January 1948)

10th CGPM, 1954: candela adopted as a base unit 158

13th CGPM, 1967/68: defines the candela, symbol cd, in terms of a black body radiator 165

16th CGPM, 1979: redefines the candela in terms of monochromatic radiation 169

24th CGPM, 2011: possible future revision of the International System 186

of Units, the SI

26th CGPM, 2018: revision of the International System of Units, the SI 194

(to enter into force on 20 May 2019)

Decisions relating to SI derived and supplementary units

SI derived units

12th CGPM, 1964: accepts the continued use of the curie as a non-SI unit 163

13th CGPM, 1967/68: lists some examples of derived units 165

15th CGPM, 1975: adopts the special names becquerel, Bq, and gray, Gy 169

16th CGPM, 1979: adopts the special name sievert, Sv 170

CIPM, 1984:  decides to clarify the relationship between absorbed dose 173

(SI unit gray) and dose equivalent (SI unit sievert)

CIPM, 2002:  modifies the relationship between absorbed dose 179

and dose equivalent

Supplementary units

CIPM, 1980:  decides to interpret supplementary units 171

as dimensionless derived units

20th CGPM, 1995: decides to abrogate the class of supplementary units, 176

and confirms the CIPM interpretation that they are

dimensionless derived units

Appendix 1  •  151

Decisions concerning terminology and the acceptance of units for use with the SI page

SI prefixes

12th CGPM, 1964: decides to add femto and atto to the list of prefixes 163

15th CGPM, 1975: decides to add peta and exa to the list of prefixes 169

19th CGPM, 1991: decides to add zetta, zepto, yotta, and yocto to the 175

list of prefixes

27th CGPM, 2022:  decides to add ronna, ronto, quetta, and quecto to the 196

list of prefixes

Unit symbols and numbers

9th CGPM, 1948: decides rules for printing unit symbols 157

Unit names

13th CGPM, 1967/68: abrogates the use of the micron and new candle 166

as units accepted for use with the SI

The decimal marker

22nd CGPM, 2003: decides to allow the use of the point or the comma 180

on the line as the decimal marker

Units accepted for use with the SI: an example, the litre

3rd CGPM, 1901: defines the litre as the volume of 1 kg of water 153

11th CGPM, 1960: requests the CIPM to report on the difference 162

between the litre and the cubic decimetre

CIPM, 1961:  recommends that volume be expressed in SI units 162

and not in litres

12th CGPM, 1964: abrogates the former definition of the litre, 163

recommends that litre may be used as a special

name for the cubic decimetre

16th CGPM, 1979: decides, as an exception, to allow both l and L as 170

symbols for the litre

152  •  Appendix 1

### 1st CGPM, 1889

  Sanction of the international prototypes of the metre and the kilogram  (CR, 34 - 38)

The Conférence Générale des Poids et Mesures,

considering

## • the “Compte rendu of the President of the Comité International des Poids et Mesures (CIPM)”  and the “Report of the CIPM”, which show that, by the collaboration of the French section of  the International Metre Commission and of the CIPM, the fundamental measurements of the  international and national prototypes of the metre and of the kilogram have been made with  all the accuracy and reliability which the present state of science permits;

## • that the international and national prototypes of the metre and the kilogram are made of an  alloy of platinum with 10 per cent iridium, to within 0.0001;

## • the equality in length of the international Metre and the equality in mass of the international  Kilogram with the length of the Metre and the mass of the Kilogram kept in the Archives of  France;

## • that the differences between the national Metres and the international Metre lie within  0.01 millimetre and that these differences are based on a hydrogen thermometer scale which  can always be reproduced thanks to the stability of hydrogen, provided identical conditions  are secured;

## • that the differences between the national Kilograms and the international Kilogram lie within  1 milligram;

## • that the international Metre and Kilogram and the national Metres and Kilograms fulfil the  requirements of the Metre Convention,

sanctions

A. As regards international prototypes:

1\. The Prototype of the metre chosen by the CIPM. This prototype, at the temperature of melting  ice, shall henceforth represent the metric unit of length.

2\. The Prototype of the kilogram adopted by the CIPM. This prototype shall henceforth be  considered as the unit of mass.

3\. The hydrogen thermometer centigrade scale in terms of which the equations of the prototype  Metres have been established.

B. As regards national prototypes:

…

Note: The definition of the metre was abrogated in 1960 by the 11th CGPM (Resolution 6,  see p. 159). The definition of the kilogram was abrogated in 2018 by the 26th CGPM  (Resolution 1, see p. 194).

### 3rd CGPM, 1901

  Declaration concerning the definition of the litre (CR, 38-39)

…

The Conference declares

1\. The unit of volume, for high accuracy determinations, is the volume occupied by a mass of  1 kilogram of pure water, at its maximum density and at standard atmospheric pressure: this  volume is called “litre”.

2\. …

Note: This definition was abrogated in 1964 by the 12th CGPM (Resolution 6, see p. 163).

Appendix 1  •  153

  Declaration on the unit of mass and on the definition of weight; conventional  value of gn (CR, 70)

Taking into account the decision of the Comité International des Poids et Mesures of  15 October 1887, according to which the kilogram has been defined as unit of mass;

Taking into account the decision contained in the sanction of the prototypes of the Metric  System, unanimously accepted by the Conférence Générale des Poids et Mesures on  26 September 1889;

Considering the necessity to put an end to the ambiguity which in current practice still exists on  the meaning of the word weight, used sometimes for mass, sometimes for mechanical force;

The Conference declares

1\. The kilogram is the unit of mass; it is equal to the mass of the international prototype of the  kilogram;

2\. The word “weight” denotes a quantity of the same nature as a “force”: the weight of a body is  the product of its mass and the acceleration due to gravity; in particular, the standard weight  of a body is the product of its mass and the standard acceleration due to gravity;

3\. The value adopted in the International Service of Weights and Measures for the standard  acceleration due to gravity is 980.665 cm/s2, value already stated in the laws of some countries.

Note: The definition of the kilogram was abrogated in 2018 by the 26th CGPM  (Resolution 1, see p. 194).

The value for the standard acceleration due to gravity was the conventional reference for  calculating the now obsolete unit kilogram force.

### 7th CGPM, 1927

  Definition of the metre by the international Prototype (CR, 49)

The unit of length is the metre, defined by the distance, at 0°, between the axes of the two central  lines marked on the bar of platinum-iridium kept at the Bureau International des Poids et Mesures  and declared Prototype of the metre by the 1st Conférence Générale des Poids et Mesures, this  bar being subject to standard atmospheric pressure and supported on two cylinders of at least  one centimetre diameter, symmetrically placed in the same horizontal plane at a distance of  571 mm from each other.

Note: This definition was abrogated in 1960 by the 11th CGPM (Resolution 6, see p. 159).

### CIPM, 1946

  Definitions of photometric units (PV, 20, 119-122)

Resolution

…

4\. The photometric units may be defined as follows:

New candle (unit of luminous intensity). — The value of the new candle is such that the  brightness of the full radiator at the temperature of solidification of platinum is 60 new candles  per square centimetre.

New lumen (unit of luminous flux). — The new lumen is the luminous flux emitted in unit solid  angle (steradian) by a uniform point source having a luminous intensity of 1 new candle.

5\. …

Note: The two definitions contained in this Resolution were ratified in 1948 by the  9th CGPM, which also approved the name candela given to the “new candle” (CR, 54).  For the lumen the qualifier “new” was later abandoned. The definition of the candela was  modified in 1967 by the 13th CGPM (Resolution 5, see p. 165).

154  •  Appendix 1

  Definitions of electric units (PV, 20, 132-133)

Resolution 2

...

4\. (A) Definitions of the mechanical units which enter the definitions of electric units:

Unit of force. — The unit of force \[in the MKS (metre, kilogram, second) system\] is the force  which gives to a mass of 1 kilogram an acceleration of 1 metre per second, per second.

Joule (unit of energy or work). — The joule is the work done when the point of application of  1 MKS unit of force \[newton\] moves a distance of 1 metre in the direction of the force.

Watt (unit of power). — The watt is the power which in one second gives rise to energy of  1 joule.

(B) Definitions of electric units. The Comité International des Poids et Mesures (CIPM)  accepts the following propositions which define the theoretical value of the electric units:

Ampere (unit of electric current). — The ampere is that constant current which, if maintained in  two straight parallel conductors of infinite length, of negligible circular cross-section, and  placed 1 metre apart in vacuum, would produce between these conductors a force equal to  2 × 10−7 MKS unit of force \[newton\] per metre of length.

Volt (unit of potential difference and of electromotive force). — The volt is the potential difference  between two points of a conducting wire carrying a constant current of 1 ampere, when the  power dissipated between these points is equal to 1 watt.

Ohm (unit of electric resistance). — The ohm is the electric resistance between two points of a  conductor when a constant potential difference of 1 volt, applied to these points, produces in  the conductor a current of 1 ampere, the conductor not being the seat of any electromotive  force.

Coulomb (unit of quantity of electricity). — The coulomb is the quantity of electricity carried in  1 second by a current of 1 ampere.

Farad (unit of capacitance). — The farad is the capacitance of a capacitor between the plates of  which there appears a potential difference of 1 volt when it is charged by a quantity of  electricity of 1 coulomb.

Henry (unit of electric inductance). — The henry is the inductance of a closed circuit in which an  electromotive force of 1 volt is produced when the electric current in the circuit varies  uniformly at the rate of 1 ampere per second.

Weber (unit of magnetic flux). — The weber is the magnetic flux which, linking a circuit of one  turn, would produce in it an electromotive force of 1 volt if it were reduced to zero at a uniform  rate in 1 second.

Note: The definitions contained in this Resolution were ratified in 1948 by the 9th CGPM  (CR, 49), which also adopted the name newton (Resolution 7, see p. 157) for the MKS unit  of force.

In 1954, the 10th CGPM (Resolution 6, see p. 158) established a practical system of units  of measurement for international use. The ampere was designated as a base unit of this  system.

This definition of the ampere was abrogated in 2018 by the 26th CGPM (Resolution 1,  see p. 194).

Appendix 1  •  155

### 9th CGPM, 1948

  Triple point of water; thermodynamic scale with a single fixed point; unit of  quantity of heat (joule) (CR, 55 and 63)

Resolution 3

1\. With present-day techniques, the triple point of water is capable of providing a thermometric  reference point with an accuracy higher than can be obtained from the melting point of ice.

In consequence the Comité Consultatif de Thermométrie et Calorimétrie (CCTC) considers  that the zero of the centesimal thermodynamic scale must be defined as the temperature  0.0100 degree below that of the triple point of water.

2\. The CCTC accepts the principle of an absolute thermodynamic scale with a single  fundamental fixed point, at present provided by the triple point of pure water, the absolute  temperature of which will be fixed at a later date.

The introduction of this new scale does not affect in any way the use of the International  Scale, which remains the recommended practical scale.

3\. The unit of quantity of heat is the joule.

Note: It is requested that the results of calorimetric experiments be as far as possible expressed  in joules. If the experiments are made by comparison with the rise of temperature of water (and  that, for some reason, it is not possible to avoid using the calorie), the information necessary for  conversion to joules must be provided. The CIPM, advised by the CCTC, should prepare a table  giving, in joules per degree, the most accurate values that can be obtained from experiments on  the specific heat of water.

A table, prepared in response to this request, was approved and published by the CIPM in  1950 (PV, 22, 92).

Note: The kelvin was redefined by the 26th CGPM in 2018 (Resolution 1, see p. 194).

  Adoption of “degree Celsius” \[CIPM, 1948 (PV, 21, 88) and 9th CGPM, 1948  (CR, 64)\]

From three names (“degree centigrade”, “centesimal degree”, “degree Celsius”) proposed to  denote the degree of temperature, the CIPM has chosen “degree Celsius” (PV, 21, 88).

This name is also adopted by the 9th CGPM (CR, 64).

  Proposal for establishing a practical system of units of measurement (CR, 64)

Resolution 6

The Conférence Générale des Poids et Mesures (CGPM),

considering

## • that the Comité International des Poids et Mesures (CIPM) has been requested by the  International Union of Physics to adopt for international use a practical Système  International d’Unités; that the International Union of Physics recommends the MKS system  and one electric unit of the absolute practical system, but does not recommend that the  CGS system be abandoned by physicists;

## • that the CGPM has itself received from the French Government a similar request,  accompanied by a draft to be used as basis of discussion for the establishment of a  complete specification of units of measurement;

instructs the CIPM:

## • to seek by an energetic, active, official enquiry the opinion of scientific, technical and  educational circles of all countries (offering them, in fact, the French document as basis);

## • to gather and study the answers;

## • to make recommendations for a single practical system of units of measurement, suitable  for adoption by all countries adhering to the Metre Convention.

156  •  Appendix 1

  Writing and printing of unit symbols and of numbers (CR, 70)

Resolution 7

Principles

Roman (upright) type, in general lower-case, is used for symbols of units; if, however, the  symbols are derived from proper names, capital roman type is used. These symbols are not  followed by a full stop.

In numbers, the comma (French practice) or the dot (British practice) is used only to separate the  integral part of numbers from the decimal part. Numbers may be divided in groups of three in order  to facilitate reading; neither dots nor commas are ever inserted in the spaces between groups.

Unit  Symbol Unit Symbol

• metre m ampere A

• square metre m2 volt V

• cubic metre m3 watt W

• micron µ ohm Ω

• litre   l coulomb C

• gram  g farad F

• tonne t henry H

second s hertz Hz

erg   erg poise P

dyne  dyn newton N

degree Celsius °C • candela (new candle) cd

• degree absolute °K lux lx

calorie  cal lumen lm

bar   bar stilb sb

hour  h

Notes

1\. The symbols whose unit names are preceded by dots are those which had already been  adopted by a decision of the CIPM.

2\. The symbol for the stere, the unit of volume for firewood, shall be “st” and not “s”, which had  been previously assigned to it by the CIPM.

3\. To indicate a temperature interval or difference, rather than a temperature, the word “degree”  in full, or the abbreviation “deg”, must be used.

Note: The CGPM abrogated certain decisions on units and terminology, in particular:  micron, degree absolute, and the terms “degree”, and “deg”, 13th CGPM, 1967/68  (Resolutions 7 and 3, see pp. 166 and 164, respectively), and the litre; 16th CGPM, 1979  (Resolution 6, see p. 170).

### 10th CGPM, 1954

  Definition of the thermodynamic temperature scale (CR, 79)

Resolution 3

The 10th Conférence Générale des Poids et Mesures decides to define the thermodynamic  temperature scale by choosing the triple point of water as the fundamental fixed point, and  assigning to it the temperature 273.16 degrees Kelvin, exactly.

Appendix 1  •  157

Note: The 13th CGPM in 1967 explicitly defined the kelvin (Resolution 4, see p. 165). The  kelvin was redefined by the 26th CGPM in 2018 (Resolution 1, see p. 194).

  Definition of the standard atmosphere (CR, 79)

Resolution 4

The 10th Conférence Générale des Poids et Mesures (CGPM), having noted that the definition of  the standard atmosphere given by the 9th CGPM when defining the International Temperature  Scale led some physicists to believe that this definition of the standard atmosphere was valid  only for accurate work in thermometry,

declares that it adopts, for general use, the definition:

1 standard atmosphere = 1 013 250 dynes per square centimetre,

i.e., 101 325 newtons per square metre.

  Practical system of units (CR, 80)

Resolution 6

In accordance with the wish expressed by the 9th Conférence Générale des Poids et Mesures  (CGPM) in its Resolution 6 concerning the establishment of a practical system of units of  measurement for international use, the 10th CGPM

decides to adopt as base units of the system, the following units:

length      metre

mass      kilogram

time      second

electric current     ampere

thermodynamic temperature   degree Kelvin

luminous intensity    candela

Note: The unit name “degree kelvin” was changed to “kelvin” in 1967 by the 13th CGPM  (Resolution 3, see p. 164).

### CIPM, 1956

  Definition of the unit of time (second) (PV, 25, 77)

Resolution 1

In virtue of the powers invested in it by Resolution 5 of the 10th Conférence Générale des Poids  et Mesures, the Comité International des Poids et Mesures,

considering

1\. that the 9th General Assembly of the International Astronomical Union (Dublin, 1955)  declared itself in favour of linking the second to the tropical year,

2\. that, according to the decisions of the 8th General Assembly of the International Astronomical  Union (Rome, 1952), the second of ephemeris time (ET) is the fraction

× 10−9 of the tropical year for 1900 January 0 at 12 h ET,

496986408 81327696012

decides

“The second is the fraction 1/31 556 925.9747 of the tropical year for 1900 January 0 at 12 hours  ephemeris time.”

Note: This definition was abrogated in 1967 by the 13th CGPM (Resolution 1, see p. 164).

158  •  Appendix 1

  Système International d’Unités (PV, 25, 83)

Resolution 3

The Comité International des Poids et Mesures,

considering

## • the task entrusted to it by Resolution 6 of the 9th Conférence Générale des Poids et Mesures  (CGPM) concerning the establishment of a practical system of units of measurement suitable  for adoption by all countries adhering to the Metre Convention,

## • the documents received from twenty-one countries in reply to the enquiry requested by the  9th CGPM,

## • Resolution 6 of the 10th CGPM, fixing the base units of the system to be established,

recommends

1\. that the name “Système International d’Unités” be given to the system founded on the base  units adopted by the 10th CGPM, viz.:

\[This is followed by the list of the six base units with their symbols, reproduced in  Resolution 12 of the 11th CGPM (1960)\].

2\. that the units listed in the table below be used, without excluding others which might be  added later:

\[This is followed by the table of units reproduced in paragraph 4 of Resolution 12 of the  11th CGPM (1960)\].

### 11th CGPM, 1960

  Definition of the metre (CR, 85)

Resolution 6

The 11th Conférence Générale des Poids et Mesures (CGPM),

considering

## • that the international Prototype does not define the metre with an accuracy adequate for the  present needs of metrology,

## • that it is moreover desirable to adopt a natural and indestructible standard,

decides

1\. The metre is the length equal to 1 650 763.73 wavelengths in vacuum of the radiation  corresponding to the transition between the levels 2p10 and 5d5 of the krypton 86 atom.

2\. The definition of the metre in force since 1889, based on the international Prototype of  platinum-iridium, is abrogated.

3\. The international Prototype of the metre sanctioned by the 1st CGPM in 1889 shall be kept at  the BIPM under the conditions specified in 1889.

Note: This definition was abrogated in 1983 by the 17th CGPM (Resolution 1, see p. 171).

  Definition of the unit of time (second) (CR, 86)

Resolution 9

The 11th Conférence Générale des Poids et Mesures (CGPM),

considering

## • the powers given to the Comité International des Poids et Mesures (CIPM) by the 10th CGPM  to define the fundamental unit of time,

## • the decision taken by the CIPM in 1956,

ratifies the following definition:

Appendix 1  •  159

“The second is the fraction 1/31 556 925.9747 of the tropical year for 1900 January 0 at 12 hours  ephemeris time.”

Note: This definition was abrogated in 1967 by the 13th CGPM (Resolution 1, see p. 164).

  Système International d’Unités (CR, 87)

Resolution 12

The 11th Conférence Générale des Poids et Mesures (CGPM),

considering

## • Resolution 6 of the 10th CGPM, by which it adopted six base units on which to establish a  practical system of measurement for international use:

length    metre m

mass    kilogram kg

time    second s

electric current   ampere A

thermodynamic temperature  degree Kelvin °K

luminous intensity  candela cd

## • Resolution 3 adopted by the Comité International des Poids et Mesures (CIPM) in 1956,

## • the recommendations adopted by the CIPM in 1958 concerning an abbreviation for the  name of the system, and prefixes to form multiples and submultiples of the units,

decides

1\. the system founded on the six base units above is called the “Système International  d’Unités”;

2\. the international abbreviation of the name of the system is: SI;

3\. names of multiples and submultiples of the units are formed by means of the following  prefixes:

Multiplying factor   Prefix    Symbol Multiplying factor         Prefix  Symbol

1 000 000 000 000 = 1012 tera T  0.1 = 10−1  deci d

1 000 000 000 = 109  giga G 0.01 = 10−2  centi c

1 000 000 = 106  mega M 0.001 = 10−3  milli m

1 000 = 103  kilo k 0.000 001 = 10−6  micro µ

100 = 102  hecto h 0.000 000 001 = 10−9  nano n

10 = 101  deca da 0.000 000 000 001 = 10−12 pico p

4\. the units listed below are used in the system, without excluding others which might be added  later.

Supplementary units

plane angle   radian rad

solid angle   steradian sr

Derived units

area   square metre m2

volume  cubic metre m3

160  •  Appendix 1

frequency  hertz Hz 1/s

mass density (density)  kilogram per cubic metre kg/m3

speed, velocity  metre per second m/s

angular velocity  radian per second rad/s

acceleration  metre per second squared m/s2

angular acceleration  radian per second squared rad/s2

force   newton N kg · m/s2

pressure (mechanical stress)  newton per square metre N/m2

kinematic viscosity  square metre per second m2/s

dynamic viscosity  newton-second per square

metre N · s/m2

work, energy, quantity of heat joule J N · m

power   watt W J/s

quantity of electricity  coulomb C A · s

tension (voltage),     potential difference,     electromotive force  volt V W/A

electric field strength  volt per metre V/m

electric resistance  ohm Ω V/A

capacitance  farad F A · s/V

magnetic flux   weber Wb V · s

inductance  henry H V · s/A

magnetic flux density  tesla T Wb/m2

magnetic field strength  ampere per metre A/m

magnetomotive force  ampere A

luminous flux   lumen lm cd · sr

luminance  candela per square metre cd/m2

illuminance  lux lx lm/m2

Note: The CGPM later abrogated certain of its decisions and extended the list of prefixes,  see notes below.

The name and symbol for the unit of thermodynamic temperature was modified by the  13th CGPM in 1967 (Resolution 3, see p. 164).

A seventh base unit, the mole, was adopted by the 14th CGPM in 1971 (Resolution 3,  see p. 168).

Further prefixes were adopted by the 12th CGPM in 1964 (Resolution 8, see p. 163), the  15th CGPM in 1975 (Resolution 10, see p. 169), the 19th CGPM in 1991 (Resolution 4,  see p. 175) and the 27th CGPM in 2022 (Resolution 3, see p. 196).

The 20th CGPM in 1995 abrogated the class of supplementary units in the SI (Resolution 8,  see p. 176). These are now considered as derived units.

The 13th CGPM in 1967 (Resolution 6, see p. 165) specified other units which should be  added to the list of derived units. In principle, this list of derived units is without limit.

Modern practice is to use the phrase “amount of heat” rather than “quantity of heat”,  because the word quantity has a different meaning in metrology.

Modern practice is to use the phrase “amount of electricity” rather than “quantity of  electricity” (see note above).

Appendix 1  •  161

  Cubic decimetre and litre (CR, 88)

Resolution 13

The 11th Conférence Générale des Poids et Mesures (CGPM),

considering

## • that the cubic decimetre and the litre are unequal and differ by about 28 parts in 106,

## • that determinations of physical quantities which involve measurements of volume are being  made more and more accurately, thus increasing the risk of confusion between the cubic  decimetre and the litre,

requests the Comité International des Poids et Mesures to study the problem and submit its  conclusions to the 12th CGPM.

### CIPM, 1961

  Cubic decimetre and litre (PV, 29, 34)

Recommendation

The Comité International des Poids et Mesures recommends that the results of accurate  measurements of volume be expressed in units of the International System and not in litres.

### CIPM, 1964

  Atomic and molecular frequency standards (PV, 32, 26)

Declaration

The Comité International des Poids et Mesures,

empowered by Resolution 5 of the 12th Conférence Générale des Poids et Mesures to name  atomic or molecular frequency standards for temporary use for time measurements in physics,

declares that the standard to be employed is the transition between the hyperfine levels F = 4,  M = 0 and F = 3, M = 0 of the ground state 2S1/2 of the caesium 133 atom, unperturbed by  external fields, and that the frequency of this transition is assigned the value 9 192 631 770 hertz.

### 12th CGPM, 1964

  Atomic standard of frequency (CR, 93)

Resolution 5

The 12th Conférence Générale des Poids et Mesures (CGPM),

considering

## • that the 11th CGPM noted in its Resolution 10 the urgency, in the interests of accurate  metrology, of adopting an atomic or molecular standard of time interval,

## • that, in spite of the results already obtained with caesium atomic frequency standards, the  time has not yet come for the CGPM to adopt a new definition of the second, base unit of the  Système International d’Unités, because of the new and considerable improvements likely to  be obtained from work now in progress,

considering also that it is not desirable to wait any longer before time measurements in physics  are based on atomic or molecular frequency standards,

empowers the Comité International des Poids et Mesures to name the atomic or molecular  frequency standards to be employed for the time being,

requests the organizations and laboratories knowledgeable in this field to pursue work  connected with a new definition of the second.

162  •  Appendix 1

  Litre (CR, 93)

Resolution 6

The 12th Conférence Générale des Poids et Mesures (CGPM),

considering Resolution 13 adopted by the 11th CGPM in 1960 and the Recommendation  adopted by the Comité International des Poids et Mesures in 1961,

1\. abrogates the definition of the litre given in 1901 by the 3rd CGPM,

2\. declares that the word “litre” may be employed as a special name for the cubic decimetre,

3\. recommends that the name litre should not be employed to give the results of high-accuracy  volume measurements.

  Curie (CR, 94)

Resolution 7

The 12th Conférence Générale des Poids et Mesures,

considering that the curie has been used for a long time in many countries as unit of activity for  radionuclides,

recognizing that in the Système International d’Unités (SI), the unit of this activity is the second  to the power of minus one (s−1),

accepts that the curie be still retained, outside SI, as unit of activity, with the value 3.7 × 1010 s−1.  The symbol for this unit is Ci.

Note: The name “becquerel” (Bq) was adopted by the 15th CGPM in 1975 (Resolution 8,  see p. 169) for the SI unit of activity: 1 Ci = 3.7 × 1010 Bq.

  SI prefixes femto and atto (CR, 94)

Resolution 8

The 12th Conférence Générale des Poids et Mesures (CGPM)

decides to add to the list of prefixes for the formation of names of multiples and submultiples of  units, adopted by the 11th CGPM, Resolution 12, paragraph 3, the following two new prefixes:

Multiplying factor  Prefix Symbol

10−15   femto f

10−18  atto a

Note: New prefixes were added by the 15th CGPM in 1975 (Resolution 10, see p. 169), the  19th CGPM in 1991 (Resolution 4, see p. 175) and the 27th CGPM in 2022 (Resolution 3,  see p. 196).

### CIPM, 1967

  Decimal multiples and submultiples of the unit of mass (PV, 35, 29 and  Metrologia, 1968, 4, 45)

Recommendation 2

The Comité International des Poids et Mesures,

considering that the rule for forming names of decimal multiples and submultiples of the units of  paragraph 3 of Resolution 12 of the 11th Conférence Générale des Poids et Mesures (CGPM)  (1960) might be interpreted in different ways when applied to the unit of mass,

declares that the rules of Resolution 12 of the 11th CGPM apply to the kilogram in the following  manner: the names of decimal multiples and submultiples of the unit of mass are formed by  attaching prefixes to the word “gram”.

Appendix 1  •  163

### 13th CGPM, 1967/68

  SI unit of time (second) (CR, 103 and Metrologia, 1968, 4, 43)

Resolution 1

The 13th Conférence Générale des Poids et Mesures (CGPM),

considering

## • that the definition of the second adopted by the Comité International des Poids et Mesures  (CIPM) in 1956 (Resolution 1) and ratified by Resolution 9 of the 11th CGPM (1960), later  upheld by Resolution 5 of the 12th CGPM (1964), is inadequate for the present needs of  metrology,

## • that at its meeting of 1964 the CIPM, empowered by Resolution 5 of the 12th CGPM (1964),  recommended, in order to fulfil these requirements, a caesium atomic frequency standard for  temporary use,

## • that this frequency standard has now been sufficiently tested and found sufficiently accurate  to provide a definition of the second fulfilling present requirements,

## • that the time has now come to replace the definition now in force of the unit of time of the  Système International d’Unités by an atomic definition based on that standard,

decides

1\. The SI unit of time is the second defined as follows:

“The second is the duration of 9 192 631 770 periods of the radiation corresponding to the  transition between the two hyperfine levels of the ground state of the caesium 133 atom”;

2\. Resolution 1 adopted by the CIPM at its meeting of 1956 and Resolution 9 of the 11th CGPM  are now abrogated.

Note: At its 1997 meeting, the CIPM affirmed that this definition refers to a caesium atom  at rest at a thermodynamic temperature of 0 K.

The wording of the definition of the second was modified by the 26th CGPM in 2018  (Resolution 1, see p. 194).

  SI unit of thermodynamic temperature (kelvin) (CR, 104 and Metrologia, 1968, 4, 43)

Resolution 3

The 13th Conférence Générale des Poids et Mesures (CGPM),

considering

## • the names “degree Kelvin” and “degree”, the symbols “°K” and “deg” and the rules for their  use given in Resolution 7 of the 9th CGPM (1948), in Resolution 12 of the 11th CGPM  (1960), and the decision taken by the Comité International des Poids et Mesures in 1962  (PV, 30, 27),

## • that the unit of thermodynamic temperature and the unit of temperature interval are one and  the same unit, which ought to be denoted by a single name and a single symbol,

decides

1\. the unit of thermodynamic temperature is denoted by the name “kelvin” and its symbol is “K”;

2\. the same name and the same symbol are used to express a temperature interval;

3\. a temperature interval may also be expressed in degrees Celsius;

4\. the decisions mentioned in the opening paragraph concerning the name of the unit of thermo- dynamic temperature, its symbol and the designation of the unit to express an interval or a  difference of temperatures are abrogated, but the usages which derive from these decisions  remain permissible for the time being.

Note: At its 1980 meeting, the CIPM approved the report of the 7th meeting of the CCU,  which requested that the use of the symbols “°K” and “deg” no longer be permitted.

See Recommendation 2 (CI-2005) of the CIPM on the isotopic composition of water  entering in the definition of the kelvin, p. 181.

164  •  Appendix 1

  Definition of the SI unit of thermodynamic temperature (kelvin) (CR, 104 and  Metrologia, 1968, 4, 43)

Resolution 4

The 13th Conférence Générale des Poids et Mesures (CGPM),

considering that it is useful to formulate more explicitly the definition of the unit of  thermodynamic temperature contained in Resolution 3 of the 10th CGPM (1954),

decides to express this definition as follows:

“The kelvin, unit of thermodynamic temperature, is the fraction 1/273.16 of the thermodynamic  temperature of the triple point of water.”

Note: See Recommendation 5 (CI-1989) of the CIPM on the International Temperature  Scale of 1990, p. 175.

The kelvin was redefined by the 26th CGPM in 2018 (Resolution 1, see p. 194).

  SI unit of luminous intensity (candela) (CR, 104 and Metrologia, 1968, 4, 43-44)

Resolution 5

The 13th Conférence Générale des Poids et Mesures (CGPM),

considering

## • the definition of the unit of luminous intensity ratified by the 9th CGPM (1948) and contained  in the “Resolution concerning the change of photometric units” adopted by the Comité  International des Poids et Mesures in 1946 (PV, 20, 119) in virtue of the powers conferred  by the 8th CGPM (1933),

## • that this definition fixes satisfactorily the unit of luminous intensity, but that its wording may  be open to criticism,

decides to express the definition of the candela as follows:

“The candela is the luminous intensity, in the perpendicular direction, of a surface of  1/600 000 square metre of a black body at the temperature of freezing platinum under a pressure  of 101 325 newtons per square metre.”

Note: This definition was abrogated by the 16th CGPM in 1979 (Resolution 3, see p. 169).

  SI derived units (CR, 105 and Metrologia, 1968, 4, 44)

Resolution 6

The 13th Conférence Générale des Poids et Mesures (CGPM),

considering that it is useful to add some derived units to the list of paragraph 4 of Resolution 12  of the 11th CGPM (1960),

decides to add:

wave number     1 per metre  m−1

entropy     joule per kelvin  J/K

specific heat capacity    joule per kilogram kelvin J/(kg · K)

thermal conductivity    watt per metre kelvin  W/(m · K)

radiant intensity     watt per steradian  W/sr

activity (of a radioactive source)  1 per second  s−1

Note: The unit of activity was given a special name and symbol by the 15th CGPM in 1975  (Resolution 8, see p. 169).

Appendix 1  •  165

  Abrogation of earlier decisions (micron and new candle) (CR, 105 and  Metrologia, 1968, 4, 44)

Resolution 7

The 13th Conférence Générale des Poids et Mesures (CGPM),

considering that subsequent decisions of the General Conference concerning the Système  International d’Unités are incompatible with parts of Resolution 7 of the 9th CGPM (1948),

decides accordingly to remove from Resolution 7 of the 9th Conference:

1\. the unit name “micron”, and the symbol “µ” which had been given to that unit but which has  now become a prefix;

2\. the unit name “new candle”.

### CIPM, 1969

  Système International d’Unités, Rules for application of Resolution 12 of the  11th CGPM (1960) (PV, 37, 30 and Metrologia, 1970, 6, 66)

Recommendation 1

The Comité International des Poids et Mesures,

considering that Resolution 12 of the 11th Conférence Générale des Poids et Mesures (CGPM)  (1960), concerning the Système International d’Unités, has provoked discussions on certain of its  aspects,

declares

1\. the base units, the supplementary units and the derived units of the Système International  d’Unités, which form a coherent set, are denoted by the name “SI units”;

2\. the prefixes adopted by the CGPM for the formation of decimal multiples and submultiples of  SI units are called “SI prefixes”;

and recommends

3\. the use of SI units and of their decimal multiples and submultiples whose names are formed  by means of SI prefixes.

Note: The name “supplementary units”, appearing in Resolution 12 of the 11th CGPM (and in the  present Recommendation) is given to SI units for which the General Conference declines to state  whether they are base units or derived units.

Note: The 20th CGPM in 1995 decided to abrogate the class of supplementary units in the  SI (Resolution 8, see p. 176).

The CIPM approved in 2001 a proposal of the CCU to clarify the definition of “SI units”  and “units of the SI”, see p. 177.

### CCDS, 1970 (In CIPM, 1970)

  Definition of TAI (PV, 38, 110-111 and Metrologia, 1971, 7, 43)

Recommendation S 2

International Atomic Time (TAI) is the time reference coordinate established by the Bureau  International de l'Heure on the basis of the readings of atomic clocks operating in various  establishments in accordance with the definition of the second, the unit of time of the  International System of Units.

In 1980, the definition of TAI was completed as follows (declaration of the CCDS, BIPM  Com. Cons. Déf. Seconde, 1980, 9, S 15 and Metrologia, 1981, 17, 70):

TAI is a coordinate time scale defined in a geocentric reference frame with the SI second as  realized on the rotating geoid as the scale unit.

Note: This definition was further amplified by the International Astronomical Union in 1991,  Resolution A4:

166  •  Appendix 1

“TAI is a realized time scale whose ideal form, neglecting a constant offset of 32.184 s,  is Terrestrial Time (TT), itself related to the time coordinate of the geocentric reference  frame, Geocentric Coordinate Time (TCG), by a constant rate.”

(see Proc. 21st General Assembly of the IAU, IAU Trans., 1991, vol. XXIB, Kluwer.)

### 14th CGPM, 1971

  Pascal and siemens (CR, 78)

The 14th Conférence Générale des Poids et Mesures adopted the special names “pascal”  (symbol Pa), for the SI unit newton per square metre, and “siemens” (symbol S), for the SI unit of  electric conductance \[reciprocal ohm\].

  International Atomic Time, function of CIPM (CR, 77-78 and Metrologia, 1972, 8, 35)

Resolution 1

The 14th Conférence Générale des Poids et Mesures (CGPM),

considering

## • that the second, unit of time of the Système International d’Unités, has since 1967 been  defined in terms of a natural atomic frequency, and no longer in terms of the time scales  provided by astronomical motions,

## • that the need for an International Atomic Time (TAI) scale is a consequence of the atomic  definition of the second,

## • that several international organizations have ensured and are still successfully ensuring the  establishment of the time scales based on astronomical motions, particularly thanks to the  permanent services of the Bureau International de l'Heure (BIH),

## • that the BIH has started to establish an atomic time scale of recognized quality and proven  usefulness,

## • that the atomic frequency standards for realizing the second have been considered and  must continue to be considered by the Comité International des Poids et Mesures (CIPM)  helped by a Consultative Committee, and that the unit interval of the International Atomic  Time scale must be the second realized according to its atomic definition,

## • that all the competent international scientific organizations and the national laboratories  active in this field have expressed the wish that the CIPM and the CGPM should give a  definition of International Atomic Time, and should contribute to the establishment of the  International Atomic Time scale,

## • that the usefulness of International Atomic Time entails close coordination with the time  scales based on astronomical motions,

requests the CIPM

1\. to give a definition of International Atomic Time,

2\. to take the necessary steps, in agreement with the international organizations concerned, to  ensure that available scientific competence and existing facilities are used in the best  possible way to realize the International Atomic Time scale and to satisfy the requirements of  users of International Atomic Time.

Note: The definition of TAI was given by the CCDS in 1970 (now the CCTF), see CCDS  report p. 22.

Appendix 1  •  167

  SI unit of amount of substance (mole) (CR, 78 and Metrologia, 1972, 8, 36)

Resolution 3

The 14th Conférence Générale des Poids et Mesures (CGPM),

considering the advice of the International Union of Pure and Applied Physics, of the  International Union of Pure and Applied Chemistry, and of the International Organization for  Standardization, concerning the need to define a unit of amount of substance,

decides

1\. The mole is the amount of substance of a system which contains as many elementary entities  as there are atoms in 0.012 kilogram of carbon 12; its symbol is “mol”.

2\. When the mole is used, the elementary entities must be specified and may be atoms,  molecules, ions, electrons, other particles, or specified groups of such particles.

3\. The mole is a base unit of the Système International d’Unités.

Note: At its 1980 meeting, the CIPM approved the report of the 7th meeting of the CCU  (1980) specifying that, in this definition, it is understood that unbound atoms of carbon 12,  at rest and in their ground state, are referred to.

The mole was redefined by the 26th CGPM in 2018 (Resolution 1, see p. 194).

### 15th CGPM, 1975

  Recommended value for the speed of light (CR, 103 and Metrologia, 1975, 11,  179-180)

Resolution 2

The 15th Conférence Générale des Poids et Mesures,

considering the excellent agreement among the results of wavelength measurements on the  radiations of lasers locked on a molecular absorption line in the visible or infrared region, with an  uncertainty estimated at ± 4 × 10−9 which corresponds to the uncertainty of the realization of the  metre,

considering also the concordant measurements of the frequencies of several of these  radiations,

recommends the use of the resulting value for the speed of propagation of electromagnetic  waves in vacuum c = 299 792 458 metres per second.

Note: The relative uncertainty given here corresponds to three standard deviations  in the data considered.

  Coordinated Universal Time (UTC) (CR, 104 and Metrologia, 1975, 11, 180)

Resolution 5

The 15th Conférence Générale des Poids et Mesures,

considering that the system called “Coordinated Universal Time” (UTC) is widely used, that it is  broadcast in most radio transmissions of time signals, that this wide diffusion makes available to  the users not only frequency standards but also International Atomic Time and an approximation  to Universal Time (or, if one prefers, mean solar time),

notes that this Coordinated Universal Time provides the basis of civil time, the use of which is  legal in most countries,

judges that this usage can be strongly endorsed.

168  •  Appendix 1

  SI units for ionizing radiation (becquerel and gray) (CR, 105 and Metrologia,  1975, 11, 180)

Resolutions 8 and 9

The 15th Conférence Générale des Poids et Mesures,

by reason of the pressing requirement, expressed by the International Commission on Radiation  Units and Measurements (ICRU), to extend the use of the Système International d’Unités to  radiological research and applications,

by reason of the need to make as easy as possible the use of the units for nonspecialists,

taking into consideration also the grave risks of errors in therapeutic work,

adopts the following special name for the SI unit of activity:

becquerel, symbol Bq, equal to one reciprocal second  (Resolution 8),

adopts the following special name for the SI unit of ionizing radiation:

gray, symbol Gy, equal to one joule per kilogram (Resolution 9).

Note:  The gray is the SI unit of absorbed dose. In the field of ionizing radiation, the gray may be  used with other physical quantities also expressed in joules per kilogram: the Comité Consultatif  des Unités has responsibility for studying this matter in collaboration with the competent  international organizations.

Note: At its 1976 meeting, the CIPM approved the report of the 5th meeting of the CCU  (1976), specifying that, following the advice of the ICRU, the gray may also be used to  express specific energy imparted, kerma and absorbed dose index.

  SI prefixes peta and exa (CR, 106 and Metrologia, 1975, 11, 180-181)

Resolution 10

The 15th Conférence Générale des Poids et Mesures (CGPM)

decides to add to the list of SI prefixes to be used for multiples, which was adopted by the  11th CGPM, Resolution 12, paragraph 3, the two following prefixes:

Multiplying factor  Prefix  Symbol

1015   peta  P

1018   exa  E

Note: New prefixes were added by the 19th CGPM in 1991 (Resolution 4, see p. 175) and  by the 27th CGPM in 2022 (Resolution 3, see p. 196).

### 16th CGPM, 1979

  SI unit of luminous intensity (candela) (CR, 100 and Metrologia, 1980, 16, 56)

Resolution 3

The 16th Conférence Générale des Poids et Mesures (CGPM),

considering

## • that despite the notable efforts of some laboratories there remain excessive divergences  between the results of realizations of the candela based upon the present black body  primary standard,

## • that radiometric techniques are developing rapidly, allowing precisions that are already  equivalent to those of photometry and that these techniques are already in use in national  laboratories to realize the candela without having to construct a black body,

## • that the relation between luminous quantities of photometry and radiometric quantities,  namely the value of 683 lumens per watt for the spectral luminous efficacy of  monochromatic radiation of frequency 540 × 1012 hertz, has been adopted by the Comité  International des Poids et Mesures (CIPM) in 1977,

Appendix 1  •  169

## • that this value has been accepted as being sufficiently accurate for the system of luminous  photopic quantities, that it implies a change of only about 3 % for the system of luminous  scotopic quantities, and that it therefore ensures satisfactory continuity,

## • that the time has come to give the candela a definition that will allow an improvement in  both the ease of realization and the precision of photometric standards, and that applies to  both photopic and scotopic photometric quantities and to quantities yet to be defined in the  mesopic field,

decides

1\. The candela is the luminous intensity, in a given direction, of a source that emits  monochromatic radiation of frequency 540 × 1012 hertz and that has a radiant intensity in that  direction of 1/683 watt per steradian.

2\. The definition of the candela (at the time called new candle) adopted by the CIPM in 1946 by  reason of the powers conferred by the 8th CGPM in 1933, ratified by the 9th CGPM in 1948,  then amended by the 13th CGPM in 1967, is abrogated.

Note: The wording of the definition of the candela was modified by the 26th CGPM in 2018  (Resolution 1, see p. 194).

Photopic vision is detected by the cones on the retina of the eye, which are sensitive to a  high level of luminance (L \> ca. 10 cd/m2) and are used in daytime vision.

Scotopic vision is detected by the rods of the retina, which are sensitive to low level  luminance (L \< ca. 10−3 cd/m2), used in night vision.

In the domain between these levels of luminance both cones and rods are used, and this is  described as mesopic vision.

  Special name for the SI unit of dose equivalent (sievert) (CR, 100 and  Metrologia, 1980, 16, 56)

Resolution 5

The 16th Conférence Générale des Poids et Mesures,

considering

## • the effort made to introduce SI units into the field of ionizing radiations,

## • the risk to human beings of an underestimated radiation dose, a risk that could result from a  confusion between absorbed dose and dose equivalent,

## • that the proliferation of special names represents a danger for the Système International  d’Unités and must be avoided in every possible way, but that this rule can be broken when it  is a matter of safeguarding human health,

adopts the special name sievert, symbol Sv, for the SI unit of dose equivalent in the field of  radioprotection. The sievert is equal to the joule per kilogram.

Note: The CIPM, in 1984, decided to accompany this Resolution with an explanation  (Recommendation 1, see p. 173).

  Symbols for the litre (CR, 101 and Metrologia, 1980, 16, 56-57)

Resolution 6

The 16th Conférence Générale des Poids et Mesures (CGPM),

recognizing the general principles adopted for writing the unit symbols in Resolution 7 of the  9th CGPM (1948),

considering that the symbol l for the unit litre was adopted by the Comité International des Poids  et Mesures (CIPM) in 1879 and confirmed in the same Resolution of 1948,

considering also that, in order to avoid the risk of confusion between the letter l and the number  1, several countries have adopted the symbol L instead of l for the unit litre,

170  •  Appendix 1

considering that the name litre, although not included in the Système International d’Unités,  must be admitted for general use with the System,

decides, as an exception, to adopt the two symbols l and L as symbols to be used for the unit  litre,

considering further that in the future only one of these two symbols should be retained,

invites the CIPM to follow the development of the use of these two symbols and to give the  18th CGPM its opinion as to the possibility of suppressing one of them.

Note: The CIPM, in 1990, considered that it was still too early to choose a single symbol  for the litre.

### CIPM, 1980

  SI supplementary units (radian and steradian) (PV, 48, 24 and Metrologia, 1981,  17, 72)

Recommendation 1

The Comité International des Poids et Mesures (CIPM),

taking into consideration Resolution 3 adopted by ISO/TC 12 in 1978 and Recommen- dation U 1 (1980) adopted by the Comité Consultatif des Unités at its 7th meeting,

considering

## • that the units radian and steradian are usually introduced into expressions for units when  there is need for clarification, especially in photometry where the steradian plays an  important role in distinguishing between units corresponding to different quantities,

## • that in the equations used one generally expresses plane angle as the ratio of two lengths  and solid angle as the ratio between an area and the square of a length, and consequently  that these quantities are treated as dimensionless quantities,

## • that the study of the formalisms in use in the scientific field shows that none exists which is  at the same time coherent and convenient and in which the quantities plane angle and solid  angle might be considered as base quantities,

considering also

## • that the interpretation given by the CIPM in 1969 for the class of supplementary units  introduced in Resolution 12 of the 11th Conférence Générale des Poids et Mesures (CGPM)  in 1960 allows the freedom of treating the radian and the steradian as SI base units,

## • that such a possibility compromises the internal coherence of the SI based on only seven  base units,

decides to interpret the class of supplementary units in the International System as a class of  dimensionless derived units for which the CGPM allows the freedom of using or not using them in  expressions for SI derived units.

Note: The class of SI supplementary units was abrogated by decision of the 20th CGPM in  1995 (Resolution 8, see p. 176).

### 17th CGPM, 1983

  Definition of the metre (CR, 97 and Metrologia, 1984, 20, 25)

Resolution 1

The 17th Conférence Générale des Poids et Mesures (CGPM),

considering

## • that the present definition does not allow a sufficiently precise realization of the metre  for all requirements,

Appendix 1  •  171

## • that progress made in the stabilization of lasers allows radiations to be obtained that are  more reproducible and easier to use than the standard radiation emitted by a krypton  86 lamp,

## • that progress made in the measurement of the frequency and wavelength of these  radiations has resulted in concordant determinations of the speed of light whose  accuracy is limited principally by the realization of the present definition of the metre,

## • that wavelengths determined from frequency measurements and a given value for the  speed of light have a reproducibility superior to that which can be obtained by  comparison with the wavelength of the standard radiation of krypton 86,

## • that there is an advantage, notably for astronomy and geodesy, in maintaining  unchanged the value of the speed of light recommended in 1975 by the 15th CGPM in  its Resolution 2 (c = 299 792 458 m/s),

## • that a new definition of the metre has been envisaged in various forms all of which have  the effect of giving the speed of light an exact value, equal to the recommended value,  and that this introduces no appreciable discontinuity into the unit of length, taking into  account the relative uncertainty of ± 4 × 10−9 of the best realizations of the present  definition of the metre,

## • that these various forms, making reference either to the path travelled by light in a specified  time interval or to the wavelength of a radiation of measured or specified frequency, have  been the object of consultations and deep discussions, have been recognized as being  equivalent and that a consensus has emerged in favour of the first form,

## • that the Comité Consultatif pour la Définition du Mètre (CCDM) is now in a position to  give instructions for the practical realization of such a definition, instructions which could  include the use of the orange radiation of krypton 86 used as standard up to now, and  which may in due course be extended or revised,

decides

1\. The metre is the length of the path travelled by light in vacuum during a time interval of  1/299 792 458 of a second,

2\. The definition of the metre in force since 1960, based upon the transition between the levels  2p10 and 5d5 of the atom of krypton 86, is abrogated.

Note: The wording of the definition of the metre was modified by the 26th CGPM in 2018  (Resolution 1, see p. 194).

The relative uncertainty of the best realizations of the present definition of the metre given  here corresponds to three standard deviations in the data considered.

  On the realization of the definition of the metre (CR, 98 and Metrologia, 1984,  20, 25-26)

Resolution 2

The 17th Conférence Générale des Poids et Mesures,

invites the Comité International des Poids et Mesures

## • to draw up instructions for the practical realization of the new definition of the metre,

## • to choose radiations which can be recommended as standards of wavelength for the  interferometric measurement of length and to draw up instructions for their use,

## • to pursue studies undertaken to improve these standards.

Note: See Recommendation 1 (CI-2002) of the CIPM on the revision of the practical  realization of the definition of the metre, p. 177.

172  •  Appendix 1

### CIPM, 1984

  Concerning the sievert (PV, 52, 31 and Metrologia, 1985, 21, 90)

Recommendation 1

The Comité International des Poids et Mesures,

considering the confusion which continues to exist on the subject of Resolution 5, approved by  the 16th Conférence Générale des Poids et Mesures (1979),

decides to introduce the following explanation in the brochure “Le Système International d’Unités  (SI)”:

The quantity dose equivalent H is the product of the absorbed dose D of ionizing radiation and  the dimensionless factors Q (quality factor) and N (product of any other multiplying factors)  stipulated by the International Commission on Radiological Protection:

H = Q · N · D.

Thus, for a given radiation, the numerical value of H in joules per kilogram may differ from that of  D in joules per kilogram depending upon the values of Q and N. In order to avoid any risk of  confusion between the absorbed dose D and the dose equivalent H, the special names for the  respective units should be used, that is, the name gray should be used instead of joules per  kilogram for the unit of absorbed dose D and the name sievert instead of joules per kilogram for  the unit of dose equivalent H.

Note: The CIPM, in 2002, decided to change the explanation of the quantity dose  equivalent in the SI Brochure (Recommendation 2, see p. 179).

### 18th CGPM, 1987

  Forthcoming adjustment to the representations of the volt and of the ohm (CR,  100 and Metrologia, 1988, 25, 115)

Resolution 6

The 18th Conférence Générale des Poids et Mesures,

considering

## • that worldwide uniformity and long-term stability of national representations of the electrical  units are of major importance for science, commerce and industry from both the technical and  economic points of view,

## • that many national laboratories use the Josephson effect and are beginning to use the  quantum Hall effect to maintain, respectively, representations of the volt and of the ohm, as  these offer the best guarantees of long-term stability,

## • that because of the importance of coherence among the units of measurement of the various  physical quantities the values adopted for these representations must be as closely as  possible in agreement with the SI,

## • that the results of recent and current experiment will permit the establishment of an  acceptable value, sufficiently compatible with the SI, for the coefficient which relates each of  these effects to the corresponding electrical unit,

invites the laboratories whose work can contribute to the establishment of the quotient  voltage/frequency in the case of the Josephson effect and of the quotient voltage/current for the  quantum Hall effect to vigorously pursue these efforts and to communicate their results without  delay to the Comité International des Poids et Mesures, and

instructs the Comité International des Poids et Mesures to recommend, as soon as it considers  it possible, a value for each of these quotients together with a date for them to be put into  practice simultaneously in all countries; these values should be announced at least one year in  advance and would be adopted on 1 January 1990.

Appendix 1  •  173

### CIPM, 1988

  Representation of the volt by means of the Josephson effect (PV, 56, 44 and  Metrologia, 1989, 26, 69)

Recommendation 1

The Comité International des Poids et Mesures,

acting in accordance with instructions given in Resolution 6 of the 18th Conférence Générale  des Poids et Mesures concerning the forthcoming adjustment of the representations of the volt  and the ohm,

considering

## • that a detailed study of the results of the most recent determinations leads to a value of  483 597.9 GHz/V for the Josephson constant, KJ, that is to say, for the quotient of  frequency divided by the potential difference corresponding to the n = 1 step in the  Josephson effect,

## • that the Josephson effect, together with this value of KJ, can be used to establish a  reference standard of electromotive force having a one-standard-deviation uncertainty with  respect to the volt estimated to be 4 parts in 107, and a reproducibility which is significantly  better,

recommends

## • that 483 597.9 GHz/V exactly be adopted as a conventional value, denoted by KJ-90 for the  Josephson constant, KJ,

## • that this new value be used from 1 January 1990, and not before, to replace the values  currently in use,

## • that this new value be used from this same date by all laboratories which base their  measurements of electromotive force on the Josephson effect, and

## • that from this same date all other laboratories adjust the value of their laboratory reference  standards to agree with the new adopted value,

is of the opinion that no change in this recommended value of the Josephson constant will be  necessary in the foreseeable future, and

draws the attention of laboratories to the fact that the new value is greater by 3.9 GHz/V, or  about 8 parts in 106, than the value given in 1972 by the Comité Consultatif d'Électricité in its  Declaration E-72.

Note: The 26th CGPM in 2018 (Resolution 1, see p. 194) abrogated the adoption of a  conventional value for KJ.

  Representation of the ohm by means of the quantum Hall effect (PV, 56, 45 and  Metrologia, 1989, 26, 70)

Recommendation 2

The Comité International des Poids et Mesures,

acting in accordance with instructions given in Resolution 6 of the 18th Conférence Générale  des Poids et Mesures concerning the forthcoming adjustment of the representations of the volt  and the ohm,

considering

## • that most existing laboratory reference standards of resistance change significantly with  time,

## • that a laboratory reference standard of resistance based on the quantum Hall effect would  be stable and reproducible,

## • that a detailed study of the results of the most recent determinations leads to a value of  25 812.807 Ω for the von Klitzing constant, RK, that is to say, for the quotient of the Hall  potential difference divided by current corresponding to the plateau i = 1 in the quantum  Hall effect,

174  •  Appendix 1

## • that the quantum Hall effect, together with this value of RK, can be used to establish a  reference standard of resistance having a one-standard-deviation uncertainty with respect  to the ohm estimated to be 2 parts in 107, and a reproducibility which is significantly better,

recommends

## • that 25 812.807 Ω exactly be adopted as a conventional value, denoted by RK-90, for the  von Klitzing constant, RK,

## • that this value be used from 1 January 1990, and not before, by all laboratories which base  their measurements of resistance on the quantum Hall effect,

## • that from this same date all other laboratories adjust the value of their laboratory reference  standards to agree with RK-90,

## • that in the use of the quantum Hall effect to establish a laboratory reference standard of  resistance, laboratories follow the most recent edition of the technical guidelines for reliable  measurements of the quantized Hall resistance drawn up by the Comité Consultatif  d'Électricité and published by the Bureau International des Poids et Mesures, and

is of the opinion that no change in this recommended value of the von Klitzing constant will be  necessary in the foreseeable future.

Note: At its 89th meeting in 2000, the CIPM approved the declaration of the 22nd meeting  of the CCEM on the use of the value of the von Klitzing constant.

The 26th CGPM in 2018 (Resolution 1, see p. 194) abrogated the adoption of a  conventional value for RK.

### CIPM, 1989

  The International Temperature Scale of 1990 (PV, 57, 115 and Metrologia, 1990,  27, 13)

Recommendation 5

The Comité International des Poids et Mesures (CIPM) acting in accordance with Resolution 7 of  the 18th Conférence Générale des Poids et Mesures (1987) has adopted the International  Temperature Scale of 1990 (ITS-90) to supersede the International Practical Temperature Scale  of 1968 (IPTS-68).

The CIPM notes that, by comparison with the IPTS-68, the ITS-90

## • extends to lower temperatures, down to 0.65 K, and hence also supersedes the EPT-76,

## • is in substantially better agreement with corresponding thermodynamic temperatures,

## • has much improved continuity, precision and reproducibility throughout its range and

## • has subranges and alternative definitions in certain ranges which greatly facilitate its use.

The CIPM also notes that, to accompany the text of the ITS-90 there will be two further  documents, the Supplementary Information for the ITS-90 and Techniques for Approximating the  ITS-90. These documents will be published by the BIPM and periodically updated.

The CIPM recommends

## • that on 1 January 1990 the ITS-90 come into force and

## • that from this same date the IPTS-68 and the EPT-76 be abrogated.

Note: The kelvin was redefined by the 26th CGPM in 2018 (Resolution 1, see p. 194).

### 19th CGPM, 1991

  SI prefixes zetta, zepto, yotta and yocto (CR, 185 and Metrologia, 1992, 29, 3)

Resolution 4

The 19th Conférence Générale des Poids et Mesures (CGPM)

decides to add to the list of SI prefixes to be used for multiples and submultiples of units,  adopted by the 11th CGPM, Resolution 12, paragraph 3, the 12th CGPM, Resolution 8 and the  15th CGPM, Resolution 10, the following prefixes:

Appendix 1  •  175

Multiplying factor   Prefix Symbol

1021    zetta Z

10−21    zepto z

1024    yotta Y

10−24    yocto y

Note: The names zepto and zetta are derived from septo suggesting the number seven (the  seventh power of 103) and the letter “z” is substituted for the letter “s” to avoid the  duplicate use of the letter “s” as a symbol. The names yocto and yotta are derived from  octo, suggesting the number eight (the eighth power of 103); the letter “y” is added to avoid  the use of the letter “o” as a symbol because it may be confused with the number zero.

New prefixes were added by the 27th CGPM in 2022 (Resolution 3, see p. 196).

### 20th CGPM, 1995

  Elimination of the class of supplementary units in the SI (CR, 223 and  Metrologia, 1996, 33, 83)

Resolution 8

The 20th Conférence Générale des Poids et Mesures (CGPM),

considering

## • that the 11th Conférence Générale in 1960 in its Resolution 12, establishing the Système  International d’Unités, SI, distinguished between three classes of SI units: the base units,  the derived units, and the supplementary units, the last of these comprising the radian and  the steradian,

## • that the status of the supplementary units in relation to the base units and the derived units  gave rise to debate,

## • that the Comité International des Poids et Mesures, in 1980, having observed that the  ambiguous status of the supplementary units compromises the internal coherence of the SI,  has in its Recommendation 1 (CI-1980) interpreted the supplementary units, in the SI, as  dimensionless derived units,

approving the interpretation given by the Comité International in 1980,

decides

## • to interpret the supplementary units in the SI, namely the radian and the steradian, as  dimensionless derived units, the names and symbols of which may, but need not, be used  in expressions for other SI derived units, as is convenient,

## • and, consequently, to eliminate the class of supplementary units as a separate class in the SI.

### 21st CGPM, 1999

  The definition of the kilogram (CR, 331 and Metrologia, 2000, 37, 94)

Resolution 7

The 21st Conférence Générale des Poids et Mesures,

considering

## • the need to assure the long-term stability of the International System of Units (SI),

## • the intrinsic uncertainty in the long-term stability of the artefact defining the unit of mass,  one of the base units of the SI,

## • the consequent uncertainty in the long-term stability of the other three base units of the SI  that depend on the kilogram, namely, the ampere, the mole and the candela,

## • the progress already made in a number of different experiments designed to link the unit of  mass to fundamental or atomic constants,

## • the desirability of having more than one method of making such a link,

176  •  Appendix 1

recommends that national laboratories continue their efforts to refine experiments that link the  unit of mass to fundamental or atomic constants with a view to a future redefinition of the  kilogram.

  Special name for the SI derived unit mole per second, the katal, for the  expression of catalytic activity (CR, 334-335 and Metrologia, 2000, 37, 95)

Resolution 12

The 21st Conférence Générale des Poids et Mesures,

considering

## • the importance for human health and safety of facilitating the use of SI units in the fields of  medicine and biochemistry,

## • that a non-SI unit called “unit”, symbol U, equal to 1 µmol ∙ min–1, which is not coherent with  the International System of Units (SI), has been in widespread use in medicine and  biochemistry since 1964 for expressing catalytic activity,

## • that the absence of a special name for the SI coherent derived unit mole per second has led  to results of clinical measurements being given in various local units,

## • that the use of SI units in medicine and clinical chemistry is strongly recommended by the  international unions in these fields,

## • that the International Federation of Clinical Chemistry and Laboratory Medicine has asked  the Consultative Committee for Units to recommend the special name katal, symbol kat, for  the SI unit mole per second,

## • that while the proliferation of special names represents a danger for the SI, exceptions are  made in matters related to human health and safety (15th General Conference, 1975,  Resolutions 8 and 9, 16th General Conference, 1979, Resolution 5),

noting that the name katal, symbol kat, has been used for the SI unit mole per second for over  thirty years to express catalytic activity,

decides to adopt the special name katal, symbol kat, for the SI unit mole per second to express  catalytic activity, especially in the fields of medicine and biochemistry,

and recommends that when the katal is used, the measurand be specified by reference to the  measurement procedure; the measurement procedure must identify the indicator reaction.

### CIPM, 2001

   “SI units” and “units of the SI” (PV, 69, 120)

The CIPM approved in 2001 the following proposal of the CCU regarding “SI units” and  “units of the SI”:

“We suggest that “SI units” and “units of the SI” should be regarded as names that include both  the base units and the coherent derived units, and also all units obtained by combining these  with the recommended multiple and sub-multiple prefixes.

We suggest that the name “coherent SI units” should be used when it is desired to restrict the  meaning to only the base units and the coherent derived units.”

### CIPM, 2002

  Revision of the practical realization of the definition of the metre (PV, 70,  194-204 and Metrologia, 40, 103-133)

Recommendation 1

The International Committee for Weights and Measures,

recalling

## • that in 1983 the 17th General Conference (CGPM) adopted a new definition of the metre;

## • that in the same year the CGPM invited the International Committee (CIPM)

## • to draw up instructions for the practical realization of the metre,

Appendix 1  •  177

## • to choose radiations which can be recommended as standards of wavelength for the  interferometric measurement of length and draw up instructions for their use,

## • to pursue studies undertaken to improve these standards and in due course to extend or  revise these instructions;

## • that in response to this invitation the CIPM adopted Recommendation 1 (CI-1983) (mise en  pratique of the definition of the metre) to the effect

## • that the metre should be realized by one of the following methods:

(a) by means of the length l of the path travelled in vacuum by a plane electromagnetic  wave in a time t; this length is obtained from the measured time t, using the relation  l = c0 · t and the value of the speed of light in vacuum c0 = 299 792 458 m/s,

(b) by means of the wavelength in vacuum λ of a plane electromagnetic wave of  frequency f; this wavelength is obtained from the measured frequency f using the  relation λ = c0 / f and the value of the speed of light in vacuum c0 = 299 792 458 m/s,

(c) by means of one of the radiations from the list below, whose stated wavelength in  vacuum or whose stated frequency can be used with the uncertainty shown, provided  that the given specifications and accepted good practice are followed;

## • that in all cases any necessary corrections be applied to take account of actual conditions  such as diffraction, gravitation or imperfection in the vacuum;

## • that in the context of general relativity, the metre is considered a unit of proper length. Its  definition, therefore, applies only within a spatial extent sufficiently small that the effects of the  non-uniformity of the gravitational field can be ignored (note that, at the surface of the Earth,  this effect in the vertical direction is about 1 part in 1016 per metre). In this case, the effects to  be taken into account are those of special relativity only. The local methods for the realization  of the metre recommended in (b) and (c) provide the proper metre but not necessarily that  given in (a). Method (a) should therefore be restricted to lengths l which are sufficiently short  for the effects predicted by general relativity to be negligible with respect to the uncertainties  of realization. For advice on the interpretation of measurements in which this is not the case,  see the report of the Consultative Committee for Time and Frequency (CCTF) Working Group  on the Application of General Relativity to Metrology (Application of general relativity to  metrology, Metrologia, 1997, 34, 261-290);

## • that the CIPM had already recommended a list of radiations for this purpose;

recalling also that in 1992 and in 1997 the CIPM revised the practical realization of the definition  of the metre;

considering

## • that science and technology continue to demand improved accuracy in the realization of the  metre;

## • that since 1997 work in national laboratories, in the BIPM and elsewhere has identified new  radiations and methods for their realization which lead to lower uncertainties;

## • that there is an increasing move towards optical frequencies for time-related activities, and  that there continues to be a general widening of the scope of application of the recommended  radiations of the mise en pratique to cover not only dimensional metrology and the realization  of the metre, but also high-resolution spectroscopy, atomic and molecular physics,  fundamental constants and telecommunication;

## • that a number of new frequency values with reduced uncertainties for radiations of high- stability cold atom and ion standards already listed in the recommended radiations list are  now available, that the frequencies of radiations of several new cold atom and ion species  have also recently been measured, and that new improved values with substantially reduced  uncertainties for a number of optical frequency standards based on gas cells have been  determined, including the wavelength region of interest to optical telecommunications;

## • that new femtosecond comb techniques have clear significance for relating the frequency of  high-stability optical frequency standards to that of the frequency standard realizing the SI  second, that these techniques represent a convenient measurement technique for providing  traceability to the International System of Units (SI) and that comb technology also can  provide frequency sources as well as a measurement technique;

178  •  Appendix 1

recognizes comb techniques as timely and appropriate, and recommends further research to  fully investigate the capability of the techniques;

welcomes validations now being made of comb techniques by comparison with other frequency  chain techniques;

urges national metrology institutes and other laboratories to pursue the comb technique to the  highest level of accuracy achievable and also to seek simplicity so as to encourage widespread  application;

recommends

## • that the list of recommended radiations given by the CIPM in 1997 (Recommendation 1  (CI-1997)) be replaced by the list of radiations given below, including

## • updated frequency values for cold Ca atom, H atom and the trapped Sr+ ion,

## • frequency values for new cold ion species including trapped Hg+ ion, trapped In+ ion and  trapped Yb+ ion,

## • updated frequency values for Rb-stabilized lasers, I2-stabilized Nd:YAG and He-Ne lasers,  CH4-stabilized He-Ne lasers and OsO4-stabilized CO2 lasers at 10 µm,

## • frequency values for standards relevant to the optical communications bands, including Rb-  and C2H2-stabilized lasers.

. . .

Note: The list of recommended radiations, Recommendation 1 (CI-2002), is given in PV,  70, 197-204 and Metrologia, 2003, 40, 104-115.

  Dose equivalent (PV, 70, 205)

Recommendation 2

The International Committee for Weights and Measures,

considering that

## • the current definition of the SI unit of dose equivalent (sievert) includes a factor “N ” (product  of any other multiplying factors) stipulated by the International Commission on Radiological  Protection (ICRP), and

## • both the ICRP and the International Commission on Radiation Units and Measurements  (ICRU) have decided to delete this factor N as it is no longer deemed to be necessary, and

## • the current SI definition of H including the factor N is causing some confusion,

decides to change the explanation in the brochure “Le Système International d’Unités (SI)” to the  following:

The quantity dose equivalent H is the product of the absorbed dose D of ionizing radiation and  the dimensionless factor Q (quality factor) defined as a function of linear energy transfer by the  ICRU:

H = Q · D.

Thus, for a given radiation, the numerical value of H in joules per kilogram may differ from that of  D in joules per kilogram depending on the value of Q.

The Committee further decides to maintain the final sentence in the explanation as follows:

In order to avoid any risk of confusion between the absorbed dose D and the dose equivalent H,  the special names for the respective units should be used, that is, the name gray should be used  instead of joules per kilogram for the unit of absorbed dose D and the name sievert instead of  joules per kilogram for the unit of dose equivalent H.

Note: See also J. Radiol. Prot., 2005, 25, 97-100.

Appendix 1  •  179

### CIPM, 2003

  Revision of the Mise en Pratique list of recommended radiations (PV, 71, 146  and Metrologia, 2004, 41, 99-100)

Recommendation 1

The International Committee for Weights and Measures,

considering that

## • improved frequency values for radiations of some high-stability cold ion standards already  documented in the recommended radiations list have recently become available;

## • improved frequency values for the infra-red gas-cell-based optical frequency standard in the  optical telecommunications region, already documented in the recommended radiations list,  have been determined;

## • femtosecond comb-based frequency measurements for certain iodine gas-cell standards on  the subsidiary recommended source list have recently been made for the first time, leading to  significantly reduced uncertainty;

proposes that the recommended radiation list be revised to include the following:

## • updated frequency values for the single trapped 88Sr+ ion quadrupole transition and the single  trapped 171Yb+ octupole transition;

## • an updated frequency value for the C2H2-stabilized standard at 1.54 µm;

## • updated frequency values for the I2-stabilized standards at 543 nm and 515 nm.

### 22nd CGPM, 2003

  Symbol for the decimal marker (CR, 381 and Metrologia, 2004, 41, 104)

Resolution 10

The 22nd General Conference,

considering that

## • a principal purpose of the International System of Units (SI) is to enable values of quantities  to be expressed in a manner that can be readily understood throughout the world,

## • the value of a quantity is normally expressed as a number times a unit,

## • often the number in the expression of the value of a quantity contains multiple digits with an  integral part and a decimal part,

## • in Resolution 7 of the 9th General Conference, 1948, it is stated that “In numbers, the comma  (French practice) or the dot (British practice) is used only to separate the integral part of  numbers from the decimal part”,

## • following a decision of the International Committee made at its 86th meeting (1997), the  International Bureau of Weights and Measures now uses the dot (point on the line) as the  decimal marker in all the English language versions of its publications, including the English  text of the SI Brochure (the definitive international reference on the SI), with the comma (on  the line) remaining the decimal marker in all of its French language publications,

## • however, some international bodies use the comma on the line as the decimal marker in their  English language documents,

## • furthermore, some international bodies, including some international standards organizations,  specify the decimal marker to be the comma on the line in all languages,

## • the prescription of the comma on the line as the decimal marker is in many languages in  conflict with the customary usage of the point on the line as the decimal marker in those  languages,

## • in some languages that are native to more than one country, either the point on the line or the  comma on the line is used as the decimal marker depending on the country, while in some  countries with more than one native language, either the point on the line or comma on the  line is used depending on the language,

declares that the symbol for the decimal marker shall be either the point on the line or the  comma on the line,

reaffirms that “Numbers may be divided in groups of three in order to facilitate reading; neither  dots nor commas are ever inserted in the spaces between groups”, as stated in Resolution 7 of  the 9th CGPM, 1948.

180  •  Appendix 1

### CIPM, 2005

  Clarification of the definition of the kelvin, unit of thermodynamic temperature  (PV, 73, 235 and Metrologia, 2006, 43, 177-178)

Recommendation 2

The International Committee for Weights and Measures (CIPM),

considering

## • that the kelvin, unit of thermodynamic temperature, is defined as the fraction 1/273.16 of the  thermodynamic temperature of the triple point of water,

## • that the temperature of the triple point depends on the relative amount of isotopes of  hydrogen and oxygen present in the sample of water used,

## • that this effect is now one of the major sources of the observed variability between different  realizations of the water triple point,

decides

## • that the definition of the kelvin refer to water of a specified isotopic composition,

## • that this composition be:

0\.000 155 76 mole of 2H per mole of 1H,

0\.000 379 9 mole of 17O per mole of 16O, and

0\.002 005 2 mole of 18O per mole of 16O,

which is the composition of the International Atomic Energy Agency reference material Vienna  Standard Mean Ocean Water (VSMOW), as recommended by IUPAC in “Atomic Weights of the  Elements: Review 2000”.

## • that this composition be stated in a note attached to the definition of the kelvin in the SI  brochure as follows:

“This definition refers to water having the isotopic composition defined exactly by the  following amount of substance ratios: 0.000 155 76 mole of 2H per mole of 1H,  0.000 379 9 mole of 17O per mole of 16O and 0.002 005 2 mole of 18O per mole of 16O”.

Note: The kelvin was redefined by the 26th CGPM in 2018 (Resolution 1, see p. 194).

  Revision of the Mise en pratique list of recommended radiations (PV, 73, 236  and Metrologia, 2006, 43, 178)

Recommendation 3

The International Committee for Weights and Measures (CIPM),

considering that:

## • improved frequency values for radiations of some high-stability cold ion and cold atom  standards already documented in the recommended radiations list have recently become  available;

## • improved frequency values for the infra-red gas-cell-based optical frequency standard in the  optical telecommunications region, already documented in the recommended radiations list,  have been determined;

## • improved frequency values for certain iodine gas-cell standard, already documented in the  subsidiary recommended source list, have been determined;

## • frequencies of new cold atoms, of atoms in the near-infrared region and of molecules in the  optical telecommunications region have been determined by femtosecond comb-based  frequency measurements for the first time;

decides that the list of recommended radiations be revised to include the following:

## • updated frequency values for the single trapped 88Sr+ ion quadrupole transition, the single  trapped 199Hg+ quadrupole transition and the single trapped 171Yb+ quadrupole transition;

## • an updated frequency value for the Ca atom transition;

Appendix 1  •  181

## • an updated frequency value for the C2H2-stabilized standard at 1.54 µm;

## • an updated frequency value for the I2-stabilized standard at 515 nm;

## • the addition of the 87Sr atom transition at 698 nm;

## • the addition of the 87Rb atom two-photon transitions at 760 nm;

## • the addition of the 12C2H2 (ν1 + ν3) band and the 13C2H2 (ν1 + ν3) and (ν1 + ν3 + ν4 + ν5)  bands at 1.54 µm.

### CIPM, 2006

  Concerning secondary representations of the second (PV, 74, 249 and  Metrologia, 2007, 44, 97)

Recommendation 1

The International Committee for Weights and Measures (CIPM),

considering that

- • a common list of “Recommended values of standard frequencies for applications including  the practical realization of the metre and secondary representations of the second” shall be  established,
- • the CCL/CCTF Joint Working Group (JWG) on the Mise en Pratique of the Definition of the  Metre and the Secondary Representations of the Second in its meeting at the International  Bureau of Weights and Measures (BIPM) in September 2005 discussed possible candidates  to be included in this list for secondary representations of the second,
- • the CCL/CCTF JWG reviewed and updated the values for the Hg ion, Sr ion, Yb ion, and the  Sr neutral atom transition frequencies in its session in September 2006,
- • the CCTF in its Recommendation CCTF 1 (2004) already recommended the unperturbed  ground-state hyperfine quantum transition frequency of 87Rb as a secondary representation  of the second;

recommends that the following transition frequencies shall be used as secondary  representations of the second and be included into the new list of “Recommended values of  standard frequencies for applications including the practical realization of the metre and  secondary representations of the second”

- • the unperturbed ground-state hyperfine quantum transition of 87Rb with a frequency of  f87Rb = 6 834 682 610.904 324 Hz and an estimated relative standard uncertainty of  3 × 10−15,
- • the unperturbed optical 5s 2S1/2 – 4d 2D5/2 transition of the 88Sr+ ion with a frequency of  f88Sr+ = 444 779 044 095 484 Hz and a relative uncertainty of 7 × 10−15,
- • the unperturbed optical 5d10 6s 2S1/2 (F = 0) – 5d9 6s2 2D5/2 (F = 2) transition of the 199Hg+  ion with a frequency of f199Hg+ = 1 064 721 609 899 145 Hz and a relative standard  uncertainty of 3 × 10−15,
- • the unperturbed optical 6s 2S1/2 (F = 0) – 5d 2D3/2 (F = 2) transition of the 171Yb+ ion with a  frequency of f171Yb+ = 688 358 979 309 308 Hz and a relative standard uncertainty of  9 × 10−15,
- • the unperturbed optical transition 5s2 1S0 – 5s 5p 3P0 of the 87Sr neutral atom with a  frequency of f87Sr = 429 228 004 229 877 Hz and a relative standard uncertainty of  1.5 × 10−14.

182  •  Appendix 1

### CIPM, 2007

  Revision of the Mise en pratique list of recommended radiations (PV, 75, 185)

Recommendation 1

The International Committee for Weights and Measures,

considering that:

- • improved frequency values of molecules in the optical telecommunications region, already  documented in the list of standard frequencies, have been determined by femtosecond  comb-based frequency measurements;
- • frequencies of molecules in the optical telecommunications region have been determined  by femtosecond comb-based frequency measurements for the first time;
- • frequencies of certain iodine gas-cell absorptions close to the 532 nm optical frequency  standard have been determined by femtosecond comb-based frequency measurements for  the first time;

proposes that the list of standard frequencies be revised to include the following:

- • an updated list of frequency values for the 12C2H2 (ν1 + ν3) band at 1.54 µm;
- • the addition of frequency values for the 12C2HD (2ν1) band at 1.54 µm;
- • the addition of frequency values for the hyperfine components of the P(142) 37-0, R(121)  35-0 and R(85) 33-0 iodine transitions at 532 nm.

### 23rd CGPM, 2007

  On the revision of the mise en pratique of the definition of the metre and the  development of new optical frequency standards (CR, 431)

Resolution 9

The 23rd General Conference,

considering that:

- • there have been rapid and important improvements in the performance of optical frequency  standards,
- • femtosecond comb techniques are now used routinely for relating optical and microwave  radiations at a single location,
- • National Metrology Institutes (NMIs) are working on comparison techniques for optical  frequency standards over short distances,
- • remote comparison techniques need to be developed at an international level so that optical  frequency standards can be compared,

welcomes

- • the activities of the Joint Working Group of the Consultative Committee for Length and the  Consultative Committee for Time and Frequency to review the frequencies of optically- based representations of the second,
- • the additions to the mise en pratique of the definition of the metre and to the list of  recommended radiations made by the International Committee in 2002, 2003, 2005, 2006,  and 2007,
- • the initiative taken by the International Bureau of Weights and Measures (BIPM) to raise the  issue of how to compare optical frequency standards,

recommends that:

- • NMIs commit resources to the development of optical frequency standards and their  comparison,
- • the BIPM works toward the coordination of an international project with the participation of  NMIs, oriented to the study of the techniques which could serve to compare optical  frequency standards.

Appendix 1  •  183

  Clarification of the definition of the kelvin, unit of thermodynamic temperature  (CR, 432)

Resolution 10

The 23rd General Conference,

considering

- • that the kelvin, unit of thermodynamic temperature, is defined as the fraction 1/273.16 of the  thermodynamic temperature of the triple point of water,
- • that the temperature of the triple point depends on the relative amount of isotopes of  hydrogen and oxygen present in the sample of water used,
- • that this effect is now one of the major sources of the observed variability between different  realizations of the water triple point,

notes and welcomes the decision by the International Committee for Weights and Measures in  October 2005, on the advice of the Consultative Committee for Thermometry, that

- • the definition of the kelvin refers to water of a specified isotopic composition,
- • this composition be:

0\.000 155 76 mole of 2H per mole of 1H,

0\.000 379 9 mole of 17O per mole of 16O, and

0\.002 005 2 mole of 18O per mole of 16O,

which is the composition of the International Atomic Energy Agency reference material Vienna  Standard Mean Ocean Water (VSMOW), as recommended by the International Union of Pure  and Applied Chemistry in "Atomic Weights of the Elements: Review 2000",

- • this composition be stated in a note attached to the definition of the kelvin in the SI  Brochure as follows:

"This definition refers to water having the isotopic composition defined by the following  amount-of-substance ratios: 0.000 155 76 mole of 2H per mole of 1H, 0.000 379 9 mole  of 17O per mole of 16O and 0.002 005 2 mole of 18O per mole of 16O".

Note: The kelvin was redefined by the 26th CGPM in 2018 (Resolution 1, see p. 194).

  On the possible redefinition of certain base units of the International System  of Units (SI) (CR, 434)

Resolution 12

The 23rd General Conference,

considering

- • that, for many years, National Metrology Institutes (NMIs) as well as the International  Bureau of Weights and Measures (BIPM) have made considerable efforts to advance and  improve the International System of Units (SI) by extending the frontiers of metrology so  that the SI base units could be defined in terms of the invariants of nature - the fundamental  physical constants,
- • that, of the seven base units of the SI, only the kilogram is still defined in terms of a material  artefact - the international prototype of the kilogram (2nd CGPM, 1889, 3rd CGPM, 1901)  and that the definitions of the ampere, mole and candela depend on the kilogram,
- • Resolution 7 of the 21st General Conference (1999) which recommended that "national  laboratories continue their efforts to refine experiments that link the unit of mass to  fundamental or atomic constants with a view to a future redefinition of the kilogram",
- • the many advances, made in recent years, in experiments which relate the mass of the  international prototype to the Planck constant h or the Avogadro constant NA,
- • initiatives to determine the value of a number of relevant fundamental constants, including  work to redetermine the Boltzmann constant kB,

184  •  Appendix 1

- • that as a result of recent advances, there are significant implications for, and potential  benefits from, redefinitions of the kilogram, the ampere, the kelvin and the mole,
- • Recommendation 1 of the International Committee (C1-2005) at its meeting in October  2005, and various Recommendations of Consultative Committees on the subject of a  redefinition of one or more of the base units of the SI,

noting

- • that any changes in definitions of units of the SI must be constrained by self-consistency,
- • that it is desirable that definitions of the base units should be easily understood,
- • the work of the International Committee and the Consultative Committees,
- • the need to monitor the results of relevant experiments,
- • the importance of soliciting comments and contributions from the wider scientific and user  communities, and
- • the decision of the International Committee in 2005 to approve, in principle, the preparation  of new definitions of the kilogram, ampere, kelvin and the possibility of redefining the mole,

recommends that National Metrology Institutes and the BIPM

- • pursue the relevant experiments so that the International Committee can come to a view on  whether it may be possible to redefine the kilogram, the ampere, the kelvin, and the mole  using fixed values of the fundamental constants at the time of the 24th General Conference  (2011),
- • should, together with the International Committee, its Consultative Committees, and  appropriate working groups, work on practical ways of realizing any new definitions based  on fixed values of the fundamental constants, prepare a mise en pratique for each of them,  and consider the most appropriate way of explaining the new definitions to users,
- • initiate awareness campaigns to alert user communities to the possibility of redefinitions  and that the technical and legislative implications of such redefinitions and their practical  realizations be carefully discussed and considered,

and requests the International Committee to report on these issues to the 24th General  Conference in 2011 and to undertake whatever preparations are considered necessary so that, if  the results of experiments are found to be satisfactory and the needs of users met, formal  proposals for changes in the definitions of the kilogram, ampere, the kelvin and mole can be put  to the 24th General Conference.

Note: The 26th CGPM in 2018 (Resolution 1, see p. 194) finally approved the revision of  the SI.

### CIPM, 2009

  Updates to the list of standard frequencies (PV, 77, 235)

Recommendation 2

The International Committee for Weights and Measures (CIPM),

considering that

- - • a common list of “Recommended values of standard frequencies for applications including  the practical realization of the metre and secondary representations of the second” has been  established;
  - • the CCL-CCTF Frequency Standards Working Group (FSWG) has reviewed several  promising candidates for inclusion in the list;

recommends

that the following transition frequencies shall be included or updated in the list of recommended  standard frequencies:

- - • the unperturbed optical transition 5s2 1S0 – 5s 5p 3P0 of the 87Sr neutral atom with a frequency  of f = 429 228 004 229 873.7 Hz and a relative standard uncertainty of 1 × 10−15 (this  radiation is already endorsed by the CIPM as a secondary representation of the second);

Appendix 1  •  185

- - • the unperturbed optical transition 5s2 1S0 – 5s 5p 3P0 of the 88Sr neutral atom with a frequency  of f = 429 228 066 418 012 Hz and a relative standard uncertainty of 1 × 10−14;
  - • the unperturbed optical transition 4s 2S1/2 – 3d 2D5/2 of the 40Ca+ ion with a frequency of  f = 411 042 129 776 393 Hz and a relative standard uncertainty of 4 × 10−14;
  - • the unperturbed optical transition 2S1/2 (F = 0) – 2F7/2 (F = 3, mF = 0) of the 171Yb+ ion with a  frequency of f = 642 121 496 772 657 Hz and a relative standard uncertainty of 6 × 10−14;
  - •  the unperturbed optical transition 6s2 1S0 (F = 1/2) – 6s 6p 3P0 (F = 1/2) of the 171Yb neutral  atom with a frequency of f = 518 295 836 590 864 Hz and a relative standard uncertainty of  1.6 × 10−13.

### 24th CGPM, 2011

  On the possible future revision of the International System of Units, the SI  (CR, 532)

Resolution 1

The General Conference on Weights and Measures (CGPM), at its 24th meeting,

considering

- • the international consensus on the importance, value, and potential benefits of a redefinition  of a number of units of the International System of Units (SI),
- • that the national metrology institutes (NMIs) as well as the International Bureau of Weights  and Measures (BIPM) have rightfully expended significant effort during the last several  decades to advance the International System of Units (SI) by extending the frontiers of  metrology so that SI base units can be defined in terms of the invariants of nature - the  fundamental physical constants or properties of atoms,
- • that a prominent example of the success of such efforts is the current definition of the SI  unit of length, the metre (17th meeting of the CGPM, 1983, Resolution 1), which links it to  an exact value of the speed of light in vacuum c, namely, 299 792 458 metre per second,
- • that of the seven base units of the SI, only the kilogram is still defined in terms of a material  artefact, namely, the international prototype of the kilogram (1st meeting of the CGPM,  1889, 3rd meeting of the CGPM, 1901), and that the definitions of the ampere, mole and  candela depend on the kilogram,
- • that although the international prototype has served science and technology well since it  was sanctioned by the CGPM at its 1st meeting in 1889, it has a number of important  limitations, one of the most significant being that its mass is not explicitly linked to an  invariant of nature and in consequence its long-term stability is not assured,
- • that the CGPM at its 21st meeting in 1999 adopted Resolution 7 in which it recommended  that "national laboratories continue their efforts to refine experiments that link the unit of  mass to fundamental or atomic constants with a view to a future redefinition of the  kilogram",
- • that many advances have been made in recent years in relating the mass of the  international prototype to the Planck constant h, by methods which include watt balances  and measurements of the mass of a silicon atom,
- • that the uncertainties of all SI electrical units realized directly or indirectly by means of the  Josephson and quantum Hall effects together with the SI values of the Josephson and von  Klitzing constants KJ and RK could be significantly reduced if the kilogram were redefined so  as to be linked to an exact numerical value of h, and if the ampere were to be redefined so  as to be linked to an exact numerical value of the elementary charge e,
- • that the kelvin is currently defined in terms of an intrinsic property of water that, while being  an invariant of nature, in practice depends on the purity and isotopic composition of the  water used,
- • that it is possible to redefine the kelvin so that it is linked to an exact numerical value of the  Boltzmann constant k,
- • that it is also possible to redefine the mole so that it is linked to an exact numerical value of  the Avogadro constant NA, and is thus no longer dependent on the definition of the kilogram

186  •  Appendix 1

- even when the kilogram is defined so that it is linked to an exact numerical value of h,  thereby emphasizing the distinction between amount of substance and mass,
- • that the uncertainties of the values of many other important fundamental constants and  energy conversion factors would be eliminated or greatly reduced if h, e, k and NA had  exact numerical values when expressed in SI units,
- • that the General Conference, at its 23rd meeting in 2007, adopted Resolution 12 in which it  outlined the work that should be carried out by the NMIs, the BIPM and the International  Committee for Weights and Measures (CIPM) together with its Consultative Committees  (CCs) so that new definitions of the kilogram, ampere, kelvin, and mole in terms of  fundamental constants could be adopted,
- • that, although this work has progressed well, not all the requirements set out in  Resolution 12 adopted by the General Conference at its 23rd meeting in 2007 have been  satisfied and so the International Committee for Weights and Measures is not yet ready to  make a final proposal,
- • that, nevertheless, a clear and detailed explanation of what is likely to be proposed can now  be presented,

takes note of the intention of the International Committee for Weights and Measures to propose  a revision of the SI as follows:

- • the International System of Units, the SI, will be the system of units in which:
- • the ground state hyperfine splitting frequency of the caesium 133 atom Δν(133Cs)hfs  is exactly 9 192 631 770 hertz,
- • the speed of light in vacuum c is exactly 299 792 458 metre per second,
- • the Planck constant h is exactly 6.626 06X × 10−34 joule second,
- • the elementary charge e is exactly 1.602 17X × 10−19 coulomb,
- • the Boltzmann constant k is exactly 1.380 6X × 10−23 joule per kelvin,
- • the Avogadro constant NA is exactly 6.022 14X × 1023 reciprocal mole,
- • the luminous efficacy Kcd of monochromatic radiation of frequency 540 × 1012 Hz is  exactly 683 lumen per watt,

where

(i) the hertz, joule, coulomb, lumen, and watt, with unit symbols Hz, J, C, lm, and W,  respectively, are related to the units second, metre, kilogram, ampere, kelvin, mole,  and candela, with unit symbols s, m, kg, A, K, mol, and cd, respectively, according to  Hz = s−1, J = m2 kg s−2, C = s A, lm = cd m2 m−2 = cd sr, and W = m2 kg s−3,

(ii) the symbol X in this Draft Resolution represents one or more additional digits to be  added to the numerical values of h, e, k, and NA, using values based on the most  recent CODATA adjustment,

from which it follows that the SI will continue to have the present set of seven base units, in  particular

- • the kilogram will continue to be the unit of mass, but its magnitude will be set by  fixing the numerical value of the Planck constant to be equal to exactly  6.626 06X × 10−34 when it is expressed in the SI unit m2 kg s−1, which is equal to J s,
- • the ampere will continue to be the unit of electric current, but its magnitude will be  set by fixing the numerical value of the elementary charge to be equal to exactly  1.602 17X × 10−19 when it is expressed in the SI unit s A, which is equal to C,
- • the kelvin will continue to be the unit of thermodynamic temperature, but its  magnitude will be set by fixing the numerical value of the Boltzmann constant to be  equal to exactly 1.380 6X × 10−23 when it is expressed in the SI unit m2 kg s−2 K−1,  which is equal to J K−1,

the mole will continue to be the unit of amount of substance of a specified  elementary entity, which may be an atom, molecule, ion, electron, any other particle  or a specified group of such particles, but its magnitude will be set by fixing the

Appendix 1  •  187

numerical value of the Avogadro constant to be equal to exactly 6.022 14X

The General Conference on Weights and Measures

further notes that since

- • the new definitions of the kilogram, ampere, kelvin and mole are intended to be of the explicit- constant type, that is, a definition in which the unit is defined indirectly by specifying explicitly  an exact value for a well-recognized fundamental constant,
- • the existing definition of the metre is linked to an exact value of the speed of light in vacuum,  which is also a well-recognized fundamental constant,
- • the existing definition of the second is linked to an exact value of a well-defined property of  the caesium atom, which is also an invariant of nature,
- • although the existing definition of the candela is not linked to a fundamental constant, it may  be viewed as being linked to an exact value of an invariant of nature,
- • it would enhance the understandability of the International System if all of its base units were  of similar wording,

the International Committee for Weights and Measures will also propose

the reformulation of the existing definitions of the second, metre and candela in completely  equivalent forms, which might be the following:

- • the second, symbol s, is the unit of time; its magnitude is set by fixing the numerical value of  the ground state hyperfine splitting frequency of the caesium 133 atom, at rest and at a  temperature of 0 K, to be equal to exactly 9 192 631 770 when it is expressed in the SI unit  s−1, which is equal to Hz,
- • the metre, symbol m, is the unit of length; its magnitude is set by fixing the numerical value of  the speed of light in vacuum to be equal to exactly 299 792 458 when it is expressed in the SI  unit m s−1,
- • the candela, symbol cd, is the unit of luminous intensity in a given direction; its magnitude is  set by fixing the numerical value of the luminous efficacy of monochromatic radiation of  frequency 540 × 1012 Hz to be equal to exactly 683 when it is expressed in the SI unit  m−2  kg−1  s3  cd sr, or cd sr W−1, which is equal to lm W−1.

In this way, the definitions of all seven base units will be seen to follow naturally from the set of  seven constants given above.

In consequence, on the date chosen for the implementation of the revision of the SI:

- • the definition of the kilogram in force since 1889 based upon the mass of the international  prototype of the kilogram (1st meeting of the CGPM, 1889, 3rd meeting of the CGPM, 1901)  will be abrogated,
- • the definition of the ampere in force since 1948 (9th meeting of the CGPM, 1948) based upon  the definition proposed by the International Committee (CIPM, 1946, Resolution 2) will be  abrogated,
- • the conventional values of the Josephson constant KJ-90 and of the von Klitzing constant RK-90  adopted by the International Committee (CIPM, 1988, Recommendations 1 and 2) at the  request of the General Conference (18th meeting of the CGPM, 1987, Resolution 6) for the  establishment of representations of the volt and the ohm using the Josephson and quantum  Hall effects, respectively, will be abrogated,
- • the definition of the kelvin in force since 1967/68 (13th meeting of the CGPM, 1967/68,  Resolution 4) based upon a less explicit, earlier definition (10th meeting of the CGPM, 1954,  Resolution 3) will be abrogated,
- • the definition of the mole in force since 1971 (14th meeting of the CGPM, 1971, Resolution 3)  based upon a definition whereby the molar mass of carbon 12 had the exact value 0.012 kg  mol-1 will be abrogated,

the existing definitions of the metre, second and candela in force since they were adopted by  the CGPM at its 17th (1983, Resolution 1), 13th (1967/68, Resolution 1) and 16th (1979,  Resolution 3) meetings, respectively, will be abrogated.

× 1023  when it is expressed in the SI unit mol−1.

188  •  Appendix 1

The General Conference on Weights and Measures

further notes that on the same date

- • the mass of the international prototype of the kilogram m(K) will be 1 kg but with a relative  uncertainty equal to that of the recommended value of h just before redefinition and that  subsequently its value will be determined experimentally,
- • that the magnetic constant (permeability of vacuum) µ0 will be 4π × 10−7 H m−1 but with a  relative uncertainty equal to that of the recommended value of the fine-structure  constant α and that subsequently its value will be determined experimentally,
- • that the thermodynamic temperature of the triple point of water TTPW will be 273.16 K but with  a relative uncertainty equal to that of the recommended value of k just before redefinition and  that subsequently its value will be determined experimentally,
- • that the molar mass of carbon 12 M(12C) will be 0.012 kg mol−1 but with a relative uncertainty  equal to that of the recommended value of NAh just before redefinition and that subsequently  its value will be determined experimentally.

The General Conference on Weights and Measures

encourages

- • researchers in national metrology institutes, the BIPM and academic institutions to continue  their efforts and make known to the scientific community in general and to CODATA in  particular, the outcome of their work relevant to the determination of the constants h, e, k, and  NA, and
- • the BIPM to continue its work on relating the traceability of the prototypes it maintains to the  international prototype of the kilogram, and in developing a pool of reference standards to  facilitate the dissemination of the unit of mass when redefined,

invites

- • CODATA to continue to provide adjusted values of the fundamental physical constants based  on all relevant information available and to make the results known to the International  Committee through its Consultative Committee for Units since these CODATA values and  uncertainties will be those used for the revised SI,
- • the CIPM to make a proposal for the revision of the SI as soon as the recommendations of  Resolution 12 of the 23rd meeting of the General Conference are fulfilled, in particular the  preparation of mises en pratique for the new definitions of the kilogram, ampere, kelvin and  mole,
- • the CIPM to continue its work towards improved formulations for the definitions of the SI base  units in terms of fundamental constants, having as far as possible a more easily  understandable description for users in general, consistent with scientific rigour and clarity,
- • the CIPM, the Consultative Committees, the BIPM, the OIML and National Metrology  Institutes significantly to increase their efforts to initiate awareness campaigns aimed at  alerting user communities and the general public to the intention to redefine various units of  the SI and to encourage consideration of the practical, technical, and legislative implications  of such redefinitions, so that comments and contributions can be solicited from the wider  scientific and user communities.

Note: The 26th CGPM in 2018 (Resolution 1, see p. 194) finally approved the revision of  the SI.

The X digit appearing in the expression of the constants indicates that this digit was  unknown at the time of the resolution.

Appendix 1  •  189

  On the revision of the mise en pratique of the metre and the development of  new optical frequency standards (CR, 546)

Resolution 8

The General Conference on Weight and Measures (CGPM), at its 24th meeting,

considering that

- • there have been rapid and important improvements in the performance of optical frequency  standards,
- • national metrology institutes are working on comparison techniques for optical frequency  standards over short distances,
- • remote comparison techniques need to be developed at an international level so that optical  frequency standards can be compared,

welcomes

- • the activities of the joint working group of the CCTF and the CCL to review the frequencies  of optically-based representations of the second,
- • the additions made by the CIPM in 2009 to the common list of "Recommended values of  standard frequencies for applications including the practical realization of the metre and  secondary representations of the second",
- • the establishment of a CCTF working group on Coordination of the Development of  Advanced Time and Frequency Transfer Techniques,

recommends that

- • NMIs commit resources to the development of optical frequency standards and their  comparison,
- • the BIPM supports the coordination of an international project with the participation of NMIs,  oriented to the study of the techniques which could serve to compare optical frequency  standards.

### CIPM, 2013

  Updates to the list of standard frequencies (PV, 81, 144)

Recommendation 1

The International Committee for Weights and Measures (CIPM),

considering that

- • a common list of “Recommended values of standard frequencies for applications including  the practical realization of the metre and secondary representations of the second” has  been established,
- • the CCL-CCTF Frequency Standards Working Group (FSWG) has reviewed several  candidates for inclusion into the list,

recommends the following changes to the list of “Recommended values of standard frequencies  for applications including the practical realization of the metre and secondary representations of  the second”:

- • that the following transition frequency be added to the list:
- − the unperturbed optical transition 6s2 1S0 – 6s 6p 3P0 of the 199Hg neutral atom with a  frequency of 1 128 575 290 808 162 Hz and an estimated relative standard uncertainty  of 1.7 × 10−14;
- • that the following transition frequencies be updated in the list:
- − the unperturbed optical transition 4s 2S1/2 – 3d 2D5/2 of the 40Ca+ ion with a frequency of  411 042 129 776 395 Hz and an estimated relative standard uncertainty of 1.5 × 10−14;
- − the unperturbed optical transition 1S – 2S of the 1H neutral atom with a frequency of  1 233 030 706 593 518 Hz and an estimated relative standard uncertainty of  1.2 × 10−14;

Note: This frequency corresponds to half of the energy difference between the 1S and 2S states;

190  •  Appendix 1

- • that the following transition frequencies be updated in the list and endorsed as secondary  representations of the second:
- − the unperturbed optical transition 6s 2S1/2 – 4f13 6s2 2F7/2 of the 171Yb+ ion (octupole)  with a frequency of 642 121 496 772 645.6 Hz and an estimated relative standard  uncertainty of 1.3 × 10−15;
- − the unperturbed optical transition 6s2 1S0 – 6s 6p 3P0 of the 171Yb neutral atom with a  frequency of 518 295 836 590 865.0 Hz and an estimated relative standard uncertainty  of 2.7 × 10−15;
- • that the following transition frequency be added to the list and as a secondary  representation of the second:
- − the unperturbed optical transition 3s2 1S0 – 3s 3p 3P0 of the 27Al+ ion with a frequency of  1 121 015 393 207 857.3 Hz and an estimated relative standard uncertainty of  1.9 × 10−15;
- • that the following transition frequencies be updated in the list and as secondary  representations of the second:
- − the unperturbed optical transition 5d10 6s 2S1/2 – 5d9 6s2 2D5/2 of the 199Hg+ ion with a  frequency of 1 064 721 609 899 145.3 Hz and an estimated relative standard  uncertainty of 1.9 × 10−15;
- − the unperturbed optical transition 6s 2S1/2 (F = 0, mF = 0) – 5d 2D3/2 (F = 2, mF = 0) of  the 171Yb+ ion (quadrupole) with a frequency of 688 358 979 309 307.1 Hz and an  estimated relative standard uncertainty of 3 × 10−15;
- − the unperturbed optical transition 5s 2S1/2 – 4d 2D5/2 of the 88Sr+ ion with a frequency of  444 779 044 095 485.3 Hz and an estimated relative standard uncertainty of  4.0 × 10−15;
- − the unperturbed optical transition 5s2 1S0 – 5s5p 3P0 of the 87Sr neutral atom with a  frequency of 429 228 004 229 873.4 Hz and an estimated relative standard uncertainty  of 1 × 10−15;
- • that the following transition frequency be updated as a secondary representation of the  second:
- − the unperturbed ground - state hyperfine transition of 87Rb with a frequency of  6 834 682 610.904 312 Hz and an estimated relative standard uncertainty of  1.3 × 10−15.

Note: The value of the estimated standard uncertainty is assumed to correspond to a confidence  level of 68 %. However, given the very limited number of available data there is a possibility that  in hindsight this might not prove to be exact.

### 25th CGPM, 2014

  On the future revision of the International System of Units, the SI (CR, 416 and  Metrologia, 2015, 52, 155)

Resolution 1

The General Conference on Weights and Measures (CGPM), at its 25th meeting,

recalling

- • Resolution 1 adopted by the CGPM at its 24th meeting (2011), which takes note of the  intention of the International Committee for Weights and Measures (CIPM) to propose a  revision of the SI that links the definitions of the kilogram, ampere, kelvin, and mole to exact  numerical values of the Planck constant h, elementary charge e, Boltzmann constant k, and  Avogadro constant NA, respectively, and which revises the way the SI is defined including the  wording of the definitions of the SI units for time, length, mass, electric current,  thermodynamic temperature, amount of substance, and luminous intensity so that the  reference constants on which the SI is based are clearly apparent,
- • the many benefits summarized in Resolution 1 that will accrue to science, technology,  industry, and commerce from such a revision, especially from linking the kilogram to an  invariant of nature rather than to the mass of a material artefact, thereby ensuring its long- term stability,

Appendix 1  •  191

- • Resolution 7 adopted by the CGPM at its 21st meeting (1999), which encourages work at the  National Metrology Institutes (NMIs) that can lead to such a redefinition of the kilogram,
- • Resolution 12 adopted by the CGPM at its 23rd meeting (2007), which outlines the work that  should be carried out by the NMIs, the International Bureau of Weights and Measures  (BIPM), and the CIPM together with its Consultative Committees (CCs) that could enable the  planned revision of the SI to be adopted by the CGPM,

considering that there has been significant progress in completing the necessary work,  including

- • the acquisition of relevant data and their analysis by the Committee on Data for Science and  Technology (CODATA) to obtain the required values of h, e, k, and NA,
- • establishment by the BIPM of an ensemble of reference standards of mass to facilitate the  dissemination of the unit of mass in the revised SI,
- • the preparation of mises-en-pratique for the new definitions of the kilogram, ampere, kelvin,  and mole,

noting that further work by the Consultative Committee for Units (CCU), the CIPM, the BIPM,  the NMIs and the CCs should focus on

- • awareness campaigns to alert user communities as well as the general public to the proposed  revision of the SI,
- • the preparation of the 9th edition of the SI Brochure that presents the revised SI in a way that  can be understood by a diverse readership without compromising scientific rigour,

that despite this progress the data do not yet appear to be sufficiently robust for the CGPM to  adopt the revised SI at its 25th meeting,

encourages

- • continued effort in the NMIs, the BIPM, and academic institutions to obtain data relevant to  the determination of h, e, k, and NA with the requisite uncertainties,
- • the NMIs to continue acting through the CCs to discuss and review this data,
- • the CIPM to continue developing a plan to provide the path via the Consultative Committees  and the CCU for implementing Resolution 1 adopted by the CGPM at its 24th meeting (2011),  and
- • continued effort by the CIPM, together with its Consultative Committees, the NMIs, the BIPM,  and other organizations such as the International Organization of Legal Metrology (OIML), to  complete all work necessary for the CGPM at its 26th meeting to adopt a resolution that  would replace the current SI with the revised SI, provided the amount of data, their  uncertainties, and level of consistency are deemed satisfactory.

Note: The 26th CGPM in 2018 (Resolution 1, see p. 194) finally approved the revision of  the SI.

### CIPM, 2015

  Updates to the list of standard frequencies (PV, 83, 207)

Recommendation 2

The International Committee for Weights and Measures (CIPM),

considering

- • a common list of “Recommended values of standard frequencies for applications including  the practical realization of the metre and secondary representations of the second” has  been established,
- • the CCL-CCTF Frequency Standards Working Group (WGFS) has reviewed several  candidates for updating the list,

recommends

that the following transition frequencies shall be updated in the list of recommended values of  standard frequencies:

192  •  Appendix 1

- • the unperturbed optical transition 6s2 1S0 – 6s6p 3P0 of the 199Hg neutral atom with a  frequency of f199Hg = 1 128 575 290 808 154.8 Hz and an estimated relative standard  uncertainty of 6 × 10−16;
- • the unperturbed optical transition 6s 2S1/2 – 4f13 6s2 2F7/2 of the 171Yb+ ion with a frequency  of f171Yb+ (octupole) = 642 121 496 772 645.0 Hz and an estimated relative standard  uncertainty of 6 × 10−16 (this radiation is already endorsed by the CIPM as a secondary  representation of the second);
- • the unperturbed optical transition 6s 2S1/2 (F = 0, mF = 0) – 5d 2D3/2 (F = 2, mF = 0) of the  171Yb+ ion with a frequency of f171Yb+ (quadrupole) = 688 358 979 309 308.3 Hz and an  estimated relative standard uncertainty of 6 × 10−16 (this radiation is already endorsed by  the CIPM as a secondary representation of the second);
- • the unperturbed optical transition 5s 2S1/2 – 4d 2D5/2 of the 88Sr+ ion with a frequency of  f88Sr+ = 444 779 044 095 486.6 Hz and an estimated relative standard uncertainty of  1.6 × 10−15 (this radiation is already endorsed by the CIPM as a secondary representation of  the second);
- • the unperturbed optical transition 4s 2S1/2 – 3d 2D5/2 of the 40Ca+ ion with a frequency of  f40Ca+ = 411 042 129 776 398.4 Hz and an estimated relative standard uncertainty of  1.2 × 10−14;
- • the unperturbed optical transition 1S – 2S of the 1H neutral atom with a frequency of  f1H = 1 233 030 706 593 514 Hz and an estimated relative standard uncertainty of 9 × 10−15.

Note: This frequency corresponds to half of the energy difference between the 1S and 2S states;

- • the unperturbed optical transition 5s2 1S0 – 5s5p 3P0 of the 87Sr neutral atom with a  frequency of f87Sr = 429 228 004 229 873.2 Hz and an estimated relative standard  uncertainty of 5 × 10−16 (this radiation is already endorsed by the CIPM as a secondary  representation of the second);
- • the unperturbed optical transition 6s2 1S0 – 6s6p 3P0 of the 171Yb neutral atom with a  frequency of f171Yb = 518 295 836 590 864.0 Hz and an estimated relative standard  uncertainty of 2 × 10−15 (this radiation is already endorsed by the CIPM as a secondary  representation of the second);
- • the unperturbed ground-state hyperfine transition of 87Rb with a frequency of  f87Rb = 6 834 682 610.904 310 Hz and an estimated relative standard uncertainty of  7 × 10−16 (this radiation is already endorsed by the CIPM as a secondary representation of  the second).

and also recommends

that the following transition frequencies shall be included in the list of recommended values of  standard frequencies:

• Absorbing molecule 127I2, saturated absorption a1 component, R(36) 32-0 transition.

The values  fa1 = 564 074 632.42 MHz

λa1 = 531 476 582.65 fm

with an estimated relative standard uncertainty of 1 × 10−10 apply to the radiation of a frequency- doubled diode DFB laser, stabilized with an iodine cell external to the laser.

• Absorbing atom 87Rb 5S1/2 - 5P3/2 crossover between the d and f hyperfine components  of the saturated absorption at 780 nm (D2 transition)

The values  fd/f crossover = 384 227 981.9 MHz

λd/f crossover = 780 246 291.6 fm

with an estimated relative standard uncertainty of 5 × 10−10 apply to the radiation of a tunable  External Cavity Diode Laser, stabilized to the d/f crossover in a rubidium cell external to the laser.

Note: The value of the standard uncertainty is assumed to correspond to a confidence level of  68 %. However, given the limited availability of data there is a possibility that in hindsight this  might not prove to be exact

Note: Further updates are available on the BIPM website.

Appendix 1  •  193

### CIPM, 2017

  On progress towards the possible redefinition of the SI (PV, 85, 101)

Decision 10

The International Committee for Weights and Measures (CIPM) welcomed recommendations  regarding the redefinition of the SI from its Consultative Committees.

The CIPM noted that the agreed conditions for the redefinition are now met and decided to  submit draft Resolution A to the 26th meeting of the General Conference on Weights and  Measures (CGPM) and to undertake all other necessary steps to proceed with the planned  redefinition of the kilogram, ampere, kelvin and mole.

### 26th CGPM, 2018

  On the revision of the International System of Units, the SI (CR, 472 and  Metrologia, 2019, 56, 022001)

Resolution 1

The General Conference on Weights and Measures (CGPM), at its 26th meeting,

considering

- • the essential requirement for an International System of Units (SI) that is uniform and  accessible world-wide for international trade, high-technology manufacturing, human  health and safety, protection of the environment, global climate studies and the basic  science that underpins all these,
- • that the SI units must be stable in the long term, internally self-consistent and practically  realizable being based on the present theoretical description of nature at the highest  level,
- • that a revision of the SI to meet these requirements was described in Resolution 1 of the  24th General Conference in 2011, adopted unanimously, that laid out in detail a new  way of defining the SI based on a set of seven defining constants, drawn from the  fundamental constants of physics and other constants of nature, from which the  definitions of the seven base units are deduced,
- • that the conditions set by the 24th General Conference, confirmed by the 25th General  Conference, before such a revised SI could be adopted have now been met,

decides

that, effective from 20 May 2019, the International System of Units, the SI, is the system of units  in which

- • the unperturbed ground state hyperfine transition frequency of the caesium 133  atom ∆νCs is 9 192 631 770 Hz,
- • the speed of light in vacuum c is 299 792 458 m/s,
- • the Planck constant h is 6.626 070 15 × 10−34 J s,
- • the elementary charge e is 1.602 176 634 × 10−19 C,
- • the Boltzmann constant k is 1.380 649 × 10−23 J/K,
- • the Avogadro constant NA is 6.022 140 76 × 1023 mol−1,
- • the luminous efficacy of monochromatic radiation of frequency 540 × 1012 Hz, Kcd,  is 683 lm/W,

where the hertz, joule, coulomb, lumen, and watt, with unit symbols Hz, J, C, lm, and W,  respectively, are related to the units second, metre, kilogram, ampere, kelvin, mole, and candela,  with unit symbols s, m, kg, A, K, mol, and cd, respectively, according to Hz = s–1, J = kg m2 s–2,  C = A s, lm = cd m2 m –2 = cd sr, and W = kg m2 s–3.

In making this decision, the General Conference notes the consequences as set out in  Resolution 1 of the 24th General Conference in respect to the base units of the SI and confirms  these in the following Appendices to this Resolution, which have the same force as the  Resolution itself.

194  •  Appendix 1

The General Conference invites the International Committee to produce a new edition of its  Brochure The International System of Units, SI in which a full description of the SI is given.

Appendix 1. Abrogation of former definitions of the base units:

It follows from the new definition of the SI adopted above that

- • the definition of the second in force since 1967/68 (13th meeting of the CGPM,  Resolution 1) is abrogated,
- • the definition of the metre in force since 1983 (17th meeting of the CGPM, Resolution 1),  is abrogated,
- • the definition of the kilogram in force since 1889 (1st meeting of the CGPM, 1889,  3rd meeting of the CGPM, 1901) based upon the mass of the international prototype of  the kilogram is abrogated,
- • the definition of the ampere in force since 1948 (9th meeting of the CGPM) based upon  the definition proposed by the International Committee (CIPM, 1946, Resolution 2) is  abrogated,
- • the definition of the kelvin in force since 1967/68 (13th meeting of the CGPM,  Resolution 4) is abrogated,
- • the definition of the mole in force since 1971 (14th meeting of the CGPM, Resolution 3) is  abrogated,
- • the definition of the candela in force since 1979 (16th meeting of the CGPM, Resolution 3)  is abrogated,
- • the decision to adopt the conventional values of the Josephson constant KJ–90 and of the  von Klitzing constant RK–90 taken by the International Committee (CIPM, 1988,  Recommendations 1 and 2) at the request of the General Conference (18th meeting of  the CGPM, 1987, Resolution 6) for the establishment of representations of the volt and  the ohm using the Josephson and quantum Hall effects, respectively, is abrogated.

Appendix 2. Status of constants previously used in the former definitions:

It follows from the new definition of the SI adopted above, and from the recommended values of  the 2017 special CODATA adjustment on which the values of the defining constants are based,  that at the time this Resolution was adopted

- • the mass of the international prototype of the kilogram m(K) is equal to 1 kg within a  relative standard uncertainty equal to that of the recommended value of h at the time  this Resolution was adopted, namely 1.0 × 10–8 and that in the future its value will be  determined experimentally,
- • the vacuum magnetic permeability µ0 is equal to 4π × 10–7 H m–1 within a relative  standard uncertainty equal to that of the recommended value of the fine-structure  constant α at the time this Resolution was adopted, namely 2.3 × 10−10 and that in the  future its value will be determined experimentally,
- • the thermodynamic temperature of the triple point of water TTPW is equal to 273.16 K  within a relative standard uncertainty closely equal to that of the recommended value of  k at the time this Resolution was adopted, namely 3.7 × 10−7, and that in the future its  value will be determined experimentally,
- • the molar mass of carbon 12, M(12C), is equal to 0.012 kg mol–1 within a relative  standard uncertainty equal to that of the recommended value of NAh at the time this  Resolution was adopted, namely 4.5 × 10−10, and that in the future its value will be  determined experimentally.

Appendix 3. The base units of the SI

Starting from the definition of the SI adopted above in terms of fixed numerical values of the  defining constants, definitions of each of the seven base units are deduced by taking, as  appropriate, one or more of these defining constants to give the following set of definitions:

Appendix 1  •  195

- • The second, symbol s, is the SI unit of time. It is defined by taking the fixed numerical  value of the caesium frequency ∆νCs, the unperturbed ground-state hyperfine transition  frequency of the caesium 133 atom, to be 9 192 631 770 when expressed in the unit Hz,  which is equal to s–1.
- • The metre, symbol m, is the SI unit of length. It is defined by taking the fixed numerical  value of the speed of light in vacuum c to be 299 792 458 when expressed in the unit m/s,  where the second is defined in terms of the caesium frequency ∆νCs.
- • The kilogram, symbol kg, is the SI unit of mass. It is defined by taking the fixed numerical  value of the Planck constant h to be 6.626 070 15 × 10–34 when expressed in the unit J s,  which is equal to kg m2 s–1, where the metre and the second are defined in terms of c and  ∆νCs.
- • The ampere, symbol A, is the SI unit of electric current. It is defined by taking the fixed  numerical value of the elementary charge e to be 1.602 176 634 × 10–19 when expressed  in the unit C, which is equal to A s, where the second is defined in terms of ∆νCs.
- • The kelvin, symbol K, is the SI unit of thermodynamic temperature. It is defined by taking the  fixed numerical value of the Boltzmann constant k to be 1.380 649 × 10– 23 when expressed  in the unit J K–1, which is equal to kg m2 s–2 K–1, where the kilogram, metre and second are  defined in terms of h, c and ∆νCs.
- • The mole, symbol mol, is the SI unit of amount of substance. One mole contains exactly  6.022 140 76 × 1023 elementary entities. This number is the fixed numerical value of the  Avogadro constant, NA, when expressed in the unit mol−1 and is called the Avogadro  number.

The amount of substance, symbol n, of a system is a measure of the number of specified  elementary entities. An elementary entity may be an atom, a molecule, an ion, an  electron, any other particle or specified group of particles.

- • The candela, symbol cd, is the SI unit of luminous intensity in a given direction. It is defined  by taking the fixed numerical value of the luminous efficacy of monochromatic radiation of  frequency 540 × 1012 Hz, Kcd, to be 683 when expressed in the unit lm W–1, which is equal to  cd sr W–1, or cd sr kg–1 m–2 s3, where the kilogram, metre and second are defined in terms of  h, c and ∆νCs.

### 27th CGPM, 2022

  On the extension of the range of SI prefixes (CR, 397 and Metrologia, 2023, 60,  013001)

Resolution 3

The General Conference on Weights and Measures (CGPM), at its 27th meeting,

recalling

that decisions were made at previous meetings when it was considered timely to extend the  range of SI prefixes including Resolution 12 (paragraph 3) adopted by the CGPM at its  11th meeting (1960), Resolution 8 adopted by the CGPM at its 12th meeting (1964),  Resolution 10 adopted by the CGPM at its 15th meeting (1975), and Resolution 4 adopted by  the CGPM at its 19th meeting (1991),

considering

- − the essential role of the International System of Units (SI) in providing confidence in the  accuracy and global comparability of measurements needed for international trade,  manufacturing, human health and safety, protection of the environment, global climate  studies and scientific research,
- − the benefits of encouraging the use of SI units by providing new SI prefixes for scientific  communities that depend on measurements that are not covered by the current range,

196  •  Appendix 1

- − the needs of data science in the near future to express quantities of digital information  using orders of magnitude in excess of 1024,
- − the importance of timely action to prevent unofficial prefix names being de facto adopted in  other communities,

decides

to add to the list of SI prefixes to be used for multiples and submultiples of units the  following prefixes:

||
|---|
||
||
||
||

Multiplying factor

Name

Symbol

1027

ronna

R

10−27

ronto

r

1030

quetta

Q

10−30

quecto

q

Appendix 1  •  197

# Appendix 2.  Practical realization of the definitions of  some important units

# Appendix 2 is published in electronic form only, and is available on the BIPM website  (www.bipm.org).

198  •  Appendix 2

# Appendix 3.  Units for photochemical  and photobiological quantities

Appendix 3 is published in electronic form only, and is available on the BIPM website  (www.bipm.org).

Appendix 3  •  199

# Appendix 4.  Historical notes on the development of the  International System of Units and its base  units

Part 1. The historical development of the realization of SI units

Experimental methods used for the realization of units and which use equations of physics  are known as primary methods. The essential characteristic of a primary method is that it  allows a quantity to be measured in a particular unit directly from its definition by using  only quantities and constants that themselves do not contain that unit.

Traditionally, a unit for a given quantity was taken to be a particular example of that  quantity, which was chosen to provide numerical values of common measurements of a  convenient size. Before the rise of modern science, units were necessarily defined in terms  of material artefacts, notably the metre and kilogram for length and mass, or the property of  a particular object, namely the rotation of the earth for the second. Even at the origin of the  metric system at the end of the 18th century it was recognized that a more desirable  definition of a unit of length for example would be one based on a universal property of  nature such as the length of a pendulum beating seconds. Such a definition would be  independent of time and place and would in principle be accessible all over the world. At  the time, practical considerations resulted in the simpler, artefact definitions for the metre  and the kilogram and the second remained linked to the rotation of the Earth. It was only in  1960 that the first non-material definition was adopted, namely the wavelength of a  specified optical radiation for the metre.

Since then, definitions of the ampere, kelvin, mole and candela have been adopted that do  not refer to material artefacts. In the case of the ampere it refers to a specified electric  current required to produce a given electromagnetic force and, in the case of the kelvin, to a  particular thermodynamic state, namely the triple point of water. Even the atomic definition  of the second was in terms of a specified transition of the caesium atom. The kilogram has  always stood out as the one unit that had resisted the transformation from an artefact. The  definition that opened the way to real universality was that of the metre in 1983.  This definition implied, although it did not state, a fixed numerical value for the speed of  light. The definition was worded, however, in the traditional form and stated essentially that  the metre was the distance travelled by light in a specified time. In this way it reflected the  other definitions of the base units of the SI each of which has the same form, for example  “the ampere is the current which…” and “the kelvin is a fraction of a specified  temperature”. Such definitions can be called explicit unit definitions.

Although these definitions meet many of the requirements for universality and accessibility,  and a variety of realizations are often possible, they nevertheless constrain practical  realizations to experiments that are directly or indirectly linked to the particular conditions  or states specified in each definition. In consequence, the accuracy of realization of such  definitions can never be better than the accuracy of realization of the particular conditions  or states specified in the definitions.

200  •  Appendix 4

This is a particular problem with the present definition of the second, which is based on a  microwave transition of an atom of caesium. Frequencies of optical transitions of different  atoms or ions are now demonstrably more reproducible, by some orders of magnitude, than  the defined frequency of caesium.

In the present definition of the SI based on the set of defining constants, instead of each  definition specifying a particular condition or state, which sets a fundamental limit to the  accuracy of realization, any convenient equation of physics that links the particular constant  or constants to the quantity we want to measure may be used. This is a much more general  way of defining the basic units of measurement. It is one that is not limited by today’s  science or technology as future developments may lead to as yet unknown equations that  could result in different ways of realizing units with a much higher accuracy. When defined  in this way, there is, in principle, no limit to the accuracy with which a unit can be realized.  The exception remains the definition of the second in which the original microwave  transition of caesium remains, for the time being, the basis of the definition.

The difference between an explicit unit and an explicit constant definition can be clearly  illustrated using the two previous definitions of the metre that depended upon a fixed  numerical value of the speed of light and secondly the two definitions of the kelvin.  The original 1983 definition of the metre states, in effect, that “the metre is the length of the  path travelled by light in vacuum during a time interval of 1/299 792 458 of a second”. The  new definition simply states that the metre is defined by taking the constant that defines the  second, the specified caesium frequency and the fixed numerical value of the speed of light  expressed in units m s−1. We can thus use any equation of physics including, of course, that  indicated by the former definition, the time taken to travel the given distance which is used  for astronomical distances, but also the simple equation relating frequency and wavelength  to the speed of light. The former definition of the kelvin based on a fixed numerical value  for the temperature of the triple point of water requires ultimately a measurement at the  triple point of water. The new definition, based on the fixed numerical value for the  Boltzmann constant, is much more general in that any thermodynamic equation in which k  appears can in principle be used to determine a thermodynamic temperature at any point on  the temperature scale. For example, by determining the total radiant exitance of a black  body at temperature T, equal to (2π5k4/15c2h3) T4, in W m−2 we can determine T directly.

For the kilogram, the unit whose definition has undergone the most fundamental change,  realization can be through any equation of physics that links mass, the Planck constant, the  velocity of light and the caesium frequency. One such equation is that which describes the  operation of an electro-mechanical balance, previously known as a watt balance, more  recently known as a Kibble1 balance. With this apparatus, a mechanical power, measured in  terms of a mass, m, the local acceleration due to gravity, g, and a velocity, v, can be  measured in terms of an electrical power measured in terms of an electric current and  voltage measured in terms of the quantum Hall and Josephson effects respectively.  The resulting equation is mgv = Ch where C is a calibration constant that includes measured  frequencies and h is Planck’s constant.

1 To recognize Bryan Kibble’s invention of the watt balance

Another method that can be used for a primary realization of the kilogram is through the  determination of the number of atoms in a silicon sphere and using the equation:  𝑚𝑚 =   8𝑉𝑉 𝑎𝑎03 2𝑅𝑅∞ℎ 𝑐𝑐𝛼𝛼2 𝑚𝑚Si 𝑚𝑚e

Appendix 4  •  201

with the mass m and volume V of the sphere (about 1 kg), lattice parameter a0, Rydberg  constant R∞, fine structure constant α, and the masses of a silicon atom (averaged over the  three isotopes used for the sphere) mSi, and the electron me, respectively. The first fraction  corresponds to the number of atoms in the sphere, the second to the electron mass and the  third fraction is the ratio of the mass of the (isotopically averaged) silicon atom to the  electron mass.

Another possibility for measuring mass through the new definition, but this time at the  microscopic level, is through measurements of atomic recoil using the relation that includes  h/m.

All these provide a striking illustration of the generality of the new way of defining units.  Detailed information on the current realization of the base and other units is given on the  BIPM website.

Part 2. The historical development of the International System

The 9th CGPM (1948, Resolution 6; CR 64) instructed the CIPM:

- • to study the establishment of a complete set of rules for units of measurement;
- • to find out for this purpose, by official enquiry, the opinion prevailing in scientific,  technical and educational circles in all countries;
- • to make recommendations on the establishment of a practical system of units of  measurement suitable for adoption by all signatories to the Metre Convention.

The same CGPM also laid down, in Resolution 7 (CR 70), ‘general principles for the  writing of unit symbols’ and listed some coherent derived units that were assigned special  names.

The 10th CGPM (1954, Resolution 6; CR 80) adopted as base quantities and units for this  practical system the following six quantities: length, mass, time, electric current,  thermodynamic temperature and luminous intensity, as well as the six corresponding base  units: metre, kilogram, second, ampere, kelvin and candela. After a lengthy discussion  between physicists and chemists, the 14th CGPM (1971, Resolution 3, CR 78 and  Metrologia 1972, 8, 36) added amount of substance, unit mole, as the seventh base quantity  and unit.

The 11th CGPM (1960, Resolution 12; CR 87) adopted the name Système international  d’unités, with the international abbreviation SI, for this practical system of units and laid  down rules for prefixes, derived units and the former supplementary units, as well as other  matters; it thus established a comprehensive specification for units of measurement.  Subsequent meetings of the CGPM and the CIPM have added to and modified the original  structure of the SI to take account of advances in science and of the changing needs of  users.

The historical sequence that led to these important decisions may be summarized as  follows.

- • The creation of the decimal metric system at the time of the French Revolution and  the subsequent deposition of two platinum standards representing the metre and the  kilogram, on 22 June 1799, in the Archives de la République in Paris, which can be  seen as the first step that led to the present International System of Units.

202  •  Appendix 4

- • In 1832, Gauss strongly promoted the application of this metric system, together  with the second defined in astronomy, as a coherent system of units for the physical  sciences. Gauss was the first to make absolute measurements of the earth’s magnetic  field in terms of a decimal system based on the three mechanical units millimetre,  gram and second for, respectively, the quantities length, mass and time. In later years  Gauss and Weber extended these measurements to include other electrical  phenomena.
- • These applications in the field of electricity and magnetism were further extended in  the 1860s under the active leadership of Maxwell and Thomson through the British  Association for the Advancement of Science (BAAS). They formulated the  requirement for a coherent system of units with base units and derived units. In 1874  the BAAS introduced the CGS system, a three-dimensional coherent unit system  based on the three mechanical units centimetre, gram and second, using prefixes  ranging from micro to mega to express decimal sub-multiples and multiples.  The subsequent development of physics as an experimental science was largely  based on this system.
- • The sizes of the coherent CGS units in the fields of electricity and magnetism proved  to be inconvenient, so in the 1880s the BAAS and the International Electrical  Congress, predecessor of the International Electrotechnical Commission (IEC),  approved a mutually coherent set of practical units. Among them were the ohm for  electrical resistance, the volt for electromotive force, and the ampere for electric  current.
- • After the signing of the Metre Convention on 20 May 1875, which created the BIPM  and established the CGPM and the CIPM, work began on establishing new  international prototypes for the metre and the kilogram. In 1889 the 1st CGPM  sanctioned the international prototypes for the metre and the kilogram. Together with  the astronomical second as the unit of time, these units constituted a  three-dimensional mechanical unit system similar to the CGS system, but with the  base units metre, kilogram and second, known as the MKS system.
- • In 1901 Giorgi showed that it is possible to combine the mechanical units of this  MKS system with the practical electrical units to form a coherent four-dimensional  system by adding to the three base units a fourth unit, of an electrical nature such as  the ampere or the ohm, and also rewriting the equations occurring in  electromagnetism in the so-called rationalized form. Giorgi’s proposal opened the  path to a number of new developments.
- • After the revision of the Metre Convention by the 6th CGPM (1921), which  extended the scope and responsibilities of the BIPM to other fields in physics and the  subsequent creation of the Consultative Committee for Electricity (CCE) by the  7th CGPM (1927), the Giorgi proposal was thoroughly discussed by the IEC, the  International Union of Pure and Applied Physics (IUPAP) and other international  organizations. This led the CCE to propose in 1939 the adoption of a  four-dimensional system based on the metre, kilogram, second and ampere, the  MKSA system, a proposal approved by the CIPM in 1946.
- • Following an international enquiry by the BIPM, which began in 1948, the 10th  CGPM (1954) approved the further introduction of the kelvin and the candela, as  base units for thermodynamic temperature and luminous intensity, respectively.  The name International System of Units, with the abbreviation SI, was given to the

Appendix 4  •  203

- system by the 11th CGPM (1960). Rules for prefixes, derived units, the former  supplementary units as well as other matters were established, thus providing a  comprehensive specification for all units of measurement.
- • At the 14th CGPM (1971) a new base unit, the mole, symbol mol, was adopted for  the quantity amount of substance. This followed a proposal from the International  Organization for Standardization originating in a proposal from the Commission on  Symbols, Units and Nomenclature (SUN Commission) of IUPAP, which was  supported by the International Union for Pure and Applied Chemistry (IUPAC). This  brought the number of base units of the SI to seven.
- • Since then, extraordinary advances have been made in relating SI units to truly  invariant quantities such as the fundamental constants of physics and the properties  of atoms. Recognizing the importance of linking SI units to such invariant quantities,  the 24th CGPM (2011) adopted the principles of a new definition of the SI based on  using a set of seven such constants as references for the definitions. At the time of  the 24th CGPM, experiments to determine their values in terms of the then base units  were not completely consistent but by the time of the 26th CGPM (2018) this had  been achieved and the new definition of the SI was adopted in Resolution 1. This is  the basis of the definition presented in this brochure and it is the simplest and most  fundamental way of defining the SI.
- • The SI was previously defined in terms of seven base units and derived units defined  as products of powers of the base units. The seven base units were chosen for  historical reasons, as the metric system, later the SI, evolved and developed over the  last 130 years. Their choice was not unique, but it has become established and  familiar over the years, not only by providing a framework for describing the SI, but  also for defining the derived units. This role for the base units continues in the  present SI even though the SI itself is now defined in terms of the seven defining  constants. In this brochure therefore, definitions of the seven base units can still be  found but are henceforth based on the seven defining constants: the caesium  hyperfine frequency ΔνCs; the speed of light in vacuum c; the Planck constant h;  elementary charge e; Boltzmann constant k; Avogadro constant NA; and the luminous  efficacy of a defined visible radiation Kcd.

The definitions of the seven base units can be related unambiguously to the numerical  values of the seven defining constants. However, there is not a one-to-one relationship  between the seven defining constants and the seven base units as many of the base units call  upon more than one of the defining constants.

Part 3. Historical perspective on the base units

Unit of time, second

Before 1960, the unit of time, the second, was defined as the fraction 1/86 400 of the mean  solar day. The exact definition of “mean solar day” was left to astronomers. However  measurements showed that irregularities in the rotation of the Earth made this an  unsatisfactory definition. In order to define the unit of time more precisely, the 11th CGPM  (1960, Resolution 9, CR, 86) adopted a definition given by the International Astronomical  Union based on the tropical year 1900. Experimental work, however, had already shown that  an atomic standard of time, based on a transition between two energy levels of an atom or a  molecule, could be realized and reproduced much more accurately. Considering that a very

204  •  Appendix 4

precise definition of the unit of time is indispensable for science and technology, the  13th CGPM (1967-1968, Resolution 1, CR, 103 and Metrologia, 1968, 4, 43) chose a new  definition of the second referenced to the frequency of the ground state hyperfine transition in  the caesium 133 atom. A revised more precise wording of this same definition now in terms  of a fixed numerical value of the unperturbed ground-state hyperfine transition frequency of  the caesium 133 atom, ∆νCs, was adopted in Resolution 1 of the 26th CGPM (2018).

Unit of length, metre

The 1889 definition of the metre, namely, the length of the international prototype of  platinum-iridium, was replaced by the 11th CGPM (1960) using a definition based on the  wavelength of the radiation corresponding to a particular transition in krypton 86. This  change was adopted in order to improve the accuracy with which the definition of the metre  could be realized, this being achieved using an interferometer with a travelling microscope  to measure the optical path difference as the fringes were counted. In turn, this was replaced  in 1983 by the 17th CGPM (Resolution 1, CR, 97, and Metrologia, 1984, 20, 25) with a  definition referenced to the distance that light travels in vacuum in a specified interval of  time. The original international prototype of the metre, which was sanctioned by the 1st  CGPM in 1889 (CR, 34-38), is still kept at the BIPM under conditions specified in 1889. In  order to make clear its dependence on the fixed numerical value of the speed of light, c, the  wording of the definition was changed in Resolution 1 of the 26th CGPM (2018).

Unit of mass, kilogram

The 1889 definition of the kilogram was simply the mass of the international prototype of  the kilogram, an artefact made of platinum-iridium. This was, and still is, kept at the BIPM  under the conditions specified by the 1st CGPM (1889, CR, 34-38) when it sanctioned the  prototype and declared that “this prototype shall henceforth be considered to be the unit of  mass”. Forty similar prototypes were made at about the same time and these were all  machined and polished to have closely the same mass as the international prototype. At the  1st CGPM (1889), after calibration against the international prototype, most of these  “national prototypes” were individually assigned to Member States of the Metre  Convention, and some also to the BIPM. The 3rd CGPM (1901, CR, 70), in a declaration  intended to end the ambiguity in common usage concerning the use of the word “weight”,  confirmed that “the kilogram is the unit of mass; it is equal to the mass of the international  prototype of the kilogram”. The complete version of these declarations appears on p. 70 of  the above-mentioned CGPM proceedings.

By the time of the second verification of national prototypes in 1946 it was found that on  average the masses of these prototypes were diverging from that of the international  prototype. This was confirmed by the third verification carried out from 1989 to 1991, the  median difference being about 25 micrograms for the set of original prototypes sanctioned  by the 1st CGPM (1889). In order to assure the long-term stability of the unit of mass, to  take full advantage of quantum electrical standards and to be of more utility to modern  science, a new definition for the kilogram based on the value of a fundamental constant, for  which purpose the Planck constant h was chosen, was adopted by Resolution 1 of the  26th CGPM (2018).

Appendix 4  •  205

Unit of electric current, ampere

Electric units, called “international units”, for current and resistance were introduced by the  International Electrical Congress held in Chicago in 1893 and definitions of the  “international ampere” and “international ohm” were confirmed by the International  Conference in London in 1908.

By the time of the 8th CGPM (1933) there was a unanimous desire to replace the  “international units” by so-called “absolute units”. However because some laboratories had  not yet completed experiments needed to determine the ratios between the international and  absolute units, the CGPM gave authority to the CIPM to decide at an appropriate time both  these ratios and the date at which the new absolute units would come into effect. The CIPM  did so in 1946 (1946, Resolution 2, PV, 20, 129-137), when it decided that the new units  would come into force on 1 January 1948. In October 1948 the 9th CGPM approved the  decisions taken by the CIPM. The definition of the ampere, chosen by the CIPM, was  referenced to the force between parallel wires carrying an electric current and it had the  effect of fixing the numerical value of the vacuum magnetic permeability μ0 (also called the  magnetic constant). The numerical value of the vacuum electric permittivity ε0 (also called  the electric constant) then became fixed as a consequence of the new definition of the metre  adopted in 1983.

However the 1948 definition of the ampere proved difficult to realize and practical quantum  standards (based on Josephson and quantum-Hall effects), which link both the volt and the  ohm to particular combinations of the Planck constant h and elementary charge e, became  almost universally used as a practical realization of the ampere through Ohm’s law (18th  CGPM (1987), Resolution 6, CR 100). As a consequence, it became natural not only to fix  the numerical value of h to redefine the kilogram, but also to fix the numerical value of e to  redefine the ampere in order to bring the practical quantum electrical standards into exact  agreement with the SI. The present definition based on a fixed numerical value for the  elementary charge, e, was adopted in Resolution 1 of the 26th CGPM (2018).

Unit of thermodynamic temperature, kelvin

The definition of the unit of thermodynamic temperature was given by the 10th CGPM  (1954, Resolution 3; CR 79) which selected the triple point of water, TTPW, as a  fundamental fixed point and assigned to it the temperature 273.16 K, thereby defining the  kelvin. The 13th CGPM (1967-1968, Resolution 3; CR, 104 and Metrologia, 1968, 4, 43)  adopted the name kelvin, symbol K, instead of “degree kelvin”, symbol ºK, for the unit  defined in this way. However, the practical difficulties in realizing this definition, requiring  a sample of pure water of well-defined isotopic composition and the development of new  primary methods of thermometry, led to the adoption of a new definition of the kelvin  based on a fixed numerical value of the Boltzmann constant k. The present definition,  which removed both of these constraints, was adopted in Resolution 1 of the 26th CGPM  (2018).

206  •  Appendix 4

Unit of amount of substance, mole

Following the discovery of the fundamental laws of chemistry, units called, for example,  “gram-atom” and “gram molecule” were used to specify amounts of chemical elements or  compounds. These units had a direct connection with “atomic weights” and “molecular  weights”, which are in fact relative atomic and molecular masses. The first compilations of  “Atomic weights” were originally linked to the atomic weight of oxygen, which was, by  general agreement, taken as being 16. Whereas physicists separated the isotopes in a mass  spectrometer and attributed the value 16 to one of the isotopes of oxygen, chemists  attributed the same value to the (slightly variable) mixture of isotopes 16, 17 and 18, which  for them constituted the naturally occurring element oxygen. An agreement between the  International Union of Pure and Applied Physics (IUPAP) and the International Union of  Pure and Applied Chemistry (IUPAC) brought this duality to an end in 1959-1960.  Physicists and chemists had agreed to assign the value 12, exactly, to the so-called atomic  weight, correctly referred to as the relative atomic mass Ar, of the isotope of carbon with  mass number 12 (carbon 12, 12C). The unified scale thus obtained gives the relative atomic  and molecular masses, also known as the atomic and molecular weights, respectively. This  agreement is unaffected by the redefinition of the mole.

The quantity used by chemists to specify the amount of chemical elements or compounds is  called “amount of substance”. Amount of substance, symbol n, is defined to be proportional  to the number of specified elementary entities N in a sample, the proportionality constant  being a universal constant which is the same for all entities. The proportionality constant is  the reciprocal of the Avogadro constant NA, so that n = N/NA. The unit of amount of  substance is called the mole, symbol mol. Following proposals by the IUPAP, IUPAC and  ISO, the CIPM developed a definition of the mole in 1967 and confirmed it in 1969, by  specifying that the molar mass of carbon 12 should be exactly 0.012 kg/mol. This allowed  the amount of substance nS(X) of any pure sample S of entity X to be determined directly  from the mass of the sample mS and the molar mass M(X) of entity X, the molar mass being  determined from its relative atomic mass Ar (atomic or molecular weight) without the need  for a precise knowledge of the Avogadro constant, by using the relations

nS(X) = mS/M(X), and M(X) = Ar(X) g/mol

Thus, this definition of the mole was dependent on the artefact definition of the kilogram.

The numerical value of the Avogadro constant defined in this way was equal to the number  of atoms in 12 grams of carbon 12. However, because of recent technological advances, this  number is now known with such precision that a simpler and more universal definition of  the mole has become possible, namely, by specifying exactly the number of entities in one  mole of any substance, thus fixing the numerical value of the Avogadro constant. This has  the effect that the new definition of the mole and the value of the Avogadro constant are no  longer dependent on the definition of the kilogram. The distinction between the  fundamentally different quantities ‘amount of substance’ and ‘mass’ is thereby emphasized.  The present definition of the mole based on a fixed numerical value for the Avogadro  constant, NA, was adopted in Resolution 1 of the 26th CGPM (2018).

Appendix 4  •  207

Unit of luminous intensity, candela

The units of luminous intensity, which were based on flame or incandescent filament  standards in use in various countries before 1948, were replaced initially by the “new  candle” based on the luminance of a Planckian radiator (a black body) at the temperature of  freezing platinum. This modification had been prepared by the International Commission  on Illumination (CIE) and by the CIPM before 1937 and the decision was promulgated by  the CIPM in 1946. It was then ratified in 1948 by the 9th CGPM, which adopted a new  international name for this unit, the candela, symbol cd; in 1954 the 10th CGPM  established the candela as a base unit. In 1967 the 13th CGPM (Resolution 5, CR, 104 and  Metrologia, 1968, 4, 43-44) amended this definition.

In 1979, because of the difficulties in realizing a Planck radiator at high temperatures, and  the new possibilities offered by radiometry, i.e. the measurement of optical radiation power,  the 16th CGPM (1979, Resolution 3, CR, 100 and Metrologia,1980, 16, 56) adopted a new  definition of the candela.

The present definition of the candela uses a fixed numerical value for the luminous efficacy  of monochromatic radiation of frequency 540 × 1012 Hz, Kcd, adopted in Resolution 1 of the  26th CGPM (2018).

208  •  Appendix 4

## List of acronyms  used in the present volume

## 1 Acronyms for laboratories, committees and conferences

BAAS British Association for the Advancement of Science

BIPM Bureau international des poids et mesures /  International Bureau of Weights and Measures

CCAUV Comité consultatif de l’acoustique, des ultrasons et des vibrations /  Consultative Committee for Acoustics, Ultrasound and Vibration

CCDS Comité consultatif pour la définition de la seconde /  Consultative Committee for the Definition of the Second, see CCTF

CCE Comité consultatif d’électricité /  Consultative Committee for Electricity, see CCEM

CCEM Comité consultatif d’électricité et magnétisme /  (formerly the CCE) Consultative Committee for Electricity and Magnetism

CCL Comité consultatif des longueurs/Consultative Committee for Length

CCM Comité consultatif pour la masse et les grandeurs apparentées /  Consultative Committee for Mass and Related Quantities

CCPR Comité consultatif de photométrie et radiométrie /  Consultative Committee for Photometry and Radiometry

CCQM Comité consultatif pour la quantité de matière : métrologie en chimie et  biologie / Consultative Committee for Amount of Substance: Metrology in  Chemistry and Biology

CCRI Comité consultatif des rayonnements ionisants /  Consultative Committee for Ionizing Radiation

CCT Comité consultatif de thermométrie /  Consultative Committee for Thermometry

CCTF Comité consultatif du temps et des fréquences /  (formerly the CCDS) Consultative Committee for Time and Frequency

CCU Comité consultatif des unités / Consultative Committee for Units

CGPM Conférence générale des poids et mesures /  General Conference on Weights and Measures

CIPM Comité international des poids et mesures /  International Committee for Weights and Measures

CODATA Committee on Data for Science and Technology

CR Comptes Rendus of the Conférence générale des poids et mesures, CGPM

IAU International Astronomical Union

ICRP International Commission on Radiological Protection

ICRU International Commission on Radiation Units and Measurements

IEC International Electrotechnical Commission

ISO International Organization for Standardization

IUPAC International Union of Pure and Applied Chemistry

IUPAP International Union of Pure and Applied Physics

List of acronyms  •  209

OIML Organisation internationale de métrologie légale / International  Organization of Legal Metrology

PV Procès-Verbaux of the Comité international des poids et mesures, CIPM

SUNAMCO Commission for Symbols, Units, Nomenclature, Atomic Masses and  Fundamental Constants, IUPAP

WHO World Health Organization

## 2 Acronyms for scientific terms

CGS Three-dimensional coherent system of units based on the three mechanical  units: centimetre, gram and second

EPT-76 Échelle provisoire de température de 1976 / Provisional Low Temperature  Scale of 1976

GUM Guide pour l’expression de l’incertitude de mesure / Guide to the  Expression of Uncertainty in Measurement

IPTS-68 International Practical Temperature Scale of 1968

ITS-90 International Temperature Scale of 1990

MKS System of units based on the three mechanical units: metre, kilogram, and  second

MKSA Four-dimensional system of units based on the metre, kilogram, second,  and the ampere

SI Système international d’unités / International System of Units

TAI Temps atomique international / International Atomic Time

TCG Temps-coordonnée géocentrique / Geocentric Coordinated Time

TT Terrestrial Time

UTC Coordinated Universal Time

VSMOW Vienna Standard Mean Ocean Water

210  •  List of acronyms

Pavillon de Breteuil

F-92312 Sèvres Cedex

FRANCE

[bipm.org](http://www.bipm.org/)

© bipm.org, 2026.

[http://www.bipm.org/](http://www.bipm.org/)

- English version

- Copyright statement
- Contents
- Preface to the 9th edition
- 1\. Introduction
- 2\. The International System of Units
- 3\. Decimal multiples and sub-multiples of SI units
- 4\. Non-SI units
- 5\. Writing unit symbols and names, and expressing the values of quantities
- Appendix 1. Decisions of the CGPM and the CIPM
- Appendix 2.  Practical realization of the definitions of some important units
- Appendix 3.  Units for photochemical  and photobiological quantities
- Appendix 4.  Historical notes on the development of the International System of Units and its base units
- List of acronyms